Autoclaved aerated concrete (AAC) is a commonly used building material which is favoredby many designers due to its good thermal properties, low bulk density, and easy and fast building. However, failures in the AAC constructionsin a form of cracking of interior or exterior surfaces were observed in the past which could possibly lead to serious consequences for practical applications of AAC. In this paper, moisture-induced length change of AAC is investigated as a very important parameter for designers. According to the producers' data sheets, the shrinkage of AAC is 0.5 mm/m betweenthe volumetric moisture contents of 40% and 5%. It agrees well with the results obtained in this paper. However, the highestlength changes are found between 5% andthe dry material. This property of AAC which is not considered by designers because of unavailability of necessary data may be responsible forsurface cracking in some cases.
引用
收藏
页码:72 / 76
页数:5
相关论文
共 50 条
  • [21] Acoustical properties of aerated autoclaved concrete
    Laukaitis, A
    Fiks, B
    APPLIED ACOUSTICS, 2006, 67 (03) : 284 - 296
  • [22] New opportunities for autoclaved aerated concrete
    Van Boggelen, Willem
    Völker, Kai
    Betonwerk und Fertigteil-Technik/Concrete Precasting Plant and Technology, 2004, 70 (03): : 60 - 64
  • [23] Carbonation degree of autoclaved aerated concrete
    Matsushita, F
    Aono, Y
    Shibata, S
    CEMENT AND CONCRETE RESEARCH, 2000, 30 (11) : 1741 - 1745
  • [24] Reinforced Autoclaved Aerated Concrete in the UK
    Atkins, Chris
    Corrosion Management, 2024, (177): : 30 - 33
  • [25] Water Thermoporometry of Aerated Autoclaved Concrete
    Trnik, Anton
    Koci, Jan
    Madera, Jiri
    INTERNATIONAL CONFERENCE OF NUMERICAL ANALYSIS AND APPLIED MATHEMATICS (ICNAAM 2017), 2018, 1978
  • [26] Autoclaved aerated concrete as an obstacle for burglars
    Flassenberg, Georg
    Jürgen, M.A.
    Küenzlen, H.R.
    Betonwerk und Fertigteil-Technik/Concrete Plant and Precast Technology, 2011, 77 (04): : 16 - 20
  • [27] ANOMALOUS TOBERMORITE IN AUTOCLAVED AERATED CONCRETE
    MITSUDA, T
    CHAN, CF
    CEMENT AND CONCRETE RESEARCH, 1977, 7 (02) : 191 - 194
  • [28] Impact of External Heat Insulation on Drying Process of Autoclaved Aerated Concrete Masonry Constructions
    Rubene, S.
    Vilnitis, M.
    Noviks, J.
    2ND INTERNATIONAL CONFERENCE ON INNOVATIVE MATERIALS, STRUCTURES AND TECHNOLOGIES, 2015, 96
  • [29] Microstructure and Shrinkage Behavior of Autoclaved Aerated Concrete (AAC) -Comparison of Vietnamese and Japanese AACs-
    Nguyen Trong Lam
    Asamoto, Shingo
    Matsui, Kunio
    JOURNAL OF ADVANCED CONCRETE TECHNOLOGY, 2018, 16 (08) : 333 - 342
  • [30] A study of dynamic behavior of the autoclaved aerated concrete
    Belouettar, R.
    Klepaczko, J. R.
    DYMAT 2009: 9TH INTERNATIONAL CONFERENCE ON THE MECHANICAL AND PHYSICAL BEHAVIOUR OF MATERIALS UNDER DYNAMIC LOADING, VOL 1, 2009, : 503 - 509