Exact and approximate algorithms for helical cone-beam CT

被引:35
作者
Kudo, H [1 ]
Rodet, T [1 ]
Noo, F [1 ]
Defrise, M [1 ]
机构
[1] Univ Tsukuba, Dept Comp Sci, Grad Sch Syst & Informat Engn, Tsukuba, Ibaraki, Japan
关键词
D O I
10.1088/0031-9155/49/13/011
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This paper concerns image reconstruction for helical x-ray transmission tomography (CT) with multi-row detectors. We introduce two approximate cone-beam (CB) filtered-backprojection (FBP) algorithms of the Feldkamp type, obtained by extending to three dimensions (3D) two recently proposed exact FBP algorithms for 2D fan-beam reconstruction. The new algorithms are similar to the standard Feldkamp-type FBP for helical CT. In particular, they can reconstruct each transaxial slice from data acquired along an arbitrary segment of helix, thereby efficiently exploiting the available data. In contrast to the standard Feldkamp-type algorithm, however, the redundancy weight is applied after filtering, allowing a more efficient numerical implementation. To partially alleviate the CB artefacts, which increase with increasing values of the helical pitch, a frequency-mixing method is proposed. This method reconstructs the high frequency components of the image using the longest possible segment of helix, whereas the low frequencies are reconstructed using a minimal, short-scan, segment of helix to minimize CB artefacts. The performance of the algorithms is illustrated using simulated data.
引用
收藏
页码:2913 / 2931
页数:19
相关论文
共 36 条
[1]   A quasiexact reconstruction algorithm for helical CT using a 3-Pi acquisition [J].
Bontus, C ;
Köhler, T ;
Proksa, R .
MEDICAL PHYSICS, 2003, 30 (09) :2493-2502
[2]  
DANIELSSON PE, 1997, P 1997 INT M FULL 3, P141
[3]   Rebinning-based algorithms for helical cone-beam CT [J].
Defrise, M ;
Noo, F ;
Kudo, H .
PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (11) :2911-2937
[4]  
DERISE M, 2003, INVERSE PROBL, V19, pS1
[5]   PRACTICAL CONE-BEAM ALGORITHM [J].
FELDKAMP, LA ;
DAVIS, LC ;
KRESS, JW .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1984, 1 (06) :612-619
[6]   Image reconstruction and image quality evaluation for a 16-slice CT scanner [J].
Flohr, T ;
Stierstorfer, K ;
Bruder, H ;
Simon, J ;
Polacin, A ;
Schaller, S .
MEDICAL PHYSICS, 2003, 30 (05) :832-845
[7]  
Hamaker C, 1980, ROCKY MOUNTAIN J MAT, V10, P253
[8]   Redundant data and exact helical cone-beam reconstruction [J].
Heuscher, D ;
Brown, K ;
Noo, F .
PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (11) :2219-2238
[9]  
HEUSCHER D, 1999, INT M FULL 3 DIM IM, P204
[10]   Advanced single-slice rebinning in cone-beam spiral CT [J].
Kachelriess, M ;
Schaller, S ;
Kalender, WA .
MEDICAL PHYSICS, 2000, 27 (04) :754-772