Prospects of Improving the Indoor Air Quality in Classrooms by Reactivating Historic Ventilation Stacks

被引:0
|
作者
Hellwig, Runa T. [1 ,2 ]
Sedlmeier, Michael [1 ]
Tanzer, Christian [1 ]
机构
[1] Augsburg Univ Appl Sci, Unit E2D Energy Efficiency Design, Augsburg, Germany
[2] Natl Univ Singapore, Dept Bldg, Sch Design & Environm, Cluster Solar & Energy Efficient Bldg,Solar Energ, Singapore 11757, Singapore
关键词
school building; ventilation stack; indoor air quality; historic ventilation system;
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Stack ventilation systems were installed in German schools constructed around 1900 and are no longer in operation. The aim of this study was to show how reactivating these systems could improve the indoor air quality in classrooms. Ventilation stacks were reactivated in three classrooms in a school while a fourth classroom, which was naturally ventilated via openable windows, served as the reference case. All classrooms were measured for carbon dioxide levels, air temperature and relative humidity. During winter, 50% of all measured carbon dioxide values in the classroom with natural ventilation using windows were higher than 1800 ppm. All classrooms with stack ventilation showed median values of 1600 and 1350 ppm. In these classrooms, the volumetric flow rate per person in winter (14 m(3)/(h.pers)) was approximately seven times higher compared to the classroom with window ventilation (2 m(3)/(h.pers)). The supply stacks provided a preheating effect of 0.5 to 0.7 K/m. Effects of summer flow reversal were found in both of the classrooms with exhaust and supply ventilation stacks. Reactivating ventilation stacks provides the potential to improve indoor air quality in classrooms. Some adjustment of the systems, such as adding automated dampers to close the stacks at night and during flow reversal in summer, could allow the systems to meet today's hygienic and comfort requirements and turn them into modern low energy consuming systems.
引用
收藏
页码:141 / 152
页数:12
相关论文
共 50 条
  • [21] A Campus Sustainability Initiative: Indoor Air Quality Monitoring in Classrooms
    Marchetti, N.
    Cavazzini, A.
    Pasti, L.
    Catani, M.
    Malagu, C.
    Guidi, V.
    2015 18TH AISEM ANNUAL CONFERENCE, 2015,
  • [22] From spontaneous to strategic natural window ventilation: Improving indoor air quality in Swiss schools
    Vassella, Claudia C.
    Koch, Jeremy
    Henzi, Alexander
    Jordan, Alexander
    Waeber, Roger
    Iannaccone, Reto
    Charriere, Roland
    INTERNATIONAL JOURNAL OF HYGIENE AND ENVIRONMENTAL HEALTH, 2021, 234
  • [23] Ventilation for good indoor air quality and energy efficiency
    Awbi, Hazim B.
    SUSTAINABLE SOLUTIONS FOR ENERGY AND ENVIRONMENT, EENVIRO 2016, 2017, 112 : 277 - 286
  • [24] Discussion on Ventilation Requirement for Meeting Indoor Air Quality
    Lin, Mengjie
    Liu, Qinqin
    Peng, Zimao
    ADVANCES IN CIVIL AND INDUSTRIAL ENGINEERING IV, 2014, 580-583 : 2471 - 2474
  • [25] BUILDING DESIGN AND INDOOR AIR QUALITY - EXPERIENCE AND PROSPECTS
    Kotzias, Dimitris
    Pilidis, Georgios
    FRESENIUS ENVIRONMENTAL BULLETIN, 2017, 26 (01): : 323 - 326
  • [26] Statistical analysis of natural and mechanical ventilation performance in improving indoor air quality, thermal comfort, and perceived air quality in a healthcare facility
    Gholampour, Marzieh
    Taghipour, Malihe
    Tahavvor, Alireza
    Jafari, Saeed
    INTERNATIONAL JOURNAL OF VENTILATION, 2024,
  • [27] Soft Ionization: Improving Indoor Air Quality
    Farahi, Faramarz
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2023, 59 (05) : 5580 - 5586
  • [28] Ventilation to maintain indoor air quality in smoking rooms
    Snelson, D. G.
    Al-Madfai, H.
    Geens, A. J.
    AIR POLLUTION XVIII, 2010, 136 : 339 - 348
  • [29] EFFECTIVENESS OF INDOOR AIR QUALITY IMPROVEMENT WITH OUTDOOR AIR FOR BUILDING VENTILATION
    Wang, J.
    Zhang, X.
    Zhou, X.
    7TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATING AND AIR CONDITIONING, PROCEEDINGS OF ISHVAC 2011, VOLS I-IV, 2011, : 417 - 421
  • [30] Improving indoor air quality with textile materials
    Gazioğlu Rüzgar D.
    Altun Ş.
    Altun, Şule (sule.altun@btu.edu.tr), 1600, Chamber of Textile Engineers (23): : 288 - 296