Monitoring systems on historic buildings: The Brunelleschi Dome

被引:23
作者
Bartoli, G [1 ]
Chiarugi, A [1 ]
Gusella, V [1 ]
机构
[1] UNIV PERUGIA,INST ENERGET,I-06125 PERUGIA,ITALY
来源
JOURNAL OF STRUCTURAL ENGINEERING-ASCE | 1996年 / 122卷 / 06期
关键词
D O I
10.1061/(ASCE)0733-9445(1996)122:6(663)
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
A digitally controlled monitoring system has been installed to observe and control the propagation of cracks in the Dome of Santa Maria del Fiore cathedral in Firenze, Italy. This system has been in operation since 1988. This paper describes the Brunelleschi Dome structure, the development of cracks, and the monitoring system. The monitoring of data is evaluated based with an understanding of the structural behavior of the Dome. Presently the behavior is very different than it was earlier because of the presence of the cracks themselves. The correlation between crack width variation and environmental loads is analyzed. A numerical procedure was developed to estimate the trend of the increasing crack mean width. The results are compared to those obtained by the analysis of other monitoring systems previously installed in the Dome and historical data. Some considerations and suggestions about the use of monitoring systems in the field of the structural preservation of historic buildings are also discussed.
引用
收藏
页码:663 / 673
页数:11
相关论文
共 12 条
[1]  
BARBI L, 1983, B INGEGNERI, V9
[2]  
Bendat J.S., 1971, RANDOM DATA ANAL MEA
[3]  
BLASI C, 1984, INCARCOS, V449
[4]  
CASTOLDI A, 1989, QUADERNI ISMES, V262
[5]  
CHIARUGI A, 1990, 1390 DIC STRUCT SECT
[6]  
CHIARUGI A, 1983, IABSE S STRENGTH BUI, P169
[7]  
DELMORO L, 1896, ATT CONS MON TOSC CO
[8]  
GUASTI C, 1857, CUPOLA S MARIA FIORE
[9]  
Ministero per i Beni Culturali e Ambientali Commissione di studio, 1985, RAPP SIT COMPL STRUT
[10]  
*OP DISAND MAR DEL, 1939, REL STUD CUP BRUN ES