Assessment of laser speckle flowgraphy: Development of novel cutaneous blood flow measurement technique

被引:6
|
作者
Nagashima, Yoshinao [1 ,2 ]
Ohsugi, Yuko [1 ]
Niki, Yoshifumi [1 ]
Maeda, Kouji [1 ]
Okamoto, Takashi [2 ]
机构
[1] Kao Corp, Tokyo Res Labs, Tokyo 131, Japan
[2] Kyushu Inst Technol, Dept Syst Design & Informat, Fukuoka, Japan
来源
BIOPHOTONICS JAPAN 2015 | 2015年 / 9792卷
关键词
Cutaneous blood flow; laser speckle flowgraphy; mean blur rate; heartbeat; superimpose; CCD; strain-gauge plethysmography; venous occlusion; LIGHT-SCATTERING; MICROCIRCULATION;
D O I
10.1117/12.2203712
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Currently, there is no measurement device capable of comparing cutaneous blood flow among individuals. Thus, we experimentally prepared a laser speckle flowgraphy (LSFG) device, and investigated whether it can accurately measure cutaneous blood flow. The range in linearity of the positive correlation between the uniform circular motion speed (mm/sec) and mean blur rate (MBR), which is an index of cutaneous blood flow measured using LSFG, was investigated using a speed calibrator (Opal glass plate: OGP). Using strain-gauge plethysmography (SPG), measures the absolute value of blood flow (mL/min/100g), and LSFG, cutaneous blood flow was measured in the left finger in 50 healthy adults, and the correlation between the values measured by the two methods was investigated. An index of LSFG, MBR, was positively correlated with the turntable speed within a range from 10 to 450 mm/sec, suggesting that the MBR value may be useful as an index of the speed within this range. When cutaneous blood flow was measured at the fingertip using SPG and LSFG, a significant positive correlation was noted between the two measurement methods, suggesting that the MBR value with LSFG is a useful index of cutaneous blood flow. It is suggested that LSFG is a useful device for cutaneous blood flow evaluation because it allows comparison of cutaneous blood flow among individuals without the limitation of the measurement region noninvasively as well as continuously. Its applications in medical care and esthetic fields are expected.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Ocular blood flow values measured by laser speckle flowgraphy correlate with the postmenstrual age of normal neonates
    Matsumoto, Tadashi
    Itokawa, Takashi
    Shiba, Tomoaki
    Katayama, Yuuji
    Arimura, Tetsushi
    Hine, Kotaro
    Mizukaki, Norio
    Yoda, Hitoshi
    Hori, Yuichi
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2016, 254 (08) : 1631 - 1636
  • [22] Assessment of Choroidal Neovascularization Perfusion: A Pilot Study With Laser Speckle Flowgraphy
    Calzetti, Giacomo
    Mora, Paolo
    Favilla, Stefania
    Ottonelli, Giorgia
    Devincenzi, Giulia
    Carta, Arturo
    Tedesco, Salvatore
    Mursch-Edlmayr, Anna
    Garhoefer, Gerhard
    Gandolfi, Stefano
    Schmetterer, Leopold
    TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2020, 9 (05):
  • [23] Ocular blood flow values measured by laser speckle flowgraphy correlate with the postmenstrual age of normal neonates
    Tadashi Matsumoto
    Takashi Itokawa
    Tomoaki Shiba
    Yuuji Katayama
    Tetsushi Arimura
    Kotaro Hine
    Norio Mizukaki
    Hitoshi Yoda
    Yuichi Hori
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2016, 254 : 1631 - 1636
  • [24] Effect of anti-VEGF on retinal blood flow in diabetic mice using laser speckle flowgraphy
    Su, Zheng Zhe Steven
    Ang, Bryan Chin Hou
    Balne, Praveen Kumar
    Tun, Sai Bo Bo
    Htoon, Hla Myint
    Schmetterer, Leopold
    Barathi, Veluchamy Amutha
    Agrawal, Rupesh
    ACTA OPHTHALMOLOGICA, 2024, 102 (06) : e926 - e934
  • [25] Differences of Retinal Blood Flow Between Arteries and Veins Determined by Laser Speckle Flowgraphy in Healthy Subjects
    Iwase, Takeshi
    Ra, Eimei
    Yamamoto, Kentaro
    Kaneko, Hiroki
    Ito, Yasuki
    Terasaki, Hiroko
    MEDICINE, 2015, 94 (33) : e1256
  • [26] Effects of water drinking test on ocular blood flow waveform parameters: A laser speckle flowgraphy study
    Bhatti, Mehwish Saba
    Tang, Tong Boon
    Laude, Augustinus
    PLOS ONE, 2017, 12 (07):
  • [27] Analysis of Blood Flow in the Macula and Optic Nerve Head in Healthy Young Volunteers Using Laser Speckle Flowgraphy
    Bajka, Anahita
    Foa, Nastasia
    Sidhu, Sophia
    Rejdak, Magdalena
    Said, Sadiq
    Wiest, Maximilian Robert Justus
    Hamann, Timothy
    Blaser, Frank
    Zweifel, Sandrine Anne
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2023, 240 (04) : 608 - 612
  • [28] Reduced blood flow by laser speckle flowgraphy after 125I-plaque brachytherapy for uveal melanoma
    Tamplin, Michelle R.
    Wang, Jui-Kai
    Vitale, Anthony H.
    Hashimoto, Ryuya
    Garvin, Mona K.
    Binkley, Elaine M.
    Hyer, Daniel E.
    Buatti, John M.
    Boldt, H. Culver
    Kardon, Randy H.
    Grumbach, Isabella M.
    BMC OPHTHALMOLOGY, 2022, 22 (01)
  • [29] Reduced blood flow by laser speckle flowgraphy after 125I-plaque brachytherapy for uveal melanoma
    Michelle R. Tamplin
    Jui-Kai Wang
    Anthony H. Vitale
    Ryuya Hashimoto
    Mona K. Garvin
    Elaine M. Binkley
    Daniel E. Hyer
    John M. Buatti
    H. Culver Boldt
    Randy H. Kardon
    Isabella M. Grumbach
    BMC Ophthalmology, 22
  • [30] Evaluation of Fundus Blood Flow in Normal Individuals and Patients with Internal Carotid Artery Obstruction Using Laser Speckle Flowgraphy
    Shinohara, Yoichiro
    Kashima, Tomoyuki
    Akiyama, Hideo
    Shimoda, Yukitoshi
    Li, Danjie
    Kishi, Shoji
    PLOS ONE, 2017, 12 (01):