Pre-Heating Effect on the Microhardness and Depth of Cure of Bulk-Fill Composite Resins

被引:0
作者
Degirmenci, Alperen [1 ]
Can, Dilber Bilgili [1 ]
机构
[1] Univ Van Yuzuncu Yil, Fac Dent, Dept Restorat Dent, Van, Turkey
关键词
Bulk-fill composite; Preheating; Vickers microhardness; Depth of cure; Microhybrid composite; Ormocer; POSTIRRADIATION POLYMERIZATION; MECHANICAL-PROPERTIES; POST-POLYMERIZATION; BIS-GMA; CONVERSION; TEMPERATURE; KINETICS;
D O I
10.15517/IJDS.2021.47209
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
OBJECTIVE: The aim of this study was to investigate the effect of preheating three bulk-fill and one conventional composite resin on the Vickers microhardness and depth of cure of these composites. METHODS: In this study, three bulk-fill composites-SDR Plus (SDR), Estelite BULK FILL Flow (EST), Admira (R) Fusion x-tra (AFX), and one conventional composite resin G-nial POSTERIOR (GP) were used as the control group. The samples were obtained at room temperature (24 degrees C) and at 55 degrees C in T2 mode after being placed in a heating device for 10 minutes. The samples were divided into eight groups (n=10) according to the type of material and heating process that was utilized (preheated and nonheated). All samples were tested with a Vickers microhardness (VHN) tester on the bottom and top surfaces. The first measurements were obtained at baseline; the second set of measurements was performed after the samples were stored in distilled water at 37 degrees C for 24 hours. The depth of cure was calculated using a bottom/top hardness ratio of measurements. Statistical analysis was performed utilizing the SPSS V23 and Shapiro-Wilk tests. Lastly, the Duncan test was used for multiple comparisons (p<0.05). RESULTS: While the VHN increased after the preheating procedure in bulk-fill composites, it decreased in GP. There was no difference between the baseline and the 24-hour VHN values in SDR and GP. After 24 hours, while the VHN of EST increased, the VHN of AFX decreased. There was no difference between the hardness ratios of the AFX and EST samples (p<0.001) and hardness ratios were greater than GP and SDR. CONCLUSION: When comparing the baseline and the 24-hour values, the VHN depended on the type of materials. Sufficient curing depth was obtained in all groups with a thickness of 2mm.
引用
收藏
页码:99 / 112
页数:14
相关论文
共 42 条
  • [1] Polymerization kinetics and impact of post polymerization on the Degree of Conversion of bulk-fill resin-composite at clinically relevant depth
    Al-Ahdal, Khold
    Ilie, Nicoleta
    Silikas, Nick
    Watts, David C.
    [J]. DENTAL MATERIALS, 2015, 31 (10) : 1207 - 1213
  • [2] Alkhudhairy FI, 2017, CLIN COSMET INVESTIG, V9, P1, DOI 10.2147/CCIDE.S130085
  • [3] Post-irradiation hardness development, chemical softening, and thermal stability of bulk-fill and conventional resin-composites
    Alshali, Ruwaida Z.
    Salim, Nesreen A.
    Satterthwaite, Julian D.
    Silikas, Nick
    [J]. JOURNAL OF DENTISTRY, 2015, 43 (02) : 209 - 218
  • [4] Ayub KV, 2014, J CAN DENT ASSOC, V80
  • [5] Bilgili D, 2020, J DENT, V95, DOI 10.1016/j.jdent.2020.103317
  • [6] A prospective randomized clinical trial of one bis-GMA-based and two ormocer-based composite restorative systems in class II cavities: Five-year results
    Bottenberg, P.
    Jacquet, W.
    Alaerts, M.
    Keulemans, F.
    [J]. JOURNAL OF DENTISTRY, 2009, 37 (03) : 198 - 203
  • [7] Light transmittance and micro-mechanical properties of bulk fill vs. conventional resin based composites
    Bucuta, Stefan
    Ilie, Nicoleta
    [J]. CLINICAL ORAL INVESTIGATIONS, 2014, 18 (08) : 1991 - 2000
  • [8] Effect of incremental filling technique on adhesion of light-cured resin composite to cavity floor
    Chikawa, Hirokazu
    Inai, Norimichi
    Cho, Eitetsu
    Kishikawa, Ryuzo
    Otsuki, Masayuki
    Foxton, Richard M.
    Tagami, Junji
    [J]. DENTAL MATERIALS JOURNAL, 2006, 25 (03) : 503 - 508
  • [9] Room-temperature storage of medications labeled for refrigeration
    Cohen, Victor
    Jellinek, Samantha P.
    Teperikidis, Leftherios
    Berkovits, Elliot
    Goldman, William A.
    [J]. AMERICAN JOURNAL OF HEALTH-SYSTEM PHARMACY, 2007, 64 (16) : 1711 - 1715
  • [10] New Resin-Based Bulk-Fill Composites: in vitro Evaluation of Micro-Hardness and Depth of Cure as Infection Risk Indexes
    Colombo, Marco
    Gallo, Simone
    Poggio, Claudio
    Ricaldone, Vittorio
    Arciola, Carla Renata
    Scribante, Andrea
    [J]. MATERIALS, 2020, 13 (06)