Use of a capillary electrophoresis instrument with laser-induced fluorescence detection for DNA quantitation - Comparison of YO-PRO-1 and PicoGreen assays

被引:11
作者
Guillo, C
Ferrance, JP
Landers, JP
机构
[1] Univ Virginia, Dept Chem, Charlottesville, VA 22904 USA
[2] Univ Virginia, Hlth Sci Ctr, Dept Pathol, Charlottesville, VA 22908 USA
关键词
DNA; PicoGreen; YO-PRO-1; laser-induced fluorescence; capillary electrophoresis;
D O I
10.1016/j.chroma.2006.01.111
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Highly selective and sensitive assays are required for detection and quantitation of the small masses of DNA typically encountered in clinical and forensic settings. High detection sensitivity is achieved using fluorescent labeling dyes and detection techniques such as spectrofluorometers, microplate readers and cytometers. This work describes the use of a laser-induced fluorescence (LIF) detector in conjunction with a commercial capillary electrophoresis instrument for DNA quantitation. PicoGreen and YO-PRO-1, two fluorescent DNA labeling dyes, were used to assess the potential of the system for routine DNA analysis. Linearity, reproducibility, sensitivity, limits of detection and quantitation, and sample stability were examined for the two assays. The LIF detector response was found to be linear (R-2 > 0.999) and reproducible (RSD < 9%) in both cases. The PicoGreen assay displayed lower limits of detection and quantitation (20 pg and 60 pg, respectively) than the YO-PRO-1 assay (60 pg and 260 pg, respectively). Although a small variation in fluorescence was observed for the DNA/dye complexes over time, quantitation was not significantly affected and the solutions were found to be relatively stable for 80 min. The advantages of the technique include a 4- to 40-fold reduction in the volume of sample required compared to traditional assays, a 2- to 20-fold reduction in the volume of reagents consumed, fast and automated analysis, and low cost (no specific instrumentation required). (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:239 / 243
页数:5
相关论文
共 31 条
  • [1] Andréasson H, 2003, J FORENSIC SCI, V48, P1280
  • [2] Double-step PCR assay to quantify Epstein-Barr viral load in peripheral blood
    Bergallo, M
    Merlino, C
    Daniele, R
    Sinesi, F
    Fumagalli, M
    Ponzi, AN
    Cavallo, R
    [J]. MOLECULAR BIOTECHNOLOGY, 2004, 27 (03) : 187 - 195
  • [3] Direct determination of single-to-double stranded DNA ratio in solution applying time-resolved fluorescence measurements of dye-DNA complexes
    Cosa, G
    Focsaneanu, KS
    McLean, JRN
    Scaiano, JC
    [J]. CHEMICAL COMMUNICATIONS, 2000, (08) : 689 - 690
  • [4] DNA damage detection technique applying time-resolved fluorescence measurements
    Cosa, G
    Vinette, AL
    McLean, JRN
    Scaiano, JC
    [J]. ANALYTICAL CHEMISTRY, 2002, 74 (24) : 6163 - 6169
  • [5] Cosa G, 2001, PHOTOCHEM PHOTOBIOL, V73, P585, DOI 10.1562/0031-8655(2001)073<0585:PPOFDD>2.0.CO
  • [6] 2
  • [7] Developments toward a complete micro-total analysis system for Duchenne muscular dystrophy diagnosis
    Ferrance, JP
    Wu, QR
    Giordano, B
    Hernandez, C
    Kwok, Y
    Snow, K
    Thibodeau, S
    Landers, JP
    [J]. ANALYTICA CHIMICA ACTA, 2003, 500 (1-2) : 223 - 236
  • [8] Fetal DNA detection in maternal plasma throughout gestation
    Galbiati, S
    Smid, M
    Gambini, D
    Ferrari, A
    Restagno, G
    Viora, E
    Campogrande, M
    Bastonero, S
    Pagliano, M
    Calza, S
    Ferrari, M
    Cremonesi, L
    [J]. HUMAN GENETICS, 2005, 117 (2-3) : 243 - 248
  • [9] Quantitation of DNA from flow cytometry analysis using fluorescent probe
    Higuchi, A
    Murayama, Y
    Tsukamoto, Y
    Kojima, T
    Kitamura, H
    [J]. BULLETIN OF THE CHEMICAL SOCIETY OF JAPAN, 2004, 77 (11) : 2021 - 2025
  • [10] Ingle Jr J. D., 1988, SPECTROCHEMICAL ANAL