On-line headspace-multicapillary column-ion mobility spectrometry hyphenation as a tool for the determination of off-flavours in foods

被引:30
作者
Marquez-Sillero, Isabel [1 ,2 ]
Cardenas, Soledad [1 ]
Sielemann, Stefanie [2 ]
Valcarcel, Miguel [1 ]
机构
[1] Univ Cordoba, Inst Fine Chem & Nanochem, Dept Analyt Chem, E-14071 Cordoba, Spain
[2] Gesell Analyt Sensorsyst mbH, GAS, D-44229 Dortmund, Germany
关键词
Lipid oxidation; Long chain omega-3 polyunsaturated fatty acids; Ion mobility spectrometry; Milk; Linseed oil; Off-flavours; SOLID-PHASE MICROEXTRACTION; MASS-SPECTROMETRY; ELECTRONIC NOSES; EXPLOSIVES; QUALITY; MILK; OIL;
D O I
10.1016/j.chroma.2014.01.062
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In this work, an ion mobility spectrometer (IMS) with a tritium ionization source on-line coupled to a headspace (HS) autosampler and a multicapillary column (MCC) was evaluated for the monitoring of lipid oxidation products in milk with different flavours (cacao, fruits, cereals and nuts) and linseed oil samples enriched with omega-3 acids. In this combination, the multicapillary column is used as an interface between the HS and the IMS, providing the efficient separation of the volatile compounds. In this way, the proposed method permits the detection of hexanal, 2-butanone, acetone and dimethyl sulfide as representative degradation products. The limits of detection were in the interval 0.3 mu gL(-1) (for hexanal in milk) to 3.0 mu gL(-1) (for dimethyl sulfide in linseed oil) while the limits of quantification varied between 1.1 mu gL(-1) (for hexanal in milk) and 9.6 mu gL(-1) (for dimethyl sulfide in linseed oil). The precision of the method was evaluated as relative standard deviation and the values were better than 8% in all cases. The evolution of the volatiles profile during 36 days under different storage conditions (temperature, oxygen and light) demonstrates the capability of the HS-MCC-IMS coupling for the estimation of the degradation of the samples. After the degradation study, it can be concluded that the stability of the milk samples during storage is more affected by the light while temperature was more critical for oil samples. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:99 / 105
页数:7
相关论文
共 29 条
[1]   A review of recent, unconventional applications of ion mobility spectrometry (IMS) [J].
Armenta, Sergio ;
Alcala, Manel ;
Blanco, Marcelo .
ANALYTICA CHIMICA ACTA, 2011, 703 (02) :114-123
[2]   Ion mobility spectrometry: Arriving on site and moving beyond a low profile [J].
Baumbach, JI ;
Eiceman, GA .
APPLIED SPECTROSCOPY, 1999, 53 (09) :338A-355A
[3]   Evaluation of false positive responses by mass spectrometry and ion mobility spectrometry for the detection of trace explosives in complex samples [J].
Crawford, C. L. ;
Hill, H. H., Jr. .
ANALYTICA CHIMICA ACTA, 2013, 795 :36-43
[4]  
Eiceman G., 2005, Ion Mobility Spectrometry, P3
[5]   A critical review of ion mobility spectrometry for the detection of explosives and explosive related compounds [J].
Ewing, RG ;
Atkinson, DA ;
Eiceman, GA ;
Ewing, GJ .
TALANTA, 2001, 54 (03) :515-529
[6]   Fast detection of triacetone triperoxide (TATP) from headspace using planar solid-phase microextraction (PSPME) coupled to an IMS detector [J].
Fan, Wen ;
Young, Mimy ;
Canino, Jon ;
Smith, James ;
Oxley, Jimmie ;
Almirall, Jose R. .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2012, 403 (02) :401-408
[7]  
Frenaille F., 2003, J AGR FOOD CHEM, V51, P2790
[8]   Direct classification of olive oils by using two types of ion mobility spectrometers [J].
Garrido-Delgado, Rocio ;
Mercader-Trejo, Flora ;
Sielemann, Stefanie ;
de Bruyn, Wolfgang ;
Arce, Lourdes ;
Valcarcel, Miguel .
ANALYTICA CHIMICA ACTA, 2011, 696 (1-2) :108-115
[9]   Quality control of raw cows' milk by headspace analysis [J].
Hettinga, K. A. ;
van Valenberg, H. J. F. ;
van Hooijdonk, A. C. M. .
INTERNATIONAL DAIRY JOURNAL, 2008, 18 (05) :506-513
[10]   Health benefits of docosahexaenoic acid (DHA) [J].
Horrocks, LA ;
Yeo, YK .
PHARMACOLOGICAL RESEARCH, 1999, 40 (03) :211-225