pnCCD for photon detection from near-infrared to X-rays

被引:26
作者
Meidinger, Norbert
Andritschke, Robert
Hartmann, Robert
Herrmann, Sven
Holl, Peter
Lutz, Gerhard
Strueder, Lothar
机构
[1] Max Planck Inst Extraterr Phys, D-85748 Garching, Germany
[2] PNSensor GmbH, D-80803 Munich, Germany
[3] Max Planck Inst Phys & Astrophys, D-80805 Munich, Germany
[4] MPI Halbleiterlabor, D-81739 Munich, Germany
关键词
avalanche amplifier; photon detection; pnCCD; ROSITA; spectroscopy; XMM-Newton; X-ray CCD;
D O I
10.1016/j.nima.2006.05.006
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A pnCCD is a special type of charge-coupled device developed for spectroscopy and imaging of X-rays with high time resolution and quantum efficiency. Its most famous application is the operation on the XMM-Newton satellite, an X-ray astronomy mission that was launched by the European space agency in 1999. The excellent performance of the focal plane camera has been maintained for more than 6 years in orbit. The energy resolution in particular has shown hardly any degradation since launch. In order to satisfy the requirements of future X-ray astronomy missions as well as those of ground-based experiments, a new type of pnCCD has been developed. This 'frame-store pnCCD' shows an enhanced performance compared to the XMM-Newton type of pnCCD. Now, more options in device design and operation are available to tailor the detector to its respective application. Part of this concept is a programmable analog signal processor, which has been developed for the readout of the CCD signals. The electronic noise of the new detector has a value of only 2 electrons equivalent noise charge (ENC), which is less than half of the figure achieved for the XMM-Newton-type pnCCD. The energy resolution for the Mn-K-alpha line at 5.9 keV is approximately 130 eV FWHM. We have close to 100% quantum efficiency for both low- and high-energy photon detection (e.g. the GK line at 277eV, and the Ge-K-alpha line at l0keV, respectively). Very high frame rates of 1000 images/s have been achieved due to the ultra-fast readout accomplished by the parallel architecture of the pnCCD and the analog signal processor. Excellent spectroscopic performance is shown even at the relatively high operating temperature of -25 degrees C that can be achieved by a Peltier cooler. The applications of the low-noise and fast pnCCD detector are not limited to the detection of X-rays. With an anti-reflective coating deposited on the photon entrance window, we achieve high quantum efficiency also for near-infrared and optical photons. A novel type of pnCCD is in preparation, which allows single optical photon counting. This feature is accomplished by implementation of an avalanche-type amplifier in the pnCCD concept. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:251 / 257
页数:7
相关论文
共 12 条
[1]   Novel digital K-edge imaging system with transition radiation from an 855-MeV electron beam [J].
Hagenbuck, F ;
Backe, H ;
Clawiter, N ;
Euteneuer, H ;
Görgen, F ;
Holl, P ;
Johann, K ;
Kaiser, KH ;
Kemmer, J ;
Kerschner, T ;
Kettig, O ;
Koch, H ;
Kube, G ;
Lauth, W ;
Matthäy, H ;
Schütrumpf, M ;
Stötter, R ;
Strüder, L ;
Walcher, T ;
Wilms, A ;
von Zanthier, C ;
Zemter, M .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2001, 48 (03) :843-848
[2]   A high-speed frame store CCD for the use in optical and near infrared astronomy [J].
Hartmann, R ;
Holl, P ;
Strüder, L ;
Von Zanthier, C .
ADAPTIVE OPTICAL SYSTEMS TECHNOLOGY, PTS 1 AND 2, 2000, 4007 :493-499
[3]  
HARTMANN R, 2005, 10 EUR S SEM DET WIL
[4]   Electron emission channeling spectroscopy using X-ray CCD detectors [J].
Hofsäss, H ;
Vetter, U ;
Ronning, C ;
Uhrmacher, M ;
Bharuth-Ram, K ;
Hartmann, R ;
Strüder, L .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 512 (1-2) :378-385
[5]   High-order harmonic generation at a repetition rate of 100 kHz -: art. no. 013814 [J].
Lindner, F ;
Stremme, W ;
Schätzel, MG ;
Grasbon, F ;
Paulus, GG ;
Walther, H ;
Hartmann, R ;
Strüder, L .
PHYSICAL REVIEW A, 2003, 68 (01) :8
[6]   The avalanche drift diode:: A new detector concept for single photon detection [J].
Lutz, G ;
Otte, N ;
Richter, RH ;
Strüder, L .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2005, 52 (04) :1156-1159
[7]   An application of space technology to the terrestrial search for axions:: the X-ray mirror telescope at CAST [J].
Lutz, G ;
Bräuninger, H ;
Englhauser, J ;
Hartmann, R ;
Kang, D ;
Kotthaus, R ;
Kuster, M ;
Serber, W ;
Strüder, L .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 518 (1-2) :201-206
[8]   CCD detector development for the DUO and the ROSITA mission [J].
Meidinger, N ;
Bonerz, S ;
Englhauser, J ;
Hasinger, G ;
Hartmann, R ;
Herrmann, S ;
Holl, P ;
Kettenring, G ;
Kimmel, N ;
Lutz, G ;
Pfeffermann, E ;
Predehl, P ;
Soltau, H ;
Strüder, L .
HIGH-ENERGY DETECTORS IN ASTRONOMY, 2004, 5501 :66-77
[9]  
MEIDINGER N, 2004, MEM S A IT, V75, P551
[10]   The European Photon Imaging Camera on XMM-Newton:: The pn-CCD camera [J].
Strüder, L ;
Briel, U ;
Dennerl, K ;
Hartmann, R ;
Kendziorra, E ;
Meidinger, N ;
Pfeffermann, E ;
Reppin, C ;
Aschenbach, B ;
Bornemann, W ;
Bräuninger, H ;
Burkert, W ;
Elender, M ;
Freyberg, M ;
Haberl, F ;
Hartner, H ;
Heuschmann, F ;
Hippmann, H ;
Kastelic, E ;
Kemmer, S ;
Kettenring, G ;
Kink, W ;
Krause, N ;
Müller, S ;
Oppitz, A ;
Pietsch, W ;
Popp, M ;
Predehl, P ;
Read, A ;
Stephan, KH ;
Stötter, D ;
Trümper, J ;
Holl, P ;
Kemmer, J ;
Soltau, H ;
Stötter, R ;
Weber, U ;
Weichert, U ;
von Zanthier, C ;
Carathanassis, D ;
Lutz, G ;
Richter, RH ;
Solc, P ;
Böttcher, H ;
Kuster, M ;
Staubert, R ;
Abbey, A ;
Holland, A ;
Turner, M ;
Balasini, M .
ASTRONOMY & ASTROPHYSICS, 2001, 365 (01) :L18-L26