Design Circuit for the single-lens high-definition imaging system

被引:0
作者
Ren, Xiang [1 ]
Huang, Yule [1 ]
Li, Chijun [1 ]
Yang, Kai [1 ]
Zou, Jiebin [1 ]
Kong, Jiayong [1 ]
Cai, Jing [1 ]
机构
[1] Foshan Univ, Sch Phys & Optoelect Engn, Foshan 528000, Peoples R China
来源
PROCEEDINGS OF THE 2016 5TH INTERNATIONAL CONFERENCE ON MEASUREMENT, INSTRUMENTATION AND AUTOMATION (ICMIA 2016) | 2016年 / 138卷
关键词
Chromatism; High-definition imaging system; Single lens; Double light;
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
We proposed a method to resolve the problem of optical system defocus phenomenon by using the chromatic aberration of the single lens optical imaging system through reverse thinking. Furthermore, we designed and built the production which use SDRAM to collect data for CMOS image information literacy which was connected to the computer via USB transmission and the self-made circuit based on FPGA. Finally, some high-definition images can be obtained by using LabVIEW and MATLAB software programming to realize the data conversion, function calls, and image processing. The production is referred to the camera imaging system, specially, it can involves the problem which needs to solve the single lens of the depth of field and expand the depth of field in imaging system.
引用
收藏
页码:696 / 700
页数:5
相关论文
共 5 条
[1]  
li D. H., 2013, MODERN ENG OPTICS
[2]  
Li LZ, 2010, LECT NOTES ARTIF INT, V6216, P1
[3]  
Liu C., 2010, APPL OPTICS
[4]  
Sun H., 2009, J ELECT SCI TECHNOLO
[5]  
Zhong X., 2008, MODERN OPTICS, V1, P3436