Meta-Analysis of Diagnostic Efficacy of 64-Slice Computed Tomography in the Evaluation of Coronary In-Stent Restenosis

被引:61
|
作者
Kumbhani, Dharam J. [1 ]
Ingelmo, Christopher P. [1 ]
Schoenhagen, Paul [1 ,2 ]
Curtin, Ronan J. [1 ,2 ]
Flamm, Scott D. [1 ,2 ]
Desai, Milind Y. [1 ,2 ]
机构
[1] Cleveland Clin, Inst Heart & Vasc, Cleveland, OH 44106 USA
[2] Cleveland Clin, Imaging Inst, Cleveland, OH 44106 USA
关键词
BARE-METAL STENTS; ELUTING STENTS; CT ANGIOGRAPHY; PATENCY; ACCURACY; PERFORMANCE; CARDIOLOGY; ARTERIES;
D O I
10.1016/j.amjcard.2009.02.024
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We sought to conduct a meta-analysis using available studies to determine the diagnostic efficacy of 64-slice computed tomography (CT) in evaluation of in-stent restenosis (ISR). Sixty-four-slice CT allows optimal noninvasive assessment of coronary artery disease. However, a variety of artifacts limit evaluation of stented coronary segments. We included studies that used 64-slice CT for evaluation of coronary ISR. We pooled efficacy estimates across studies using random-effects models. We identified 14 studies, which included 895 patients (1,447 stents, mean diameter 3.1 mm). Of these, 1,231 (91.4%) stents were adequately assessed by 64-slice CT. Overall sensitivity was 91% (95% confidence interval [CI] 86 to 94), specificity was 91% (95% CI 89 to 92), positive predictive value (PPV) was 68% (95% CI 63 to 73), and negative predictive value (NPV) was 98% (95% CI 97 to 99). The summary receiver operating characteristic curves graph showed a symmetric area under the curve of 0.96. When nonassessable segments were included, overall sensitivity and specificity decreased to 87% (95% CI 81 to 92) and 84% (95% CI 82 to 87), with a PPV of 53% (95% CI 47 to 59) and an NPV of 97% (95% CI 96 to 98), respectively. In conclusion, 64-slice CT detects (high sensitivity and specificity) or excludes ISR (high NPV) with a high degree of confidence; however, precise quantification of ISR is not accurate (low PPV). Efficacy estimates are even lower when nonassessable segments are included. Hence, at this point, stress imaging remains the most acceptable noninvasive technique for diagnosis of ISR. (C) 2009 Elsevier Inc. All rights reserved. (Am J Cardiol 2009;103:1675-1681)
引用
收藏
页码:1675 / 1681
页数:7
相关论文
共 50 条
  • [41] Spectral Photon-Counting Computed Tomography for Coronary Stent Imaging Evaluation of the Potential Clinical Impact for the Delineation of In-Stent Restenosis
    Bratke, Grischa
    Hickethier, Tilman
    Bar-Ness, Daniel
    Bunck, Alexander Christian
    Maintz, David
    Pahn, Gregor
    Coulon, Philippe
    Si-Mohamed, Salim
    Douek, Philippe
    Sigovan, Monica
    INVESTIGATIVE RADIOLOGY, 2020, 55 (02) : 61 - 67
  • [42] Comparative Efficacy and Safety of Drug-Eluting Stent and Conventional Therapies in Coronary Heart Disease Patients with In-Stent Restenosis: A Meta-Analysis
    Sun, Yuhan
    Li, Lang
    Su, Qiang
    Lu, Yongguang
    CELL BIOCHEMISTRY AND BIOPHYSICS, 2014, 68 (01) : 211 - 229
  • [43] Comparison of the diagnostic performance of 64-slice computed tomography coronary angiography in diabetic and non-diabetic patients with suspected coronary artery disease
    Andreini, Daniele
    Pontone, Gianluca
    Bartorelli, Antonio L.
    Agostoni, Piergiuseppe
    Mushtaq, Saima
    Antonioli, Laura
    Cortinovis, Sarah
    Canestrari, Mauro
    Annoni, Andrea
    Ballerini, Giovanni
    Fiorentini, Cesare
    Pepi, Mauro
    CARDIOVASCULAR DIABETOLOGY, 2010, 9
  • [44] Diagnostic accuracy of 320-slice computed tomography angiography for detection of coronary artery stenosis: Meta-analysis
    Li, Suhua
    Ni, Qiongqiong
    Wu, Huilan
    Peng, Long
    Dong, Ruimin
    Chen, Lin
    Liu, Jinlai
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2013, 168 (03) : 2699 - 2705
  • [45] Angiographic patterns of in-stent restenosis classified by computed tomography in patients with drug-eluting stents: correlation with invasive coronary angiography
    Pan, Jingwei
    Lu, Zhigang
    Zhang, Jiayin
    Li, Minghua
    Wei, Meng
    EUROPEAN RADIOLOGY, 2013, 23 (01) : 101 - 107
  • [46] Management of Drug Eluting Stent in-Stent Restenosis: A Systematic Review and Meta-Analysis
    Goel, Sachin S.
    Gajulapalli, Rama Dilip
    Athappan, Ganesh
    Philip, Femi
    Gupta, Supriya
    Tuzcu, E. Murat
    Ellis, Stephen G.
    Mishkel, Gregory
    Kapadia, Samir R.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2016, 87 (06) : 1080 - 1091
  • [47] Combined diagnostic performance of coronary computed tomography angiography and computed tomography derived fractional flow reserve for the evaluation of myocardial ischemia: A meta-analysis
    Tan, Xiao Wei
    Zheng, Qishi
    Shi, Luming
    Gao, Fei
    Allen, John Carson
    Coenen, Adriaan
    Baumann, Stefan
    Schoepf, U. Joseph
    Kassab, Ghassan S.
    Lima, Soo Teik
    Wong, Aaron Sung Lung
    Tan, Jack Wei Chieh
    Yeo, Khung Keong
    Chin, Chee Tang
    Ho, Kay Woon
    Tan, Swee Yaw
    Chua, Terrance Siang Jin
    Chan, Edwin Shih Yen
    Tan, Ru San
    Zhong, Liang
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2017, 236 : 100 - 106
  • [48] Visualization of anomalous origin and course of coronary arteries in 748 consecutive symptomatic patients by 64-slice computed tomography angiography
    von Ziegler, Franz
    Pilla, Marco
    McMullan, Lori
    Panse, Prasad
    Leber, Alexander W.
    Wilke, Norbert
    Becker, Alexander
    BMC CARDIOVASCULAR DISORDERS, 2009, 9
  • [49] Quantification and Characterization of Obstructive Coronary Plaques Using 64-Slice Computed Tomography: A Comparison With Intravascular Ultrasound
    Hur, Jin
    Kim, Young Jin
    Lee, Hye-Jeong
    Nam, Ji Eun
    Choe, Kyu Ok
    Seo, Jae Seung
    Choi, Dong-Hoon
    Kim, Jung-Sun
    Choi, Byoung Wook
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2009, 33 (02) : 186 - 192
  • [50] Interobserver variability of 64-slice computed tomography for the quantification of non-calcified coronary atherosclerotic plaque
    Plflederer, T.
    Schmid, M.
    Ropers, D.
    Rapers, U.
    Komatsu, S.
    Daniel, W. G.
    Achenbach, S.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2007, 179 (09): : 953 - 957