Characterization of commercial aerogel-enhanced blankets obtained with supercritical drying and of a new ambient pressure drying blanket

被引:44
作者
Berardi, Umberto [1 ]
Zaidi, Syed [1 ]
机构
[1] Ryerson Univ, 350 Victoria St, Toronto, ON M5B 2K3, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Super-insulating materials; Silica aerogel; Aerogel-enhanced blanket; Ambient pressure drying; Material characterization; Effective thermal conductivity; SILICA AEROGEL; THERMAL-CONDUCTIVITY; MECHANICAL-PROPERTIES; INSULATING MATERIALS; PERFORMANCE EVALUATION; BUILDING ENVELOPE; GLASS; SUPERINSULATION; COMPOSITES; RESISTANCE;
D O I
10.1016/j.enbuild.2019.06.027
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Aerogel-enhanced products are often seen as promising materials for providing significant thermal resistance with reduced thickness. In particular, aerogel-enhanced blankets have already shown their effectiveness in several building retrofitting projects. In aerogel-enhanced blankets, a fiber matrix supports the aerogel structure, compensating for the poor mechanical properties of the aerogels. While an increasing body of literature has presented the characterization of specific aerogel-enhanced blankets, no study has so far compared the several commercially-available products. This paper reports the characterization of common aerogel-enhanced blankets produced with supercritical drying (SCD) and of one product produced with ambient pressure drying (APD) by the authors. The different aerogel-enhanced blankets are compared for their bulk density, BET surface area, hydrophilic behavior, chemical composition, and thermal conductivity. IR spectroscopy and contact angle analysis provide insight regarding the hydrophobicity of each blanket. SEM and BET surface area analyses allow to identify structural differences in the blanket filaments and in the binding mechanism of the aerogel to these filaments. The findings provide valuable insight into the differences among products. For example, the thermal conductivity tests confirm the superior performance of aerogel-enhanced blankets compared to traditional insulating materials, but they reveal the temperature dependency of their thermal conductivity and some differences among manufacturer-declared and experimentally-obtained values. The literature review and the experimental comparison between the SCD and APD blankets reveals that only some products are able to achieve extremely low thermal conductivities using APD, with a value around 0.016W/mK, while blankets using an SCD process show thermal conductivity values lower than 0.02 W/mK more consistently. Crown Copyright (C) 2019 Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:542 / 552
页数:11
相关论文
共 71 条
  • [1] Aegerter M. A., 2011, AEROGELS HDB, DOI DOI 10.1007/978-1-4419-7589-8_4
  • [2] AEROCOINS, 2019, AER BAS COMP HYBR NA
  • [3] [Anonymous], 2015, 518 ASTM
  • [4] [Anonymous], 1991, ISO 8301:1991
  • [5] [Anonymous], 2011, AEROGELS HANDB, DOI DOI 10.1007/978-1-4419-7589-8_3
  • [6] [Anonymous], 2013, 828 EN
  • [7] High surface area methyltriethoxysilane-derived aerogels by ambient pressure drying
    Aravind, P. R.
    Soraru, G. D.
    [J]. JOURNAL OF POROUS MATERIALS, 2011, 18 (02) : 159 - 165
  • [8] Aerogel insulation for building applications: A state-of-the-art review
    Baetens, Ruben
    Jelle, Bjorn Petter
    Gustavsen, Arild
    [J]. ENERGY AND BUILDINGS, 2011, 43 (04) : 761 - 769
  • [9] A comparison of the thermal resistance of a foam neoprene wetsuit to a wetsuit fabricated from aerogel-syntactic foam hybrid insulation
    Bardy, Erik
    Mollendorf, Joseph
    Pendergast, David
    [J]. JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2006, 39 (18) : 4068 - 4076
  • [10] Berardi U., 2019, Nanotechnology in Eco-efficient Construction, P395, DOI [10.1016/B978-0-08, DOI 10.1016/B978-0-08-102641-0.00017-7]