Improved Ion-Selective Detection Method Using Nanopipette with Poly(vinyl chloride)-Based Membrane

被引:38
作者
Kang, Eun Ji [1 ]
Takami, Tomohide [1 ]
Deng, Xiao Long [1 ]
Son, Jong Wan [1 ]
Kawai, Tomoji [1 ]
Park, Bae Ho [1 ]
机构
[1] Konkuk Univ, Div Quantum Phases & Devices, Dept Phys, Seoul 143701, South Korea
基金
新加坡国家研究基金会;
关键词
MICROSCOPY; ELECTRODES;
D O I
10.1021/jp502715q
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Ion-selective electrodes (ISEs) are widely used to detect targeted ions in solution selectively. Application of an ISE to a small area detection system with a nanopipette requires a special measurement method in order to avoid the enhanced background signal problem caused by a cation-rich layer near the charged inner surface of the nanopipette and the selectivity change problem due to relatively fast saturation of the ISE inside the nanopipette. We developed a novel ion-selective detection system using a nanopipette that measures an alternating current (AC) signal mediated by saturated ionophores in a poly(vinyl chloride) (PVC) membrane located at the conical shank of the nanopipette to solve the above problems. Small but reliable K+ and Na+ ionic current passing through a PVC membrane containing saturated bis(benzo-15-crown-5) and bis(12-crown-4) ionophore, respectively, could be selectively detected using the AC signal measurement system equipped with a lock-in amplifier.
引用
收藏
页码:5130 / 5134
页数:5
相关论文
共 20 条
  • [1] ZnO nanorods as an intracellular sensor for pH measurements
    Al-Hilli, Safaa M.
    Willander, M.
    Ost, Anita
    Stralfors, Peter
    [J]. JOURNAL OF APPLIED PHYSICS, 2007, 102 (08)
  • [2] Scanning electrochemical microscopy. 40. Voltammetric ion-selective micropipet electrodes for probing ion transfer at bilayer lipid membranes
    Amemiya, S
    Bard, AJ
    [J]. ANALYTICAL CHEMISTRY, 2000, 72 (20) : 4940 - 4948
  • [3] Functionalized zinc oxide nanorod with ionophore-membrane coating as an intracellular Ca2+ selective sensor
    Asif, M. H.
    Fulati, A.
    Nur, O.
    Willander, M.
    Brannmark, Cecilia
    Stralfors, Peter
    Borjesson, Sara I.
    Elinder, Fredrik
    [J]. APPLIED PHYSICS LETTERS, 2009, 95 (02)
  • [4] Carrier-based ion-selective electrodes and bulk optodes. 1. General characteristics
    Bakker, E
    Buhlmann, P
    Pretsch, E
    [J]. CHEMICAL REVIEWS, 1997, 97 (08) : 3083 - 3132
  • [5] Ion-Selective Detection by Plasticized Poly(vinyl chloride) Membrane in Glass Nanopipette with Alternating Voltage Modulation
    Deng, Xiao Long
    Takami, Tomohide
    Son, Jong Wan
    Kang, Eun Ji
    Kawai, Tomoji
    Park, Bae Ho
    [J]. JOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY, 2013, 13 (08) : 5413 - 5419
  • [6] Ion Current Oscillation in Glass Nanopipettes
    Deng, Xiao Long
    Takami, Tomohide
    Son, Jong Wan
    Kawai, Tomoji
    Park, Bae Ho
    [J]. JOURNAL OF PHYSICAL CHEMISTRY C, 2012, 116 (28) : 14857 - 14862
  • [7] Selective Measurement of Calcium and Sodium Ion Conductance Using Sub-Micropipette Probes with Ion Filters
    Deng, Xiao Long
    Takami, Tomohide
    Son, Jong Wan
    Kawai, Tomoji
    Park, Bae Ho
    [J]. APPLIED PHYSICS EXPRESS, 2012, 5 (02)
  • [8] THE SCANNING ION-CONDUCTANCE MICROSCOPE
    HANSMA, PK
    DRAKE, B
    MARTI, O
    GOULD, SAC
    PRATER, CB
    [J]. SCIENCE, 1989, 243 (4891) : 641 - 643
  • [9] ION-EXCHANGE AT NEUTRAL CARRIER ION-SELECTIVE ELECTRODE MEMBRANES
    HORVATH, V
    HORVAI, G
    PUNGOR, E
    [J]. FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1993, 346 (6-9): : 569 - 571
  • [10] Novak P, 2009, NAT METHODS, V6, P279, DOI [10.1038/nmeth.1306, 10.1038/NMETH.1306]