Effect of Fibrous Jacket on Behavior of RC Columns

被引:4
作者
Mhuder, Wathiq Jassim [1 ]
Chassib, Samir M. [1 ]
机构
[1] Misan Univ, Civil Engn Dept, Coll Engn, Maysan 62001, Iraq
来源
CIVIL ENGINEERING JOURNAL-TEHRAN | 2020年 / 6卷 / 10期
关键词
Square Columns; Concrete Jackets; Steel Fibers; Jacket Thickness; Ductility; Finite Element; REINFORCED-CONCRETE COLUMNS; COMPRESSIVE BEHAVIOR; FLEXURAL BEHAVIOR; SEISMIC RETROFIT; STEEL; POLYPROPYLENE; PERFORMANCE; STRENGTH; FIBERS; DESIGN;
D O I
10.28991/cej-2020-03091589
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper presented an extensive study about the strengthening of RC square short columns with high strength concrete jackets reinforced with steel fiber. The aim of this study is to investigate the effect of confinement by fibrous jacket on the behavior of RC column. A comparative study is performed on 23 square columns (six of them were unconfined columns where the remaining seventeen were confined columns) with varied parameters such as steel fibers ratio and type, jacket thickness, partial and full strengthening, type of confining jacket (hoop and composite), use of epoxy as bond material between the concrete column and strengthening jacket, and length parameter. The test results showed that the strengthened columns showed a significant improvement in the ultimate stress, load-carrying capacity, maximum strain, ductility, and energy absorption. Increase the steel fibers ratio (1, 1.5 and 2%) increased the ultimate stress by (22.5, 12.3 and 12.5%) respectively. The use of epoxy as bond material enhanced the ultimate stress by an average improvement by (55%). Composite case in the strengthening enhanced the load-carrying capacity larger than hoop case by (28.7 and 42%) for FRC jackets with hooked and straight fibers respectively but in case of stress capacity, hoop jacket carries stresses more than composite according to the stressed cross-sectional area. Increase jacket thickness (25 and 35 mm) enhanced the ultimate stress by (28.7 and 15.5%) respectively. Partial strengthening has a good enhancement in the ultimate load but was less than full strengthening. Increase the length by (25 cm) decreased the enhancement in load capacity of the column with hoop jacket by (45.3%). Concrete jackets enhanced Energy absorption and ductility which improved the deformation capacity. The compressive behavior of stub concrete columns was also modeled, simulated, and analyzed numerically by a 3D nonlinear finite element model. The verification process was performed against the reported data of the experimental test which proved the results of experimental results and showed a good agreement between experimental and numerical outcomes.
引用
收藏
页码:1876 / 1894
页数:19
相关论文
共 58 条
[1]  
Abdullah, 2003, CEMENT CONCRETE COMP, V25, P233
[2]  
Al-Sibahy A., 2016, WORLD J ENG TECHNOL, V4, P608
[3]  
American Society of Testing and Materials (ASTM), 2005, C191 ASTM, DOI [10.1002/0471740039.vec0155, DOI 10.1002/0471740039.VEC0155]
[4]  
American Society of Testing and Materials (ASTM), 2001, C136 ASTM, DOI [10.1002/ep.670180104, DOI 10.1002/EP.670180104]
[5]  
[Anonymous], 1984, IRAQI STANDARD NO 45
[6]  
[Anonymous], 2017, ASTM C109/C109M-01, DOI [10.1520/C0109_C0109M-01, DOI 10.1520/C0109_C0109M-01]
[7]  
[Anonymous], C494 ASTM, DOI [10.1520/c0494_c0494m-10a, DOI 10.1520/C0494_C0494M-10A]
[8]  
ANSYS, 2009, ANSYS US MAN VERS 12
[9]   Effect of Steel Fiber and Different Environments on Flexural Behavior of Reinforced Concrete Beams [J].
Bafghi, Mohammad Ali Barkhordari ;
Amini, Fereydon ;
Nikoo, Hamed Safaye ;
Sarkardeh, Hamed .
APPLIED SCIENCES-BASEL, 2017, 7 (10)
[10]   Uniaxial tension test for steel fibre reinforced concrete -: a parametric study [J].
Barragán, BE ;
Gettu, R ;
Martín, MA ;
Zerbino, RL .
CEMENT & CONCRETE COMPOSITES, 2003, 25 (07) :767-777