A hybrid reconstruction algorithm for fast and accurate 4D cone-beam CT imaginga)

被引:28
作者
Yan, Hao [1 ]
Zhen, Xin [2 ]
Folkerts, Michael [1 ]
Li, Yongbao [1 ,3 ]
Pan, Tinsu [4 ]
Cervino, Laura [5 ]
Jiang, Steve B. [1 ]
Jia, Xun [1 ]
机构
[1] Univ Texas SW Med Ctr Dallas, Dept Radiat Oncol, Dallas, TX 75390 USA
[2] Southern Med Univ, Dept Biomed Engn, Guangzhou 510515, Guangdong, Peoples R China
[3] Tsinghua Univ, Dept Engn Phys, Beijing 100084, Peoples R China
[4] Univ Texas MD Anderson Canc Ctr, Dept Imaging Phys, Houston, TX 77030 USA
[5] Univ Calif San Diego, Dept Radiat Med & Appl Sci, La Jolla, CA 92093 USA
基金
中国国家自然科学基金;
关键词
4D cone beam CT; reconstruction; GPU; PRINCIPAL COMPONENT ANALYSIS; GUIDED RADIATION-THERAPY; LUNG-CANCER RADIOTHERAPY; DEFORMATION FIELD MAP; 3D TUMOR-LOCALIZATION; COMPUTED-TOMOGRAPHY; IMAGE-RECONSTRUCTION; RESPIRATORY MOTION; INTERIOR TOMOGRAPHY; INTRA-FRACTION;
D O I
10.1118/1.4881326
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: 4D cone beam CT (4D-CBCT) has been utilized in radiation therapy to provide 4D image guidance in lung and upper abdomen area. However, clinical application of 4D-CBCT is currently limited due to the long scan time and low image quality. The purpose of this paper is to develop a new 4D-CBCT reconstruction method that restores volumetric images based on the 1-min scan data acquired with a standard 3D-CBCT protocol. Methods: The model optimizes a deformation vector field that deforms a patient-specific planning CT (p-CT), so that the calculated 4D-CBCT projections match measurements. A forward-backward splitting (FBS) method is invented to solve the optimization problem. It splits the original problem into two well-studied subproblems, i.e., image reconstruction and deformable image registration. By iteratively solving the two subproblems, FBS gradually yields correct deformation information, while maintaining high image quality. The whole workflow is implemented on a graphic-processing-unit to improve efficiency. Comprehensive evaluations have been conducted on a moving phantom and three real patient cases regarding the accuracy and quality of the reconstructed images, as well as the algorithm robustness and efficiency. Results: The proposed algorithm reconstructs 4D-CBCT images from highly under-sampled projection data acquired with 1-min scans. Regarding the anatomical structure location accuracy, 0.204 mm average differences and 0.484 mm maximum difference are found for the phantom case, and the maximum differences of 0.3-0.5 mm for patients 1-3 are observed. As for the image quality, intensity errors below 5 and 20 HU compared to the planning CT are achieved for the phantom and the patient cases, respectively. Signal-noise-ratio values are improved by 12.74 and 5.12 times compared to results from FDK algorithm using the 1-min data and 4-min data, respectively. The computation time of the algorithm on a NVIDIA GTX590 card is 1-1.5 min per phase. Conclusions: High-quality 4D-CBCT imaging based on the clinically standard 1-min 3D CBCT scanning protocol is feasible via the proposed hybrid reconstruction algorithm. (C) 2014 American Association of Physicists in Medicine.
引用
收藏
页数:12
相关论文
共 59 条
  • [1] Target-specific optimization of four-dimensional cone beam computed tomography
    Ahmad, Moiz
    Pan, Tinsu
    [J]. MEDICAL PHYSICS, 2012, 39 (09) : 5683 - 5696
  • [2] Four-dimensional volume-of-interest reconstruction for cone-beam computed tomography-guided radiation therapy
    Ahmad, Moiz
    Balter, Peter
    Pan, Tinsu
    [J]. MEDICAL PHYSICS, 2011, 38 (10) : 5646 - 5656
  • [3] Phase II trial of high-dose conformal radiation therapy with concurrent hepatic artery floxuridine for unresectable intrahepatic malignancies
    Ben-Josef, E
    Normalle, D
    Ensminger, WD
    Walker, S
    Tatro, D
    Ten Haken, RK
    Knol, J
    Dawson, LA
    Pan, C
    Lawrence, TS
    [J]. JOURNAL OF CLINICAL ONCOLOGY, 2005, 23 (34) : 8739 - 8747
  • [4] An investigation of 4D cone-beam CT algorithms for slowly rotating scanners
    Bergner, Frank
    Berkus, Timo
    Oelhafen, Markus
    Kunz, Patrik
    Pan, Tinsu
    Grimmer, Rainer
    Ritschl, Ludwig
    Kachelriess, Marc
    [J]. MEDICAL PHYSICS, 2010, 37 (09) : 5044 - 5053
  • [5] Autoadaptive phase-correlated (AAPC) reconstruction for 4D CBCT
    Bergner, Frank
    Berkus, Timo
    Oelhafen, Markus
    Kunz, Patrik
    Pan, Tinsu
    Kachelriess, Marc
    [J]. MEDICAL PHYSICS, 2009, 36 (12) : 5695 - 5706
  • [6] Effects of intra-fraction motion on IMRT dose delivery: statistical analysis and simulation
    Bortfeld, T
    Jokivarsi, K
    Goitein, M
    Kung, J
    Jiang, SB
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (13) : 2203 - 2220
  • [7] Brehm M., 2011, IEEE NUCL SCI UNPUB
  • [8] Reconstruction of a cone-beam CT image via forward iterative projection matching
    Brock, R. Scott
    Docef, Alen
    Murphy, Martin J.
    [J]. MEDICAL PHYSICS, 2010, 37 (12) : 6212 - 6220
  • [9] Prior image constrained compressed sensing (PICCS): A method to accurately reconstruct dynamic CT images from highly undersampled projection data sets
    Chen, Guang-Hong
    Tang, Jie
    Leng, Shuai
    [J]. MEDICAL PHYSICS, 2008, 35 (02) : 660 - 663
  • [10] Registration-Based Reconstruction of Four-Dimensional Cone Beam Computed Tomography
    Christoffersen, Christian P. V.
    Hansen, David
    Poulsen, Per
    Sorensen, Thomas Sangild
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2013, 32 (11) : 2064 - 2077