Determination of ultra trace concentrations of selenium using the GFAAS technique following on-line electrochemical pre-concentration on a gold-coated porous carbon electrode
被引:14
作者:
Cacho, Frantisek
论文数: 0引用数: 0
h-index: 0
机构:
Slovak Univ Technol Bratislava, Fac Chem & Food Technol, Inst Analyt Chem, Bratislava 81237, SlovakiaSlovak Univ Technol Bratislava, Fac Chem & Food Technol, Inst Analyt Chem, Bratislava 81237, Slovakia
Cacho, Frantisek
[1
]
Jankuv, Lukas
论文数: 0引用数: 0
h-index: 0
机构:
Slovak Univ Technol Bratislava, Fac Chem & Food Technol, Inst Analyt Chem, Bratislava 81237, SlovakiaSlovak Univ Technol Bratislava, Fac Chem & Food Technol, Inst Analyt Chem, Bratislava 81237, Slovakia
Jankuv, Lukas
[1
]
Lauko, Lukas
论文数: 0引用数: 0
h-index: 0
机构:
Slovak Univ Technol Bratislava, Fac Chem & Food Technol, Inst Analyt Chem, Bratislava 81237, SlovakiaSlovak Univ Technol Bratislava, Fac Chem & Food Technol, Inst Analyt Chem, Bratislava 81237, Slovakia
Lauko, Lukas
[1
]
Kroliak, Martin
论文数: 0引用数: 0
h-index: 0
机构:
Slovak Univ Technol Bratislava, Fac Chem & Food Technol, Inst Analyt Chem, Bratislava 81237, SlovakiaSlovak Univ Technol Bratislava, Fac Chem & Food Technol, Inst Analyt Chem, Bratislava 81237, Slovakia
Kroliak, Martin
[1
]
Manova, Alena
论文数: 0引用数: 0
h-index: 0
机构:
Slovak Univ Technol Bratislava, Fac Chem & Food Technol, Inst Analyt Chem, Bratislava 81237, SlovakiaSlovak Univ Technol Bratislava, Fac Chem & Food Technol, Inst Analyt Chem, Bratislava 81237, Slovakia
Manova, Alena
[1
]
Beinrohr, Ernest
论文数: 0引用数: 0
h-index: 0
机构:
Slovak Univ Technol Bratislava, Fac Chem & Food Technol, Inst Analyt Chem, Bratislava 81237, SlovakiaSlovak Univ Technol Bratislava, Fac Chem & Food Technol, Inst Analyt Chem, Bratislava 81237, Slovakia
Beinrohr, Ernest
[1
]
机构:
[1] Slovak Univ Technol Bratislava, Fac Chem & Food Technol, Inst Analyt Chem, Bratislava 81237, Slovakia
In this work the possibility of determination of selenium in water samples was studied by on-line coupling of electrochemical pre-concentration flow through unit and GFAAS. The pre-concentration unit was created from a commercial electrochemical flow through analyser EcaFlow (Istran Ltd.) and a special two-electrode electrochemical flow through cell. The pre-concentration cell consisted of a working electrode made of gold-coated porous carbon and auxiliary electrode made of a Pt-wire. The pre-concentration unit was connected with electrothermal atomisers through 6-way valve with sampling loop. Using the proposed on-line coupling the limit of detection reached 0.01 mu g L-1 for a 10 mL sample. The total linear range was between 0.03 and 10 mu g L-1. From the number of ions tested only PO43- ions reduced the signal by about 10% for 50-fold excess. Using this method it was possible to determine Se (IV) or the total inorganic selenium following reduction of Se (VI) by boiling the sample in HCl. The procedure was validated by analysing reference materials and a variety of water samples. A good agreement with the results of ICP-MS was achieved for all samples. (C) 2013 Elsevier B.V. All rights reserved.