Comparison of the Bishop score, body mass index and transvaginal cervical length in predicting the success of labor induction

被引:37
|
作者
Uyar, Yildiz [1 ]
Erbay, Gurcan [2 ]
Demir, Bilge Cetinkaya [1 ]
Baytur, Yesim [1 ]
机构
[1] Celal Bayar Univ, Fac Med, Dept Obstet & Gynecol, Manisa, Turkey
[2] E Hayri Ustundag Obstet & Gynecol Clin, Izmir, Turkey
关键词
Labor induction; Body mass index; Cervical length; Bishop score; Birth weight; PREINDUCTION SONOGRAPHIC MEASUREMENT; CESAREAN DELIVERY; PROLONGED PREGNANCY; NULLIPAROUS WOMEN; ULTRASOUND; RISK; WEIGHT; COMPLICATIONS; OVERWEIGHT; DURATION;
D O I
10.1007/s00404-008-0915-x
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
To evaluate the role of ultrasonographic and various maternal and fetal parameters in predicting successful labor induction. Body mass index, cervical length, dilatation, effacement, Bishop score, parity, maternal age and birth weight were evaluated in 189 singleton pregnant women at 37-42 weeks of gestation and having induction of labor. All underwent induction of labor with oxytocin. Body mass index was calculated using the formula weight (kg)/height(2) (m), cervical measurement was performed by transvaginal ultrasonography and Bishop score was determined by digital examination of cervix. Logistic regression analysis indicated that the cervical length and body mass index were independent variables in determining the risk of cesarean section (OR = 1.206, P = 0.000, CI 95% = 1.117-1.303; OR = 1.223, P = 0.007, CI 95% = 1.058-1.414 respectively). In multiple linear regression analysis, the effect of cervical length and body mass index on induction delivery interval was found to be statistically significant (t = 5.738, P = 0.000; t = 2.680, P = 0.009, respectively). ROC curve showed that the best parameter in predicting the risk of cesarean section was cervical length and that cervical length and body mass index were better parameters compared to the Bishop score (the areas under the curve are 0.819, 0.701 and 0.416, respectively). Body mass index and transvaginal cervical length were better predictors compared to the Bishop score in determining the success of labor induction.
引用
收藏
页码:357 / 362
页数:6
相关论文
共 50 条
  • [31] Transvaginal ultrasonography-measured cervical length versus the modified Bishop score for preinduction cervical assessment at term: A randomised controlled trial
    Okafor, Chigozie G.
    Eleje, George U.
    Ikechebelu, Joseph I.
    Okafor, Chisolum O.
    Nwosu, Betrand O.
    Okafor, Chidinma C.
    Udigwe, Gerald O.
    Mamah, Johnbosco E.
    Ezema, Evaristus C.
    Ogabido, Chukwudi A.
    Obiagwu, Hillary, I
    Okoro, Chukwuemeka C.
    Njoku, Tobechi K.
    Olisa, Chinedu L.
    Okaforcha, Emmanuel, I
    Okonkwo, Ifeanyi O.
    Okafor, Lazarus U.
    Okoye, Kelechi U.
    Nnabuchi, Obinna K.
    Agbanu, Chiemezie M.
    Eke, Ahizechukwu C.
    ULTRASOUND, 2024,
  • [32] Comparison of the Bishop score, ultrasonographically measured cervical length, and fetal fibronectin assay in predicting time until delivery and type of delivery at term
    Rozenberg, P
    Goffinet, F
    Hessabi, M
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2000, 182 (01) : 108 - 113
  • [33] The impact of preconception body mass index on cervical length: a prospective cohort study in China
    An, Hang
    Nan, Li
    Gao, Suhong
    Li, Zhiwen
    Wang, Jiamei
    Liu, Xiaohong
    Ye, Rongwei
    JOURNAL OF MATERNAL-FETAL & NEONATAL MEDICINE, 2021, 34 (24) : 4077 - 4081
  • [34] Influence of body mass index on induction of labor: A historical cohort study
    Dammer, Ulf
    Bogner, Roswitha
    Weiss, Christel
    Faschingbauer, Florian
    Pretscher, Jutta
    Beckmann, Matthias W.
    Suetterlin, Marc
    Kehl, Sven
    JOURNAL OF OBSTETRICS AND GYNAECOLOGY RESEARCH, 2018, 44 (04) : 697 - 707
  • [35] Fetal fibronectin is more valuable than ultrasonographic examination of the cervix or Bishop score in predicting successful induction of labor
    Uygur, Dilek
    Ozgu-Erdinc, A. Seval
    Deveer, Ruya
    Aytan, Hakan
    Mungan, M. Tamer
    TAIWANESE JOURNAL OF OBSTETRICS & GYNECOLOGY, 2016, 55 (01): : 94 - 97
  • [36] Transvaginal ultrasonographic cervical measurement in predicting failed labor induction and cesarean delivery for failure to progress in nulliparous women
    Park, Kyo Hoon
    JOURNAL OF KOREAN MEDICAL SCIENCE, 2007, 22 (04) : 722 - 727
  • [37] Maternal body mass index and cervical length among women with a history of spontaneous preterm birth†
    Venkatesh, Kartik K.
    Manuck, Tracy A.
    JOURNAL OF MATERNAL-FETAL & NEONATAL MEDICINE, 2020, 33 (05) : 825 - 830
  • [38] Comparison of sonographic score and Bishop score in the prediction of successful labor induction in term patients: A prospective observational study
    Preethi, R. Udhaya
    Tripathy, Saswati
    CLINICAL EPIDEMIOLOGY AND GLOBAL HEALTH, 2024, 30
  • [39] Metabolomic Pathways Predicting Labor Dystocia by Maternal Body Mass Index
    Carlson, Nicole S.
    Frediani, Jennifer K.
    Corwin, Elizabeth J.
    Dunlop, Anne
    Jones, Dean
    AJP REPORTS, 2020, 10 (01): : E68 - E77
  • [40] Cervical length screening among low-risk women; relationship of body mass index on cervical length and risk of preterm birth
    Basri, Nurul Iftida
    Dasrilsyah, Rima Anggrena
    Jamil, Amilia Afzan Mohd
    Leong, Charmaine Sook Yee
    BMC PREGNANCY AND CHILDBIRTH, 2024, 24 (01)