Long-term field characterization of tapered element oscillating microbalance and modified tapered element oscillating microbalance samplers in urban and rural New York State locations

被引:20
作者
Schwab, JJ [1 ]
Spicer, J
Demerjian, KL
Ambs, JL
Felton, HD
机构
[1] SUNY Albany, Atmospher Sci Res Ctr, Albany, NY USA
[2] Rupprecht & Patashnick Co Inc, Albany, NY USA
[3] New York State Dept Environm Conservat, Albany, NY USA
关键词
D O I
10.1080/10473289.2004.10470998
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Long-term field comparisons of continuous and integrated filter measurements of mass concentrations of particulate matter (PM) with an aerodynamic diameter less than or equal to 2.5 mum (PM2.5) were performed at rural and urban sites in New York State. Two versions of the continuous tapered element oscillating microbalance (TEOM) mass monitor are deployed at each site, in addition to Federal Reference Method filter samplers. Data are grouped into monthly averages to retain and demonstrate seasonal differences. Strong seasonal dependence is observed-the TEOM monitors with the heated sensors are biased systematically low with respect to the Federal Reference Method measurements during the cold season. For the rural site, the average bias for the sample equilibration system (SES)-equipped and standard TEOM monitors is 14 and 24%, respectively. At this location, the TEOM monitor measurements were biased low for all 34 months. For the urban site, the average bias for the SES and standard TEOM monitors is 8 and 18%, respectively. At this location, the TEOM monitor measurements are as likely to be biased high as low during the warm-season months. The hour averaged data from the two versions of the TEOM monitor are also compared, and also indicate that the SES-equipped version of the TEOM monitor captures 7-11% more PM2.5 mass at these locations.
引用
收藏
页码:1264 / 1280
页数:17
相关论文
共 31 条
[1]   Evaluation of the TEOM(R) method for measurement of ambient particulate mass in urban areas [J].
Allen, G ;
Sioutas, C ;
Koutrakis, P ;
Reiss, R ;
Lurmann, FW ;
Roberts, PT .
JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 1997, 47 (06) :682-689
[2]   Comparison of real-time instruments used to monitor airborne particulate matter [J].
Chung, A ;
Chang, DPY ;
Kleeman, MJ ;
Perry, KD ;
Cahill, TA ;
Dutcher, D ;
McDougall, EM ;
Stroud, K .
JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 2001, 51 (01) :109-120
[3]   ACUTE RESPIRATORY EFFECTS OF PARTICULATE AIR-POLLUTION [J].
DOCKERY, DW ;
POPE, CA .
ANNUAL REVIEW OF PUBLIC HEALTH, 1994, 15 :107-132
[4]   Intercomparison and evaluation of four semi-continuous PM2.5 sulfate instruments [J].
Drewnick, F ;
Schwab, JJ ;
Hogrefe, O ;
Peters, S ;
Husain, L ;
Diamond, D ;
Weber, R ;
Demerjian, KL .
ATMOSPHERIC ENVIRONMENT, 2003, 37 (24) :3335-3350
[5]  
Eatough DJ, 2001, AEROSOL SCI TECH, V34, P1
[6]  
Environmental Protection Agency US, 1998, QUAL ASS HDB AIR POL, V2
[7]  
Health Canada, 2002, HEI PERSP, P1
[8]   Development of an aerosol mass spectrometer for size and composition analysis of submicron particles [J].
Jayne, JT ;
Leard, DC ;
Zhang, XF ;
Davidovits, P ;
Smith, KA ;
Kolb, CE ;
Worsnop, DR .
AEROSOL SCIENCE AND TECHNOLOGY, 2000, 33 (1-2) :49-70
[9]   AIR-POLLUTION AND CAUSE SPECIFIC MORTALITY IN ATHENS [J].
KATSOUYANNI, K ;
KARAKATSANI, A ;
MESSARI, I ;
TOULOUMI, G ;
HATZAKIS, A ;
KALANDIDI, A ;
TRICHOPOULOS, D .
JOURNAL OF EPIDEMIOLOGY AND COMMUNITY HEALTH, 1990, 44 (04) :321-324
[10]   Characterization of PM2.5 and PM10 in the South Coast Air Basin of southern California:: Part 2 -: Temporal variations [J].
Kim, BM ;
Teffera, S ;
Zeldin, MD .
JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 2000, 50 (12) :2045-2059