Kinematics of the midcarpal and radiocarpal joint in flexion and extension:: An in vitro study

被引:38
作者
Kaufmann, Robert A.
Pfaeffle, H. James
Blankenhorn, Brad D.
Stabile, Kathryne
Robertson, Doug
Goitz, Robert
机构
[1] Univ Pittsburgh, Dept Orthopaed Surg, Musculoskeletal Imaging & Biomech Lab, Pittsburgh, PA 15213 USA
[2] Univ Pittsburgh, Dept Radiol, Pittsburgh, PA 15213 USA
[3] Univ Pittsburgh, Dept Bioengn, Pittsburgh, PA 15213 USA
来源
JOURNAL OF HAND SURGERY-AMERICAN VOLUME | 2006年 / 31A卷 / 07期
关键词
kinematics; wrist; noninvasive;
D O I
10.1016/j.jhsa.2006.05.002
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: To apply carpal kinematic analysis using noninvasive medical imaging to investigate the midcarpal and radiocarpal contributions to wrist flexion and extension in a quasi-dynamic in vitro model. Methods: Eight fresh-frozen cadaver wrists were scanned with computed tomography in neutral, full flexion, and full extension. Body-mass-based local coordinate systems were used to track motion of the capitate, lunate, and scaphoid with the radius as a fixed reference. Helical axis motion parameters and Euler angles were calculated for flexion and extension. Results: Minimal out-of-plane carpal motion was noted with the exception of small amounts of ulnar deviation and supination in flexion. Overall wrist flexion was 68 degrees +/- 12 degrees and extension was 50 degrees+/- 12 degrees. In flexion, 75% of wrist motion occurred at the radioscaphoid joint, and 50% occurred at the radiolunate joint. In extension, 92% of wrist motion occurred at the radioscaphoid joint, and 52% occurred at the radiolunate, joint. Midcarpal flexion/extension between the capitate and scaphoid was 0 degrees +/- 5 degrees in extension and 10 degrees +/- 13 degrees in flexion. Midcarpal flexion/extension between the capitate and lunate was larger, with 15 degrees +/- 11 degrees in extension and 22 degrees +/- 19 degrees in flexion. Conclusions: The capitate and scaphoid tend to move together. This results in greater flexion/extension for the scaphoid than the lunate at the radiocarpal joint. The lunate has greater midcarpal motion between it and the capitate than the scaphoid does with the capitate. The engagement between the scaphoid and capitate is particularly evident during wrist extension. Out-of-plane motion was primarily ulnar deviation at the radiocarpal joint during flexion. These results are clinically useful in understanding the consequences of isolated fusions in the treatment of wrist instability.
引用
收藏
页码:1142 / 1148
页数:7
相关论文
共 27 条
[1]   Advances in the in vivo measurement of normal and abnormal carpal kinematics [J].
Crisco, JJ ;
Wolfe, SW ;
Neu, CP ;
Pike, S .
ORTHOPEDIC CLINICS OF NORTH AMERICA, 2001, 32 (02) :219-231
[2]  
Crisco TJ, 1999, J ORTHOP RES, V17, P96
[3]   A method for measuring joint kinematics designed for accurate registration of kinematic data to models constructed from CT data [J].
Fischer, KJ ;
Manson, TT ;
Pfaeffle, HJ ;
Tomaino, MM ;
Woo, SLY .
JOURNAL OF BIOMECHANICS, 2001, 34 (03) :377-383
[4]   A KINEMATIC STUDY OF LUNO-TRIQUETRAL DISSOCIATIONS [J].
HORII, E ;
GARCIAELIAS, M ;
AN, KN ;
BISHOP, AT ;
COONEY, WP ;
LINSCHEID, RL ;
CHAO, EYS .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1991, 16A (02) :355-362
[5]  
Ishikawa J, 1999, J HAND SURG-AM, V24A, P113
[6]   THE EFFECTS OF INSITU FREEZING ON THE ANTERIOR CRUCIATE LIGAMENT - AN EXPERIMENTAL-STUDY IN GOATS [J].
JACKSON, DW ;
GROOD, ES ;
COHN, BT ;
ARNOCZKY, SP ;
SIMON, TM ;
CUMMINGS, JF .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1991, 73A (02) :201-213
[7]   Kinematics of the midcarpal and radiocarpal joints in radioulnar deviation:: An in vitro study [J].
Kaufmann, R ;
Pfaeffle, J ;
Blankenhorn, B ;
Stabile, K ;
Robertson, D ;
Goitz, R .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2005, 30A (05) :937-942
[8]  
Kobayashi M, 1997, HAND CLIN, V13, P143
[9]  
MACCONAILL MA, 1941, J NAT, V74, P166
[10]   INTRAOPERATIVE ASSESSMENT OF WRIST EXTENSOR MUSCLE FORCE [J].
MENDELSON, LS ;
PECKHAM, PH ;
FREEHAFER, AA ;
KEITH, MW .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1988, 13A (06) :832-836