Negative-Pressure Wound Therapy II: Negative-Pressure Wound Therapy and Increased Perfusion. Just an Illusion?

被引:131
作者
Kairinos, Nicolas [1 ]
Voogd, Anda M.
Botha, Pieter H.
Kotze, Tessa
Kahn, Delawir
Hudson, Donald A.
Solomons, Michael
机构
[1] Groote Schuur Hosp, Dept Plast Surg, ZA-7925 Cape Town, South Africa
关键词
VACUUM-ASSISTED CLOSURE; PERISTERNAL THORACIC WALL; BLOOD-FLOW;
D O I
10.1097/PRS.0b013e318196b97b
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: A recent study demonstrated that negative-pressure wound therapy increases underlying tissue pressure. This finding is incongruous with studies using laser Doppler that show that perfusion is immediately increased on initiation of suction. This study investigated perfusion in negative-pressure wound therapy using two alternative modalities. Methods: Radioisotope perfusion imaging was used to determine perfusion beneath circumferential negative-pressure wound therapy dressings on 20 healthy hands (n = 20). Ten hands received suction pressures of -400 mmHg and 10 received -125 mmHg, with the contralateral hand used as a control without any suction. Transcutaneous partial pressure of oxygen was used to determine perfusion beneath noncircumferential negative-pressure wound therapy dressings on 12 healthy legs (n = 12), with each volunteer being sequentially randomized to receive suction pressures of -400 and -125 mmHg, respectively. Results: Tissues undergoing circumferential negative-pressure wound therapy demonstrated a mean reduction in perfusion of 40 +/- 11.5 percent (p < 0.0005) and 17 +/- 8.9 percent (p < 0.0005) at suction pressures of -400 mmHg and -125 mmHg, respectively. Perfusion reduction at -400 mmHg was significantly greater than at -125 mmHg (p < 0.015). In the noncircumferential negative-pressure wound therapy group, there was a mean reduction in transcutaneous partial pressure of oxygen of 7.35 +/- 7.4 mmHg (p < 0.0005) and 5.10 +/- 7.4 mmHg(p < 0.0005) at suction pressures of -400 mmHg and -125 mmHg, respectively. There was a tendency for greater reductions in the -400 mmHg group, but this was not significantly different from the -125 mmHg group (p = 0.07). Conclusions: These findings demonstrate that perfusion beneath negative-pressure wound therapy decreases for increasing suction pressure. Thus, it is suggested that negative-pressure wound therapy should be used with caution on tissues with compromised vascularity, particularly when used circumferentially. (Plast. Reconstr. Surg. 123: 601, 2009.)
引用
收藏
页码:601 / 612
页数:12
相关论文
共 15 条
[11]   The revised "reconstructive ladder" and its applications for high-energy injuries to the extremities [J].
Ullmann, Y ;
Fodor, L ;
Ramon, Y ;
Soudry, M ;
Lerner, L .
ANNALS OF PLASTIC SURGERY, 2006, 56 (04) :401-405
[12]   Mechanisms and clinical applications of the vacuum-assisted closure (VAC) device - A review [J].
Venturi, ML ;
Attinger, CE ;
Mesbahi, AN ;
Hess, CL ;
Graw, KS .
AMERICAN JOURNAL OF CLINICAL DERMATOLOGY, 2005, 6 (03) :185-194
[13]   Effects of vacuum-assisted closure therapy on inguinal wound edge microvascular blood flow [J].
Wackenfors, A ;
Sjögren, J ;
Gustafsson, R ;
Algotsson, L ;
Ingemansson, R ;
Malmsjö, M .
WOUND REPAIR AND REGENERATION, 2004, 12 (06) :600-606
[14]   Blood flow responses in the peristernal thoracic wall during vacuum-assisted closure therapy [J].
Wackenfors, A ;
Gustafsson, R ;
Sjögren, J ;
Algotsson, L ;
Ingemansson, R ;
Malmsjö, M .
ANNALS OF THORACIC SURGERY, 2005, 79 (05) :1724-1731
[15]   Experimental principles of the VAC®-therapy -: Pressure values in superficial soft ttissue and the applied foam [J].
Willy, C ;
von Thun-Hohenstein, H ;
von Lübken, F ;
Weymouth, M ;
Kossmann, T ;
Engelhardt, M .