Design of the cold atom PHARAO space clock and initial test results

被引:103
作者
Laurent, Ph.
Abgrall, M.
Jentsch, Ch.
Lemonde, P.
Santarelli, G.
Clairon, A.
Maksimovic, I.
Bize, S.
Salomon, Ch.
Blonde, D.
Vega, J. F.
Grosjean, O.
Picard, F.
Saccoccio, M.
Chaubet, M.
Ladiette, N.
Guillet, L.
Zenone, I.
Delaroche, Ch.
Sirmain, Ch.
机构
[1] Lab Kastler Brossel, F-75231 Paris, France
[2] SYRTE, F-75014 Paris, France
[3] CNES, F-31401 Toulouse, France
[4] ALTEN, F-31312 Labege, France
来源
APPLIED PHYSICS B-LASERS AND OPTICS | 2006年 / 84卷 / 04期
关键词
FOUNTAINS; LASER;
D O I
10.1007/s00340-006-2396-6
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
In this paper we describe the cold atom clock PHARAO, designed for microgravity operation. All elements of the PHARAO engineering model have been manufactured and delivered to CNES, the French space agency. We present the clock design, its main characteristics, and initial science operation. PHARAO is one of the main components of the Atomic Clock Ensemble in Space payload that is scheduled to fly on board the International Space Station in 2010.
引用
收藏
页码:683 / 690
页数:8
相关论文
共 8 条
[1]   Automatic system to control the operation of an extended cavity diode laser [J].
Allard, F ;
Maksimovic, I ;
Abgrall, M ;
Laurent, P .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2004, 75 (01) :54-58
[2]  
BAILLARD X, 2006, IN PRESS OPT COMMUN
[3]   Advances in atomic fountains [J].
Bize, S ;
Laurent, P ;
Abgrall, M ;
Marion, H ;
Maksimovic, I ;
Cacciapuoti, L ;
Grünert, J ;
Vian, C ;
dos Santos, FP ;
Rosenbusch, P ;
Lemonde, P ;
Santarelli, G ;
Wolf, P ;
Clairon, A ;
Luiten, A ;
Tobar, M ;
Salomon, C .
COMPTES RENDUS PHYSIQUE, 2004, 5 (08) :829-843
[4]   A CESIUM FOUNTAIN FREQUENCY STANDARD - PRELIMINARY-RESULTS [J].
CLAIRON, A ;
LAURENT, P ;
SANTARELLI, G ;
GHEZALI, S ;
LEA, SN ;
BAHOURA, M .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1995, 44 (02) :128-131
[5]   Cryogenic sapphire oscillator with exceptionally high frequency stability [J].
Mann, AG ;
Sheng, C ;
Luiten, AN .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2001, 50 (02) :519-521
[6]   LASER COOLING OF CESIUM ATOMS BELOW 3-MU-K [J].
SALOMON, C ;
DALIBARD, J ;
PHILLIPS, WD ;
CLAIRON, A ;
GUELLATI, S .
EUROPHYSICS LETTERS, 1990, 12 (08) :683-688
[7]   Cold atoms in space and atomic clocks: ACES [J].
Salomon, C ;
Dimarcq, N ;
Abgrall, M ;
Clairon, A ;
Laurent, P ;
LeMonde, P ;
Santarelli, G ;
Uhrich, P ;
Bernier, LG ;
Busca, G ;
Jornod, A ;
Thomann, P ;
Samain, E ;
Wolf, P ;
Gonzalez, F ;
Guillemot, P ;
Leon, S ;
Nouel, F ;
Sirmain, C ;
Feltham, S .
COMPTES RENDUS DE L ACADEMIE DES SCIENCES SERIE IV PHYSIQUE ASTROPHYSIQUE, 2001, 2 (09) :1313-1330
[8]   BNM-SYRTE fountains: Recent results [J].
Vian, C ;
Rosenbusch, P ;
Marion, H ;
Bize, S ;
Cacciapuoti, L ;
Zhang, S ;
Abgrall, M ;
Chambon, D ;
Maksimovic, I ;
Laurent, P ;
Santarelli, G ;
Clairon, A ;
Luiten, A ;
Tobar, M ;
Salomon, C .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2005, 54 (02) :833-836