Repetitive Control Based Phase Voltage Modulation Amendment for FOC-Based Five-Phase PMSMs Under Single-Phase Open Fault

被引:34
|
作者
Tian, Bing [1 ]
Sun, Li [2 ]
Molinas, Marta [1 ]
An, Qun-Tao [2 ]
机构
[1] Norwegian Univ Sci & Technol, Dept Engn Cybernet, N-7491 Trondheim, Norway
[2] Harbin Inst Technol, Dept Elect Engn, Harbin 150001, Peoples R China
关键词
Circuit faults; Permanent magnet motors; Reluctance motors; Torque; Fault tolerance; Fault tolerant systems; Fault-tolerant control (FTC); five-phase permanent magnet synchronous motor (5Ph PMSM); oscillating neutral; phase voltage modulation (PVM); single-phase open fault; PERMANENT-MAGNET MOTOR; DIRECT TORQUE CONTROL; COMMON-MODE VOLTAGE; TOLERANT CONTROL; PM MACHINE; REDUCTION; RIPPLE; SVPWM; PWM;
D O I
10.1109/TIE.2020.2975502
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
This article investigates the most elementary phase voltage modulation (PVM) for a more generic five-phase permanent magnet synchronous motor drive under a single-phase open fault. Most works on this topic are intended for some specific motor types, and in most cases, it assumes the inverter can still be treated as a linear switching-mode power amplifier. This article figures out that due to an oscillating neutral, the phase voltage is unable to be linearly modulated, which is to say the simplest sinusoidal pulsewidth modulation is problematic to fit a newly developed well-decoupled model under single-phase open fault. To this end, a nonlinear transform incorporating the faulty phase voltage is theoretically proposed, which alleviates the influence of oscillating neutral on PVM, and several approaches to cancel the need for phase voltage sensors are comparatively investigated. Accordingly, the PVM with repetitive control and back electromotive force compensation is put forward to fix the "faulty inverter" in practice. Plausible PVM approaches are tested experimentally, and the superiority of the proposed PVM is confirmed by experimental results.
引用
收藏
页码:1949 / 1960
页数:12
相关论文
共 50 条
  • [41] Sensorless Vector Control of Five-phase Induction Motor under Open-phases Fault
    Kong, Wubin
    Huang, Jin
    Li, Bingnan
    Zhao, LiHang
    ELECTRIC POWER COMPONENTS AND SYSTEMS, 2014, 42 (10) : 1039 - 1047
  • [42] A novel DTC scheme for a sensorless five-phase IM drive under open-phase fault
    Echeikh, Hamdi
    Kesraoui, Hichem
    Trabelsi, Ramzi
    Iqbal, Atif
    Mimouni, Mohamed Faouzi
    COMPEL-THE INTERNATIONAL JOURNAL FOR COMPUTATION AND MATHEMATICS IN ELECTRICAL AND ELECTRONIC ENGINEERING, 2019, 38 (02) : 829 - 844
  • [43] A Modulation Method Based on a Generalised Solution of the Five-Phase Voltage-Time Law
    Riveros, Jose A.
    Rivera, Marco
    Prieto, Joel
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2021, 68 (08) : 6434 - 6443
  • [44] Fault-Tolerant Current Predictive Control of Five-Phase Induction Motor Drives with an Open Phase
    Guzman, H.
    Duran, M. J.
    Barrero, F.
    Toral, S.
    IECON 2011: 37TH ANNUAL CONFERENCE ON IEEE INDUSTRIAL ELECTRONICS SOCIETY, 2011, : 3680 - 3685
  • [45] Sensorless speed control of a five-phase induction machine under open-phase condition
    Morsy, Ahmed S.
    Abdelkhalik, Ayman S.
    Ahmed, Shehab
    Massoud, Ahmed Mohamed
    JOURNAL OF ENGINEERING-JOE, 2014,
  • [46] Two-phase open-circuit multi-vectors model predictive fault-tolerant control for five-phase IPMSM based on voltage errors
    Liu G.-H.
    Wang X.
    Chen Q.
    Chen S.-L.
    Fu L.-Q.
    Xia Y.-H.
    Kongzhi yu Juece/Control and Decision, 2024, 39 (01): : 196 - 205
  • [47] Current Control for Single-Inverter-Fed Series-Connected Five-phase PMSMs
    Chen, Hung-Chi
    Su, Chong-Xian
    2013 IEEE INTERNATIONAL SYMPOSIUM ON INDUSTRIAL ELECTRONICS (ISIE), 2013,
  • [48] Single Line/Phase Open Fault-Tolerant Decoupling Control of a Five-Phase Permanent Magnet Synchronous Motor under Different Stator Connections
    Tian, Bing
    Lu, Runze
    Hu, Jiasongyu
    ENERGIES, 2022, 15 (09)
  • [49] Optimal Fault Tolerant Control of Five-Phase Permanent Magnet Synchronous Motor Under One-Phase Open-Circuit Fault
    Jie, Song
    PROCEEDINGS OF 2019 CHINESE INTELLIGENT AUTOMATION CONFERENCE, 2020, 586 : 156 - 165
  • [50] Online Full Range Copper Loss Minimization for Single-Phase Short-Circuit Fault Tolerant Control in Five-Phase PMSM
    Wang, Huanran
    Gu, Chunyang
    Zhao, Weiduo
    Wang, Shuo
    Zhang, Xiaochen
    Buticchi, Giampaolo
    Gerada, Chris
    Zhang, He
    IEEE TRANSACTIONS ON TRANSPORTATION ELECTRIFICATION, 2024, 10 (02): : 2777 - 2788