A theoretical model to predict the in vitro performance of hemodiafilters

被引:56
作者
Legallais, C
Catapano, G
von Harten, B
Baurmeister, U
机构
[1] Univ Technol Compiegne, CNRS, UMR 6600, F-60205 Compiegne, France
[2] Univ Calabria, Dept Chem & Mat Engn, I-87030 Arcavacata Di Rende, CS, Italy
[3] Membrane GmbH, D-42289 Wuppertal, Germany
关键词
hemodiafiltration; mass; membrane; momentum; transport;
D O I
10.1016/S0376-7388(99)00297-5
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
In vitro tests with saline or plasma replacing the blood are generally used in the development of membranes and membrane modules for hemodiafiltration (HDF) and for quality control purposes. Theoretical models predicting performance of a hemodiafilter based on module geometry, membrane properties and operating conditions are needed, but are not yet available, to distinguish to what extent membrane properties and module fluid dynamics both affect module clearance. In this paper, we report on the development of a simple predictive model for hemodiafiltration which still accounts for those phenomena that most profoundly affect performance of hemodiafilters, such as: the dependence of mass transport coefficients on the actual flow conditions; concentration polarization; the actual water filtration flux along the hemodiafilter length. The model was validated with respect to data in literature. Model predictions for low to high molecular weight solute clearance were within 10% of experimental data when saline replaces the blood and within 20% when plasma replaces the blood, at blood flow rates ranging from 100 to 500 ml/min and net overall filtration flow rates from 0 to 60 ml/min. Under all conditions, the model predicted clearances were in better agreement with experimental data than those predicted by other, non-predictive models for HDF. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:3 / 15
页数:13
相关论文
共 23 条
[1]   On-line hemodiafiltration with pre- and postdilution: A comparison of efficacy [J].
Ahrenholz, P ;
Winkler, RE ;
Ramlow, W ;
Tiess, M ;
Muller, W .
INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1997, 20 (02) :81-90
[2]  
[Anonymous], 1963, HDB PHYSL
[3]  
Blatt W, 1970, MEMBRANE SCI TECHNOL, P47, DOI 10.1007/978-1-4684-1851-4_4
[4]  
Bosch T, 1985, Contrib Nephrol, V46, P14
[5]   SOLUTE TRANSPORT CHARACTERISTICS IN HEMODIAFILTRATION [J].
CHANG, YL ;
LEE, CJ .
JOURNAL OF MEMBRANE SCIENCE, 1988, 39 (02) :99-111
[6]   EFFECT OF PLASMA-PROTEINS ON THE SIEVING SPECTRA OF HEMOFILTERS [J].
FELDHOFF, P ;
TURNHAM, T ;
KLEIN, E .
ARTIFICIAL ORGANS, 1984, 8 (02) :186-192
[7]  
GOSTOLI C, 1980, J MEMBRANE SCI, V6, P133, DOI 10.1016/S0376-7388(00)82156-0
[8]  
HOSOYA N, 1990, T AM SOC ART INT ORG, V36, P311
[9]   A ONE-DIMENSIONAL MODEL OF SIMULTANEOUS HEMODIALYSIS AND ULTRAFILTRATION WITH HIGHLY PERMEABLE MEMBRANES [J].
JAFFRIN, MY ;
GUPTA, BB ;
MALBRANCQ, JM .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1981, 103 (04) :261-266
[10]   SIMULTANEOUS CONVECTIVE AND DIFFUSIVE MASS TRANSFERS IN A HEMODIALYSER [J].
JAFFRIN, MY ;
DING, L ;
LAURENT, JM .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1990, 112 (02) :212-219