Comparative Analysis of Existing RC Columns Jacketed with CFRP or FRCC

被引:40
作者
Del Zoppo, Marta [1 ]
Di Ludovico, Marco [2 ]
Balsamo, Alberto [2 ]
Prota, Andrea [2 ]
机构
[1] Univ Naples Parthenope, Dept Engn, I-80143 Naples, Italy
[2] Univ Naples Federico II, Dept Struct Engn & Architecture, I-80125 Naples, Italy
关键词
existing RC columns; CFRP; FRCC; repair; strengthening; seismic retrofit; REINFORCED-CONCRETE COLUMNS; SHEAR-STRENGTH; SEISMIC RETROFIT; DAMAGE MODEL; PERFORMANCE; FRP; MEMBERS;
D O I
10.3390/polym10040361
中图分类号
O63 [高分子化学(高聚物)];
学科分类号
070305 ; 080501 ; 081704 ;
摘要
Reinforced concrete (RC) columns typical of existing structures often exhibit premature failures during seismic events (i.e., longitudinal bars buckling and shear interaction mechanisms) due to the poor quality concrete and the absence of proper seismic details in the potential plastic hinge region. The Fiber Reinforced Polymers (FRP) externally bonded reinforcement is known to be a valid technique to improve the shear capacity or the ductility of existing RC columns. However, few experimental tests have proven its effectiveness in the case of columns affected by shear interaction mechanisms. In this work, the behavior of existing RC columns with border line behavior between flexure and shear have been investigated in the case of poor quality concrete and light FRP strengthening with local jacketing and medium quality concrete and strong FRP strengthening with local jacketing, in order to highlight the effect of concrete strength on the effectiveness of the retrofit intervention. As an alternative to FRP jacketing; the effectiveness of the Fiber Reinforced Cementitious Composite (FRCC) jacketing for the seismic strengthening of columns with highly deteriorated concrete cover or columns already damaged by an earthquake is also evaluated. Six full-scale RC columns have been tested under cyclic loading: one was used as a control specimen; four were strengthened in the potential plastic hinge region with carbon FRP (CFRP); and one was fully jacketed with FRCC. The comparison between poor and medium quality concrete columns showed that the CFRP local jacketing is more effective in the case of poor quality concrete. The FRCC jacketing appears to be a sound repair strategy and a suitable alternative to the FRP jacketing in case of poor quality; however, more experimental research is needed for improving this retrofit technique.
引用
收藏
页数:20
相关论文
共 30 条
[1]  
ACI Committee 318, 2008, 318 ACI COMM, V2007
[2]  
Arani KK, 2014, ACI STRUCT J, V111, P827
[3]   Hysteretic cyclic response of concrete columns reinforced with smooth bars [J].
Arani, Kamyar Karbasi ;
Marefat, Mohammad S. ;
Di Ludovico, Marco ;
Prota, Andrea ;
Manfredi, Gaetano .
BULLETIN OF EARTHQUAKE ENGINEERING, 2013, 11 (06) :2033-2053
[4]   Innovative solution to retrofit RC members: Inhibiting-Repairing-Strengthening (IRS) [J].
Bencardino, Francesco ;
Condello, Antonio .
CONSTRUCTION AND BUILDING MATERIALS, 2016, 117 :171-181
[5]   Column and Joint Retrofitting with High Performance Fiber Reinforced Concrete Jacketing [J].
Beschi, C. ;
Meda, A. ;
Riva, P. .
JOURNAL OF EARTHQUAKE ENGINEERING, 2011, 15 (07) :989-1014
[6]  
Biskinis DE, 2004, ACI STRUCT J, V101, P773
[7]   Models for FRP-wrapped rectangular RC columns with continuous or lap-spliced bars under cyclic lateral loading [J].
Biskinis, Dionysis ;
Fardis, Michael N. .
ENGINEERING STRUCTURES, 2013, 57 :199-212
[8]  
Comite Europeen de Normalisation, 2005, EN19983 COM EUR NORM
[9]  
Del Vecchio C, 2016, REPORT FOTOGRAFICO R
[10]   Comparison of available shear strength models for non-conforming reinforced concrete columns [J].
Del Vecchio, Ciro ;
Del Zoppo, Matta ;
Di Ludovico, Marco ;
Verderame, Gerardo Mario ;
Prota, Andrea .
ENGINEERING STRUCTURES, 2017, 148 :312-327