Static and Dynamic Characteristics of a Long-Span Cable-Stayed Bridge with CFRP Cables

被引:46
作者
Xie, Xu [1 ]
Li, Xiaozhang [1 ]
Shen, Yonggang [1 ]
机构
[1] Zhejiang Univ, Dept Civil Engn, Hangzhou 310058, Zhejiang, Peoples R China
基金
中国国家自然科学基金;
关键词
CFRP stay cables; long span; cable-stayed bridge; static characteristics; dynamic characteristics; NONLINEAR VIBRATIONS; 3; DIMENSIONS;
D O I
10.3390/ma7064854
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
In this study, the scope of CFRP cables in cable-stayed bridges is studied by establishing a numerical model of a 1400-m span of the same. The mechanical properties and characteristics of CFRP stay cables and of a cable-stayed bridge with CFRP cables are here subjected to comprehensive analysis. The anomalies in the damping properties of free vibration, nonlinear parametric vibration and wind fluctuating vibration between steel cables and CFRP cables are determined. The structural stiffness, wind resistance and traffic vibration of the cable-stayed bridge with CFRP cables are also analyzed. It was found that the static performances of a cable-stayed bridge with CFRP cables and steel cables are basically the same. The natural frequencies of CFRP cables do not coincide with the major natural frequencies of the cable-stayed bridge, so the likelihood of CFRP cable-bridge coupling vibration is minuscule. For CFRP cables, the response amplitudes of both parametric vibration and wind fluctuating vibration are smaller than those of steel cables. It can be concluded from the research that the use of CFRP cables does not change the dynamic characteristics of the vehicle-bridge coupling vibration. Therefore, they can be used in long-span cable-stayed bridges with an excellent mechanical performance.
引用
收藏
页码:4854 / 4877
页数:24
相关论文
共 50 条
  • [31] Dynamic analysis and modal test of long-span cable-stayed bridge based on ambient excitation
    陈常松
    颜东煌
    Journal of Central South University of Technology, 2007, (01) : 135 - 139
  • [33] Static Performance of a Long-Span Concrete Cable-Stayed Bridge Subjected to Multiple-Cable Loss during Construction
    Zhang, Yu
    Fang, Zhi
    Jiang, Ruinian
    Xiang, Yu
    Long, Haibin
    Lu, Jiangbo
    JOURNAL OF BRIDGE ENGINEERING, 2020, 25 (03)
  • [34] Fatigue Damage Factor Calibration for Long-Span Cable-Stayed Bridge Decks
    Nussbaumer, A.
    Pedro, J. Oliveira
    Baptista, C. A. Pereira
    Duval, M.
    MECHANICAL FATIGUE OF METALS: EXPERIMENTAL AND SIMULATION PERSPECTIVES, 2019, 7 : 369 - 376
  • [35] Seismic Design of a Long-Span Cable-Stayed Bridge with Fluid Viscous Dampers
    Zhu, Jin
    Zhang, Wei
    Zheng, K. F.
    Li, H. G.
    PRACTICE PERIODICAL ON STRUCTURAL DESIGN AND CONSTRUCTION, 2016, 21 (01)
  • [36] The Design and Study on Long-Span Road-Rail Cable-Stayed Bridge
    Zhang, Xianqing
    Guo, Shulun
    Lei, Junqing
    6TH INTERNATIONAL CONFERENCE ON ENVIRONMENTAL SCIENCE AND CIVIL ENGINEERING, 2020, 455
  • [37] RESEARCH ON THE ASEISMIC BEHAVIOR OF LONG-SPAN CABLE-STAYED BRIDGE WITH DAMPING EFFECT
    Wu Fangwen
    Zhang Qingkai
    Feng Binglong
    Qiu Jiantao
    CIVIL ENGINEERING JOURNAL-STAVEBNI OBZOR, 2016, 25 (02):
  • [38] HEALTH MONITORING SYSTEM OF LONG-SPAN PRESTRESSED CONCRETE CABLE-STAYED BRIDGE
    Tu, Guangya
    Yan, Donghuang
    Chen, Changsong
    INTERNATIONAL SYMPOSIUM ON LIFE-CYCLE PERFORMANCE OF BRIDGES AND STRUCTURES, 2010, : 196 - 200
  • [39] Nonlinear Analysis of Spatial Cable of Long-Span Cable-Stayed Bridge considering Rigid Connection
    Zhiqiang Wu
    Jun Wei
    KSCE Journal of Civil Engineering, 2019, 23 : 2148 - 2157
  • [40] Evaluation of Thermal Effects on Cable Forces of a Long-Span Prestressed Concrete Cable-Stayed Bridge
    Wang, J. F.
    Zhang, J. T.
    Xu, R. Q.
    Yang, Z. X.
    JOURNAL OF PERFORMANCE OF CONSTRUCTED FACILITIES, 2019, 33 (06)