Ten-year clinical follow-up after sirolimus-eluting stent implantation

被引:9
作者
Palhais, Nuno [1 ]
Arroyo, Diego [1 ]
Lehmann, Sonja [1 ]
Togni, Mario [1 ]
Kaufmann, Urs [1 ]
Puricel, Serban-Georges [1 ]
Stauffer, Jean-Christophe [1 ]
Goy, Jean-Jacques [1 ]
Cook, Stephane [1 ]
机构
[1] Univ & Hosp, Fribourg, Switzerland
关键词
NATIVE CORONARY-ARTERY; TARGET LESION REVASCULARIZATION; RANDOMIZED CONTROLLED-TRIAL; BARE-METAL STENTS; J-CYPHER REGISTRY; INTRAVASCULAR ULTRASOUND; NATURAL-HISTORY; RISK-FACTORS; THROMBOSIS; RESTENOSIS;
D O I
10.1016/j.ahj.2013.12.013
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Little is known on the "very" long-term incidence of major adverse cardiac events (MACE), target-lesion revascularization (TLR), target-vessel revascularization and stent thrombosis after sirolimus-eluting stent (SES) implantation. We present the first study to provide a 10-year clinical follow-up in an unselected patient population who underwent SES implantation. Methods and Results We ran a systematic 10-year clinical follow-up in a series of 200 consecutive patients treated with unrestricted SES implantation between April 2002 and April 2003 in two Swiss hospitals. Outcomes and follow-up were obtained in all 200 patients. The cumulative 10-year MACE rate was 47% with all-cause death of 20%, cardiac death of 9%, myocardial infarction of 7%, TLR and target-vessel revascularization of 8% and 11% respectively. Academic Research Consortium-defined "definite and probable" stent thrombosis-rate was 2.5%. TLR risk was maximal between 3 to 6 years. New lesion revascularization increased throughout the study period. Conclusion Incidence of TLR was maximal 3 to 6 years after SES implantation and decreased thereafter. MACE and non-TLR revascularization rates steadily increased during the complete follow-up underlining the progression of coronary artery disease.
引用
收藏
页码:893 / 899
页数:7
相关论文
共 33 条
[1]   Stent thrombosis late after implantation of first-generation drug-eluting stents - A cause for concern [J].
Camenzind, Edoardo ;
Steg, P. Gabriel ;
Wijns, William .
CIRCULATION, 2007, 115 (11) :1440-1455
[2]   Predictors of subacute stent thrombosis - Results of a systematic intravascular ultrasound study [J].
Cheneau, E ;
Leborgne, L ;
Mintz, GS ;
Kotani, J ;
Pichard, AD ;
Satler, LF ;
Canos, D ;
Castagna, M ;
Weissman, NJ ;
Waksman, R .
CIRCULATION, 2003, 108 (01) :43-47
[3]   Correlation of Intravascular Ultrasound Findings With Histopathological Analysis of Thrombus Aspirates in Patients With Very Late Drug-Eluting Stent Thrombosis [J].
Cook, Stephane ;
Ladich, Elena ;
Nakazawa, Gaku ;
Eshtehardi, Parham ;
Neidhart, Michel ;
Vogel, Rolf ;
Togni, Mario ;
Wenaweser, Peter ;
Billinger, Michael ;
Seiler, Christian ;
Gay, Steffen ;
Meier, Bernhard ;
Pichler, Werner J. ;
Jueni, Peter ;
Virmani, Renu ;
Windecker, Stephan .
CIRCULATION, 2009, 120 (05) :391-399
[4]   Clinical end points in coronary stent trials - A case for standardized definitions [J].
Cutlip, Donald E. ;
Windecker, Stephan ;
Mehran, Roxana ;
Boam, Ashley ;
Cohen, David J. ;
van Es, Gerrit-Anne ;
Steg, P. Gabriel ;
Morel, Marie-angele ;
Mauri, Laura ;
Vranckx, Pascal ;
McFadden, Eugene ;
Lansky, Alexandra ;
Hamon, Martial ;
Krucoff, Mitchell W. ;
Serruys, Patrick W. .
CIRCULATION, 2007, 115 (17) :2344-2351
[5]   Effectiveness of drug-eluting stents in patients with bare-metal in-stent restenosis -: Meta-analysis of randomized trials [J].
Dibra, Alban ;
Kastrati, Adrian ;
Alfonso, Fernando ;
Seyfarth, Melchior ;
Perez-Vizcayno, Maria-Jose ;
Mehilli, Julinda ;
Schomig, Albert .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2007, 49 (05) :616-623
[6]   Very Late Stent Thrombosis and Late Target Lesion Revascularization No End in Sight [J].
Faxon, David P. .
CIRCULATION, 2012, 125 (04) :562-564
[7]   The natural history of polymethylmethacrylate microspheres granulomas [J].
Gelfer, Allison ;
Carruthers, Alastair ;
Carruthers, Jean ;
Jang, Frances ;
Bernstein, Steven C. .
DERMATOLOGIC SURGERY, 2007, 33 (05) :614-620
[8]   Incidence of stent thrombosis and adverse cardiac events 5 years after sirolimus stent implantation in clinical practice [J].
Goy, Jean-Jacques ;
Urban, Philip ;
Kaufmann, Urs ;
Seydoux, Charles ;
De Benedetti, Edoardo ;
Berger, Alexandre .
AMERICAN HEART JOURNAL, 2009, 157 (05) :883-888
[9]   Late stent malapposition after drug-eluting stent implantation - An intravascular ultrasound analysis with long-term follow-up [J].
Hong, MK ;
Mintz, GS ;
Lee, CW ;
Park, DW ;
Park, KM ;
Lee, BK ;
Kim, YH ;
Song, JM ;
Han, KH ;
Kang, DH ;
Cheong, SS ;
Song, JK ;
Kim, JJ ;
Park, SW ;
Park, SJ .
CIRCULATION, 2006, 113 (03) :414-419
[10]   Incidence, predictors, and outcome of thrombosis after successful implantation of drug-eluting stents [J].
Iakovou, I ;
Schmidt, T ;
Bonizzoni, E ;
Ge, L ;
Sangiorgi, GM ;
Stankovic, G ;
Airoldi, F ;
Chieffo, A ;
Montorfano, M ;
Carlino, M ;
Michev, I ;
Corvaja, N ;
Briguori, C ;
Gerckens, U ;
Grube, E ;
Colombo, A .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2005, 293 (17) :2126-2130