Meta-Analysis of Diagnostic Efficacy of 64-Slice Computed Tomography in the Evaluation of Coronary In-Stent Restenosis

被引:61
|
作者
Kumbhani, Dharam J. [1 ]
Ingelmo, Christopher P. [1 ]
Schoenhagen, Paul [1 ,2 ]
Curtin, Ronan J. [1 ,2 ]
Flamm, Scott D. [1 ,2 ]
Desai, Milind Y. [1 ,2 ]
机构
[1] Cleveland Clin, Inst Heart & Vasc, Cleveland, OH 44106 USA
[2] Cleveland Clin, Imaging Inst, Cleveland, OH 44106 USA
关键词
BARE-METAL STENTS; ELUTING STENTS; CT ANGIOGRAPHY; PATENCY; ACCURACY; PERFORMANCE; CARDIOLOGY; ARTERIES;
D O I
10.1016/j.amjcard.2009.02.024
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We sought to conduct a meta-analysis using available studies to determine the diagnostic efficacy of 64-slice computed tomography (CT) in evaluation of in-stent restenosis (ISR). Sixty-four-slice CT allows optimal noninvasive assessment of coronary artery disease. However, a variety of artifacts limit evaluation of stented coronary segments. We included studies that used 64-slice CT for evaluation of coronary ISR. We pooled efficacy estimates across studies using random-effects models. We identified 14 studies, which included 895 patients (1,447 stents, mean diameter 3.1 mm). Of these, 1,231 (91.4%) stents were adequately assessed by 64-slice CT. Overall sensitivity was 91% (95% confidence interval [CI] 86 to 94), specificity was 91% (95% CI 89 to 92), positive predictive value (PPV) was 68% (95% CI 63 to 73), and negative predictive value (NPV) was 98% (95% CI 97 to 99). The summary receiver operating characteristic curves graph showed a symmetric area under the curve of 0.96. When nonassessable segments were included, overall sensitivity and specificity decreased to 87% (95% CI 81 to 92) and 84% (95% CI 82 to 87), with a PPV of 53% (95% CI 47 to 59) and an NPV of 97% (95% CI 96 to 98), respectively. In conclusion, 64-slice CT detects (high sensitivity and specificity) or excludes ISR (high NPV) with a high degree of confidence; however, precise quantification of ISR is not accurate (low PPV). Efficacy estimates are even lower when nonassessable segments are included. Hence, at this point, stress imaging remains the most acceptable noninvasive technique for diagnosis of ISR. (C) 2009 Elsevier Inc. All rights reserved. (Am J Cardiol 2009;103:1675-1681)
引用
收藏
页码:1675 / 1681
页数:7
相关论文
共 50 条
  • [1] Diagnostic accuracy of 64-slice computed tomography coronary angiography for the detection of in-stent restenosis: A meta-analysis
    Carrabba, Nazario
    Schuijf, Joanne D.
    de Graaf, Fleur R.
    Parodi, Guido
    Maffei, Erica
    Valenti, Renato
    Palumbo, Alessandro
    Weustink, Annick C.
    Mollet, Nico R.
    Accetta, Gabriele
    Cademartiri, Filippo
    Antoniucci, David
    Bax, Jeroen J.
    JOURNAL OF NUCLEAR CARDIOLOGY, 2010, 17 (03) : 470 - 478
  • [2] Evaluation of coronary artery in-stent patency using 64-slice computed tomography
    Zhao, Jing
    Zheng, Li-li
    Yang, Youyou
    CORONARY ARTERY DISEASE, 2011, 22 (08) : 540 - 552
  • [3] High diagnostic accuracy of prospective ECG-gating 64-slice computed tomography coronary angiography for the detection of in-stent restenosis
    Andreini, Daniele
    Pontone, Gianluca
    Bartorelli, Antonio L.
    Mushtaq, Saima
    Trabattoni, Daniela
    Bertella, Erika
    Cortinovis, Sarah
    Annoni, Andrea
    Formenti, Alberto
    Ballerini, Giovanni
    Agostoni, Piergiuseppe
    Fiorentini, Cesare
    Pepi, Mauro
    EUROPEAN RADIOLOGY, 2011, 21 (07) : 1430 - 1438
  • [4] Diagnostic accuracy of 64 multislice CT angiography in the assessment of coronary in-stent restenosis: A meta-analysis
    Sun, Zhonghua
    Almutairi, Abdulrahman Marzouq D.
    EUROPEAN JOURNAL OF RADIOLOGY, 2010, 73 (02) : 266 - 273
  • [5] Diagnostic performance of computed tomography angiography in the detection of coronary artery in-stent restenosis: evidence from an updated meta-analysis
    Dai, Tao
    Wang, Jiang-rong
    Hu, Peng-fei
    EUROPEAN RADIOLOGY, 2018, 28 (04) : 1373 - 1382
  • [6] Evaluation of coronary in-stent restenosis by 64-slice computed tomography in patients with optimal heart rate control by systematic administration of beta-blocker drugs
    Martuscelli, Eugenio
    Romagnoli, Andrea
    D'Eliseo, Alessia
    Sperandio, Massimiliano
    Di Luozzo, Marco
    De Angelis, Barbara
    Romeo, Francesco
    Simonetti, Giovanni
    JOURNAL OF CARDIOVASCULAR MEDICINE, 2010, 11 (06) : 431 - 439
  • [7] Comparative analysis between 64-and 320-slice spiral computed tomography in the display of coronary artery stents and diagnosis of in-stent restenosis
    Yue, Junyan
    Chen, Jie
    Dou, Wenguang
    Hu, Ying
    Li, Qiang
    Zhou, Fengmei
    Cui, Hongkai
    Wu, Qingwu
    Yang, Ruimin
    EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2015, 10 (05) : 1871 - 1876
  • [8] Diagnostic value of cardiac 64-slice computed tomography: Importance of coronary calcium
    Diederichsen, Axel C. P.
    Petersen, Henrik
    Jensen, Lisette O.
    Thayssen, Per
    Gerke, Oke
    Sandgaard, Niels C. F.
    Hoilund-Carlsen, Poul F.
    Mickley, Hans
    SCANDINAVIAN CARDIOVASCULAR JOURNAL, 2009, 43 (05) : 337 - 344
  • [9] Diagnostic accuracy of dual-source computed tomography angiography for the detection of coronary in-stent restenosis: A systematic review and meta-analysis
    Liu, Wen-Jun
    Li, Gui-Zhen
    Liu, Hai-Feng
    Lei, Jun-Qiang
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2018, 35 (04): : 541 - 550
  • [10] Comparison of Feasibility and Diagnostic Accuracy of 64-Slice Multidetector Computed Tomographic Coronary Angioraphy Versus Invasive Coronary Angiography Versus Intravascular Ultrasound for Evaluation of In-Stent Restenosis
    Andreini, Daniele
    Pontone, Gianluca
    Bartorelli, Antonio L.
    Trabattoni, Daniela
    Mushtaq, Saima
    Bertella, Erika
    Annoni, Andrea
    Formenti, Alberto
    Cortinovis, Sarah
    Montorsi, Piero
    Veglia, Fabrizio
    Ballerini, Giovanni
    Pepi, Mauro
    AMERICAN JOURNAL OF CARDIOLOGY, 2009, 103 (10) : 1349 - 1358