Differentiating neutrophils using the optical coulter counter

被引:3
|
作者
Schonbrun, Ethan [1 ]
Di Caprio, Giuseppe [1 ]
机构
[1] Harvard Univ, Rowland Inst, Cambridge, MA 02142 USA
关键词
quantitative phase imaging; neutrophils; flow cytometry; morphology; fluorescence microscopy; MICROSCOPY; VOLUME; PHASE;
D O I
10.1117/1.JBO.20.11.111205
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We present an optofluidic measurement system that quantifies cell volume, dry mass, and nuclear morphology of neutrophils in high-throughput. While current clinical hematology analyzers can differentiate neutrophils from a blood sample, they do not give other quantitative information beyond their count. In order to better understand the distribution of neutrophil phenotypes in a blood sample, we perform two distinct multivariate measurements. In both measurements, white blood cells are driven through a microfluidic channel and imaged while in flow onto a color camera using a single exposure. In the first measurement, we quantify cell volume, scattering strength, and cell dry mass by combining quantitative phase imaging with dye exclusion cell volumetric imaging. In the second measurement, we quantify cell volume and nuclear morphology using a nucleic acid fluorescent stain. In this way, we can correlate cell volume to other cellular characteristics, which would not be possible using an electrical coulter counter. Unlike phase imaging or cell scattering analysis, the optical coulter counter is capable of quantifying cell volume virtually independent of the cell's refractive index and unlike optical tomography, measurements are possible on quickly flowing cells, enabling high-throughput. (C) 2015 Society of Photo-Optical Instrumentation Engineers (SPIE)
引用
收藏
页数:4
相关论文
共 50 条
  • [31] AN EVALUATION OF COULTER-S COUNTER
    SHARP, AA
    BALLARD, BCD
    JOURNAL OF CLINICAL PATHOLOGY, 1970, 23 (04) : 327 - &
  • [32] A SIMPLE DEVICE FOR CHECKING COULTER COUNTER
    UHLEY, HN
    LEWIS, AE
    BISKIND, GR
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1965, 44 (05) : 600 - &
  • [33] A microfluidic passive pumping Coulter counter
    McPherson, Amy L.
    Walker, Glenn M.
    MICROFLUIDICS AND NANOFLUIDICS, 2010, 9 (4-5) : 897 - 904
  • [34] A microfluidic passive pumping Coulter counter
    Amy L. McPherson
    Glenn M. Walker
    Microfluidics and Nanofluidics, 2010, 9 : 897 - 904
  • [35] EVALUATION OF COULTER COUNTER MODEL S
    BRITTIN, GM
    BRECHER, G
    JOHNSON, CA
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1969, 52 (06) : 679 - &
  • [36] Design and fabrication of a micromachined Coulter counter
    Koch, M
    Evans, AGR
    Brunnschweiler, A
    JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 1999, 9 (02) : 159 - 161
  • [37] EVALUATION OF COULTER COUNTER MODEL S
    BRITTIN, GM
    BRECHER, G
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1968, 50 (05) : 628 - &
  • [38] AN EVALUATION OF THE COULTER VCS DIFFERENTIAL COUNTER
    BARNARD, DF
    BARNARD, SA
    CARTER, AB
    PATTERSON, KG
    YARDUMIAN, A
    MACHIN, SJ
    CLINICAL AND LABORATORY HAEMATOLOGY, 1989, 11 (03): : 255 - 266
  • [39] THE COULTER-COUNTER LEUKOCYTE DIFFERENTIAL
    RICHARDSONJONES, A
    HELLMAN, R
    TWEDT, D
    BLOOD CELLS, 1985, 11 (02): : 203 - 240
  • [40] VOLUMETRIC CHANGES IN PHORBOL-MYRISTATE ACETATE ACTIVATED NEUTROPHILS - A RAPID AND SIMPLE ASSAY USING COULTER-COUNTER STKR AND STKS HEMATOLOGICAL ANALYZERS
    LIPPI, U
    BELLAVITE, P
    SCHINELLA, M
    NICOLI, M
    HAEMATOLOGICA, 1992, 77 (03) : 226 - 232