Prospects of Improving the Indoor Air Quality in Classrooms by Reactivating Historic Ventilation Stacks

被引:0
|
作者
Hellwig, Runa T. [1 ,2 ]
Sedlmeier, Michael [1 ]
Tanzer, Christian [1 ]
机构
[1] Augsburg Univ Appl Sci, Unit E2D Energy Efficiency Design, Augsburg, Germany
[2] Natl Univ Singapore, Dept Bldg, Sch Design & Environm, Cluster Solar & Energy Efficient Bldg,Solar Energ, Singapore 11757, Singapore
关键词
school building; ventilation stack; indoor air quality; historic ventilation system;
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Stack ventilation systems were installed in German schools constructed around 1900 and are no longer in operation. The aim of this study was to show how reactivating these systems could improve the indoor air quality in classrooms. Ventilation stacks were reactivated in three classrooms in a school while a fourth classroom, which was naturally ventilated via openable windows, served as the reference case. All classrooms were measured for carbon dioxide levels, air temperature and relative humidity. During winter, 50% of all measured carbon dioxide values in the classroom with natural ventilation using windows were higher than 1800 ppm. All classrooms with stack ventilation showed median values of 1600 and 1350 ppm. In these classrooms, the volumetric flow rate per person in winter (14 m(3)/(h.pers)) was approximately seven times higher compared to the classroom with window ventilation (2 m(3)/(h.pers)). The supply stacks provided a preheating effect of 0.5 to 0.7 K/m. Effects of summer flow reversal were found in both of the classrooms with exhaust and supply ventilation stacks. Reactivating ventilation stacks provides the potential to improve indoor air quality in classrooms. Some adjustment of the systems, such as adding automated dampers to close the stacks at night and during flow reversal in summer, could allow the systems to meet today's hygienic and comfort requirements and turn them into modern low energy consuming systems.
引用
收藏
页码:141 / 152
页数:12
相关论文
共 50 条
  • [1] The Role of Portable Air Purifiers and Effective Ventilation in Improving Indoor Air Quality in University Classrooms
    Aldekheel, Mohammad
    Altuwayjiri, Abdulmalik
    Tohidi, Ramin
    Farahani, Vahid Jalali
    Sioutas, Constantinos
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2022, 19 (21)
  • [2] Indoor Air Quality Performance of Ventilation Systems in Classrooms
    Moon, Hyeun Jun
    Sohn, Jong-Ryeul
    Hwang, Taeyon
    JOURNAL OF ASIAN ARCHITECTURE AND BUILDING ENGINEERING, 2016, 15 (02) : 343 - 348
  • [3] The Effect of Ventilation Strategies on Indoor Air Quality and Energy Consumptions in Classrooms
    Stabile, Luca
    Massimo, Angelamaria
    Canale, Laura
    Russi, Aldo
    Andrade, Alexandro
    Dell'Isola, Marco
    BUILDINGS, 2019, 9 (05)
  • [4] Inadequacy of air purifier for indoor air quality improvement in classrooms without external ventilation
    Choe, Youngtae
    Shin, Jun-shup
    Park, Jinhyeon
    Kim, Eunchae
    Oh, Narae
    Min, Kihong
    Kim, Dongjun
    Sung, Kyunghwa
    Cho, Mansu
    Yang, Wonho
    BUILDING AND ENVIRONMENT, 2022, 207
  • [5] A comprehensive analysis of the intervention of a fresh air ventilation system on indoor air quality in classrooms
    Chen, Yu-Hao
    Tu, Yen-Pei
    Sung, Shih-Yi
    Weng, Wei-Cheng
    Huang, Hsiao-Lin
    Tsai, Ying, I
    ATMOSPHERIC POLLUTION RESEARCH, 2022, 13 (04)
  • [6] Indoor Air Quality in UK School Classrooms Ventilated by Natural Ventilation Windcatchers
    Jones, Benjamin M.
    Kirby, Ray
    INTERNATIONAL JOURNAL OF VENTILATION, 2012, 10 (04) : 323 - 337
  • [7] A ventilation intervention study in classrooms to improve indoor air quality: the FRESH study
    Jeannette TM Rosbach
    Machiel Vonk
    Frans Duijm
    Jan T van Ginkel
    Ulrike Gehring
    Bert Brunekreef
    Environmental Health, 12
  • [8] A ventilation intervention study in classrooms to improve indoor air quality: the FRESH study
    Rosbach, Jeannette T. M.
    Vonk, Machiel
    Duijm, Frans
    van Ginkel, Jan T.
    Gehring, Ulrike
    Brunekreef, Bert
    ENVIRONMENTAL HEALTH, 2013, 12
  • [9] Year long monitoring of indoor air quality and ventilation in school classrooms in Victoria, Australia
    Rajagopalan, Priyadarsini
    Andamon, Mary Myla
    Woo, Jin
    ARCHITECTURAL SCIENCE REVIEW, 2022, 65 (01) : 1 - 13
  • [10] Ventilation and Indoor Air Quality
    Kumar, Ashok
    Moreno-Rangel, Alejandro
    Khan, M. Amirul, I
    Piasecki, Michal
    ATMOSPHERE, 2022, 13 (10)