Experimental investigation of natural convection heat exchange within a physical model of the manifold chamber of a thermosyphon heat-pipe evacuated tube solar water heater

被引:22
作者
Redpath, David A. G. [1 ]
Eames, Philip C. [2 ]
Lo, Steve N. G. [1 ]
Griffiths, Phillip W. [1 ]
机构
[1] Univ Ulster, Ctr Sustainable Technol, Sch Built Environm, Belfast BT37 0QB, Antrim, North Ireland
[2] Univ Warwick, Warwick Inst Sustainable Energy & Resources, Coventry CV4 7AL, W Midlands, England
关键词
Evacuated; Interacting fluid flows; Heat-pipe; Natural convection; HORIZONTAL CYLINDERS; ARRAYS;
D O I
10.1016/j.solener.2009.01.002
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The high capital costs associated with heat-pipe evacuated tube solar water heating systems can be reduced by replacing forced circulation with thermosyphon circulation. Currently research on thermosyphon heat-pipe evacuated tube solar water heaters is limited. An experimental investigation of the natural convective heat exchange regime that exists within the manifold chamber of a proprietary heat-pipe evacuated tube solar water was undertaken. This paper presents experimental data from a heat-pipe Evacuated Tube Solar Water Heater (ETSWH) subjected to the Northern Maritime Climate at the University of Ulster's outdoor solar testing facility located at the Jordanstown campus. The thermal performance of this across solar noon (+/- 30 min) was experimentally determined to be comparable to two physical laboratory 10 pin-fin model manifolds constructed to the same dimensions and geometry as the manifold chamber of the heat-pipe ETSWH when operated under steady laboratory conditions. When the surface temperatures of the pin-fins (simulated condensers) in the model manifold were normalised with respect to the lowest most pin-fin in the array the influence of buoyant flow was observed. Similarly to related studies in this field it was found that normalised surface temperatures on downstream pin-fins do not increase monotonically as would be expected if no interactions occur. It was found that at the pin-fin diameter to pitch used in the model manifold that normalised surface temperatures decrease at certain points in the array due to the action of buoyant flow generated from upstream pin-fins which increased heat transfer. Two-dimensional Particle Imaging Velocimetry (2D-PIV) was used to visualise the thermosyphon fluid flow regime. It was observed that the fluid flow regime varied across the model due to interactions between the fluid, chamber walls and pin-fins. (C) 2009 Elsevier Ltd. All rights reserved.
引用
收藏
页码:988 / 997
页数:10
相关论文
共 15 条
[1]  
[Anonymous], 2000, REP REN EN RES
[2]   Correlating equations for free convection heat transfer from horizontal isothermal cylinders set in a vertical array [J].
Corcione, M .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2005, 48 (17) :3660-3673
[3]   Interactive free convection from a pair of vertical tube-arrays at moderate Rayleigh numbers [J].
Corcione, Massimo .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2007, 50 (5-6) :1061-1074
[4]   NATURAL-CONVECTION FROM HORIZONTAL CYLINDERS IN INTERACTING FLOW-FIELDS [J].
FAROUK, B ;
GUCERI, SI .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1983, 26 (02) :231-243
[5]  
Gebhart B., 1988, Buoyancy-Induced Flows and Transport
[6]  
*INCR, 2002, INTRO HEAT TRANSFER
[7]   INTERACTIONS IN NATURAL CONVECTION FROM AN ARRAY OF HEATED ELEMENTS, EXPERIMENTAL [J].
LIEBERMAN, J ;
GEBHART, B .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1969, 12 (11) :1385-+
[8]   ARRAYS OF HEATED HORIZONTAL CYLINDERS IN NATURAL-CONVECTION [J].
MARSTERS, GF .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1972, 15 (05) :921-&
[9]  
Morgan V. T., 1975, Adv. Heat Transf, V11, P199, DOI DOI 10.1016/S0065-2717(08)70075-3
[10]   LONG-TERM PERFORMANCE OF EVACUATED TUBULAR SOLAR WATER HEATERS IN SYDNEY, AUSTRALIA [J].
MORRISON, GL ;
TRAN, NH ;
MCKENZIE, DR ;
ONLEY, IC ;
HARDING, GL ;
COLLINS, RE .
SOLAR ENERGY, 1984, 32 (06) :785-791