POINT CLOUD REFINEMENT WITH A TARGET-FREE INTRINSIC CALIBRATION OF A MOBILE MULTI-BEAM LIDAR SYSTEM

被引:3
作者
Nouira, H. [1 ]
Deschaud, J. E. [1 ]
Goulette, F. [1 ]
机构
[1] PSL Res Univ, MINES ParisTech, CAOR Ctr Robot, 60 Bd St Michel, F-75006 Paris, France
来源
XXIII ISPRS CONGRESS, COMMISSION III | 2016年 / 41卷 / B3期
关键词
LIDAR; Intrinsic; Calibration; Mobile Mapping; 3D; Automatic; Computer Processing; Velodyne;
D O I
10.5194/isprsarchives-XLI-B3-359-2016
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
LIDAR sensors are widely used in mobile mapping systems. The mobile mapping platforms allow to have fast acquisition in cities for example, which would take much longer with static mapping systems. The LIDAR sensors provide reliable and precise 3D information, which can be used in various applications: mapping of the environment; localization of objects; detection of changes. Also, with the recent developments, multi-beam LIDAR sensors have appeared, and are able to provide a high amount of data with a high level of detail. A mono-beam LIDAR sensor mounted on a mobile platform will have an extrinsic calibration to be done, so the data acquired and registered in the sensor reference frame can be represented in the body reference frame, modeling the mobile system. For a multi-beam LIDAR sensor, we can separate its calibration into two distinct parts: on one hand, we have an extrinsic calibration, in common with mono-beam LIDAR sensors, which gives the transformation between the sensor cartesian reference frame and the body reference frame. On the other hand, there is an intrinsic calibration, which gives the relations between the beams of the multi-beam sensor. This calibration depends on a model given by the constructor, but the model can be non optimal, which would bring errors and noise into the acquired point clouds. In the litterature, some optimizations of the calibration parameters are proposed, but need a specific routine or environment, which can be constraining and time-consuming. In this article, we present an automatic method for improving the intrinsic calibration of a multi-beam LIDAR sensor, the Velodyne HDL-32E. The proposed approach does not need any calibration target, and only uses information from the acquired point clouds, which makes it simple and fast to use. Also, a corrected model for the Velodyne sensor is proposed. An energy function which penalizes points far from local planar surfaces is used to optimize the different proposed parameters for the corrected model, and we are able to give a confidence value for the calibration parameters found. Optimization results on both synthetic and real data are presented.
引用
收藏
页码:359 / 366
页数:8
相关论文
共 13 条
  • [1] LIDAR Velodyne HDL-64E Calibration Using Pattern Planes
    Atanacio-Jimenez, Gerardo
    Gonzalez-Barbosa, Jose-Joel
    Hurtado-Ramos, Juan B.
    Ornelas-Rodriguez, Francisco J.
    Jimenez-Hernandez, Hugo
    Garcia-Ramirez, Teresa
    Gonzalez-Barbosa, Ricardo
    [J]. INTERNATIONAL JOURNAL OF ADVANCED ROBOTIC SYSTEMS, 2011, 8 (05): : 70 - 82
  • [2] Chan T O, 2013, 8 INT S MOB MAPP TEC
  • [3] Automatic In Situ Calibration of a Spinning Beam LiDAR System in Static and Kinematic Modes
    Chan, Ting On
    Lichti, Derek D.
    [J]. REMOTE SENSING, 2015, 7 (08) : 10480 - 10500
  • [4] Static Calibration and Analysis of the Velodyne HDL-64E S2 for High Accuracy Mobile Scanning
    Glennie, Craig
    Lichti, Derek D.
    [J]. REMOTE SENSING, 2010, 2 (06): : 1610 - 1624
  • [5] Huang PS, 2013, 2013 IEEE 11TH IVMSP WORKSHOP: 3D IMAGE/VIDEO TECHNOLOGIES AND APPLICATIONS (IVMSP 2013)
  • [6] Levinson J., 2010, INT S EXP ROB
  • [7] Lin CC, 2013, 2013 IEEE/SICE INTERNATIONAL SYMPOSIUM ON SYSTEM INTEGRATION (SII), P677, DOI 10.1109/SII.2013.6776618
  • [8] Muhammad N, 2010, IEEE INT C INT ROBOT
  • [9] Narayana K. S., 2009, 6 INT S MOB MAPP TEC
  • [10] Nouira H., 2015, ISPRS GEOSPATIAL WEE