Dependability of Posterior-Segment Spectral Domain Optical Coherence Tomography for Measuring Central Corneal Thickness

被引:4
作者
Correa-Perez, Maria E. [1 ,2 ]
Olmo, Natalia [2 ]
Lopez-Miguel, Alberto [1 ]
Fernandez, Itziar [1 ,3 ]
Coco-Martin, Mara B. [1 ]
Maldonado, Miguel J. [1 ]
机构
[1] Univ Valladolid, IOBA, E-47011 Valladolid, Spain
[2] Hosp Inmaculada, Dept Oftalmol, Almeria, Spain
[3] Ctr Invest Biomed Red Bioingn Biomat & Nanomed CI, Valladolid, Spain
关键词
spectral domain optical coherence tomography; central corneal thickness; reliability; accuracy; IN-SITU KERATOMILEUSIS; HIGH MYOPIA; PACHYMETRY; REPRODUCIBILITY; ECTASIA; REPEATABILITY; RISK;
D O I
10.1097/ICO.0000000000000253
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: The aim of this study was to assess the intersession and interobserver reliability of central corneal thickness (CCT) measurements using a posterior-segment spectral domain optical coherence tomography (SD-OCT). Methods: Sixty patients were examined with a posterior-segment SD-OCT system (Topcon 3D-OCT). To analyze intersession reproducibility, 1 examiner measured CCT in 60 eyes 2 times 1 week apart, and to study interobserver reproducibility, a second examiner obtained another measurement during the first session. Within-subject reproducibility, coefficient of reproducibility (CR), and intraclass correlation coefficients (ICC) were calculated. Agreement between Topcon 3D OCT and ultrasound pachymetry (USP) was also assessed. Results: Posterior-segment SD-OCT showed an intersession reproducibility of 12.7 mu m (CR = 2.4%) and an excellent ICC (0.96). No systematic difference between sessions was found (average difference, 1.7 mu m; P = 0.15). We found no significant bias between observers (mean difference, -1.5 mu m; P = 0.29). The interobserver reproducibility was 16.4 mu m (CR = 3.1%), and the ICC was 0.94. Topcon 3D OCT CCT values were lower than USP readings (mean difference, 7.6 +/- 8.1 mu m; 95% confidence interval, 9.9-5.3 mu m; P < 0.001). Conclusions: With a commercially available retinal SD-OCT system, reliable intersession and interobserver CCT measurements can be feasibly obtained. The criteria for a significant change, which would be the one exceeding the reproducibility, indicate that intersession and interobserver variations in CCT of more than 13 and 16 mm, respectively, may reflect true corneal change with this particular device. These estimates should help investigators and clinicians differentiate actual CCT modification from measurement random error. The slight CCT underestimation with respect to USP is within the range of other OCT devices.
引用
收藏
页码:1219 / 1224
页数:6
相关论文
共 26 条
[11]   Central Corneal Thickness Measured With Three Optical Devices and Ultrasound Pachometry [J].
Gonzalez-Perez, Javier ;
Manuel Gonzalez-Meijome, Jose ;
Rodriguez Ares, Maria Teresa ;
Angel Parafita, Manuel .
EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2011, 37 (02) :66-70
[12]  
Gordon MO, 2002, ARCH OPHTHALMOL-CHIC, V120, P714
[13]   Assessment of Artifacts and Reproducibility across Spectral- and Time-Domain Optical Coherence Tomography Devices [J].
Ho, Joseph ;
Sull, Alan C. ;
Vuong, Laurel N. ;
Chen, Yueli ;
Liu, Jonathan ;
Fujimoto, James G. ;
Schuman, Joel S. ;
Duker, Jay S. .
OPHTHALMOLOGY, 2009, 116 (10) :1960-1970
[14]   Intra-examiner repeatability and agreement of corneal pachymetry map measurement by time-domain and Fourier-domain optical coherence tomography [J].
Huang, Jehn-Yu ;
Pekmezci, Melike ;
Yaplee, Stephanie ;
Lin, Shan .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2010, 248 (11) :1647-1656
[15]   Central Corneal Thickness Measurements With Fourier-Domain Optical Coherence Tomography Versus Ultrasonic Pachymetry and Rotating Scheimpflug Camera [J].
Ishibazawa, Akihiro ;
Igarashi, Sho ;
Hanada, Kazuomi ;
Nagaoka, Taiji ;
Ishiko, Satoshi ;
Ito, Haruna ;
Yoshida, Akitoshi .
CORNEA, 2011, 30 (06) :615-619
[16]   Comparative study of central corneal thickness measurement with slit-lamp optical coherence tomography and visante optical coherence tomography [J].
Li, Haitao ;
Leung, Christopher Kai Shun ;
Wong, Lee ;
Cheung, Carol Yim Lui ;
Pang, Chi Pui ;
Weinreb, Robert Neal ;
Lam, Dennis Shun Chiu .
OPHTHALMOLOGY, 2008, 115 (05) :796-801
[17]   Reliability of Noncontact Pachymetry after Laser In Situ Keratomileusis [J].
Maldonado, Miguel J. ;
Lopez-Miguel, Alberto ;
Nieto, Juan C. ;
Cano-Parra, Juan ;
Calvo, Begona ;
Alio, Jorge L. .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2009, 50 (09) :4135-4141
[18]   Corneal epithelial alterations resulting from use of chlorine-disinfected contact tonometer after myopic photorefractive keratectomy [J].
Maldonado, MJ .
OPHTHALMOLOGY, 1998, 105 (08) :1546-1549
[19]   Optical coherence tomography evaluation of the corneal cap and stromal bed features after laser in situ keratomileusis for high myopia and astigmatism [J].
Maldonado, MJ ;
Ruiz-Oblitas, L ;
Munuera, JM ;
Aliseda, D ;
García-Layana, A ;
Moreno-Montañés, J .
OPHTHALMOLOGY, 2000, 107 (01) :81-87
[20]   Reproducibility of retinal thickness measurements in patients with age-related macular degeneration using 3D Fourier-domain optical coherence tomography (OCT) (Topcon 3D-OCT 1000) [J].
Menke, Marcel N. ;
Dabov, Simeon ;
Knecht, Pascal ;
Sturm, Veit .
ACTA OPHTHALMOLOGICA, 2011, 89 (04) :346-351