Application of gradient programs for the determination of underivatized amino acids and small peptides in reversed-phase high-performance liquid chromatography with contactless conductivity detection

被引:26
作者
Kuban, Pavel [1 ]
Hauser, Peter C. [1 ]
机构
[1] Univ Basel, Dept Chem, CH-4004 Basel, Switzerland
关键词
amino acids; peptides; high-performance liquid chromatography; contactless conductivity detection; gradient elution;
D O I
10.1016/j.chroma.2006.06.046
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The application of gradient methods in HPLC determinations with capacitively coupled contactless conductivity detection was successfully demonstrated for non-UV-absorbing amino acids as well as for small peptides as analytes. The drift in baseline which is caused by the change in the conductivity of the mobile phase during the elution could be minimized by careful optimization of the composition of the mobile phase. For such conditions the remaining baseline drift could be corrected for either by subtraction of a blank chromatogram or by baseline normalization using a software package for chromatographic data processing. Reverse phase separations were carried out using aqueous eluents containing either methanol or acetonitrile and acetic acid or trifluoroacetic acid. Detection limits between 1 and 40 mu M were achieved for the amino acids and the di- and tri-peptides investigated. The reproducibilities for the peak areas were typically found to be about 2% and good linearity was obtained for the concentration range tested (up to 1000 mu M). (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:97 / 104
页数:8
相关论文
共 30 条
[1]   Understanding capacitively coupled contactless conductivity detection in capillary and microchip electrophoresis. Part 1. Fundamentals [J].
Brito-Neto, JGA ;
da Silva, JAF ;
Blanes, L ;
do Lago, CL .
ELECTROANALYSIS, 2005, 17 (13) :1198-1206
[2]   Determination of 20 underivatized proteinic amino acids by ion-pairing chromatography and pneumatically assisted electrospray mass spectrometry [J].
Chaimbault, P ;
Petritis, K ;
Elfakir, C ;
Dreux, M .
JOURNAL OF CHROMATOGRAPHY A, 1999, 855 (01) :191-202
[3]   Ion-pair chromatography on a porous graphitic carbon stationary phase for the analysis of twenty underivatized protein amino acids [J].
Chaimbault, P ;
Petritis, K ;
Elfakir, C ;
Dreux, M .
JOURNAL OF CHROMATOGRAPHY A, 2000, 870 (1-2) :245-254
[4]   Separation of twenty underivatized essential amino acids by capillary zone electrophoresis with contactless conductivity detection [J].
Coufal, P ;
Zuska, J ;
van de Goor, T ;
Smith, V ;
Gas, B .
ELECTROPHORESIS, 2003, 24 (04) :671-677
[5]  
da Silva JAF, 1998, ANAL CHEM, V70, P4339
[6]   SEPARATION AND INDIRECT DETECTION OF AMINO-ACIDS BY REVERSED-PHASE ION-PAIR CHROMATOGRAPHY [J].
ESLAMI, M ;
HASHEMI, P ;
SARBOLOUKI, MN .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1993, 31 (11) :480-485
[7]   A contactless conductivity detection cell for flow injection analysis:: Determination of total inorganic carbon [J].
Hohercáková, Z ;
Opekar, F .
ANALYTICA CHIMICA ACTA, 2005, 551 (1-2) :132-136
[8]   Evaluation of contactless conductivity detection for the determination of UV absorbing and non-UV absorbing species in reversed-phase high-performance liquid chromatography [J].
Kubán, P ;
Abad-Villar, EM ;
Hauser, PC .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1107 (1-2) :159-164
[9]   Fundamental aspects of contactless conductivity detection for capillary electrophoresis. Part I: Frequency behavior and cell geometry [J].
Kuban, P ;
Hauser, PC .
ELECTROPHORESIS, 2004, 25 (20) :3387-3397
[10]   Fundamental aspects of contactless conductivity detection for capillary electrophoresis. Part II: Signal-to-noise ratio and stray capacitance [J].
Kuban, P ;
Hauser, PC .
ELECTROPHORESIS, 2004, 25 (20) :3398-3405