Magnetic resonance T1w/T2w ratio in the middle cerebellar peduncle might be a sensitive biomarker for multiple system atrophy

被引:8
作者
Sugiyama, Atsuhiko [1 ]
Yokota, Hajime [2 ]
Hirano, Shigeki [1 ]
Cooper, Graham [3 ,4 ,5 ,6 ,7 ,8 ,9 ,10 ]
Mukai, Hiroki [2 ]
Koide, Kyosuke [1 ]
Wang, Jiaqi [1 ]
Ito, Shoichi [1 ,11 ]
Finke, Carsten [8 ,12 ,13 ]
Brandt, Alexander U. [7 ,14 ]
Paul, Friedemann [3 ,4 ,5 ,6 ,7 ,8 ,12 ]
Kuwabara, Satoshi [1 ]
机构
[1] Chiba Univ, Dept Neurol, Grad Sch Med, Chuo Ku, 1-8-1 Inohana, Chiba 2608677, Japan
[2] Chiba Univ, Grad Sch Med, Dept Diagnost Radiol & Radiat Oncol, Chiba, Japan
[3] Humboldt Univ, Expt & Clin Res Ctr, Max Delbrueck Ctr Mol Med, Berlin, Germany
[4] Charite Univ Med Berlin, Berlin, Germany
[5] Free Univ Berlin, Humboldt Univ Berlin, Berlin, Germany
[6] Berlin Inst Hlth, Berlin, Germany
[7] Charite Univ Med Berlin, NeuroCure Clin Res Ctr, Berlin, Germany
[8] Einstein Ctr Neurosci, Berlin, Germany
[9] Charite Univ Med Berlin, Dept Expt Neurol, Berlin, Germany
[10] Charite Univ Med Berlin, Ctr Stroke Res, Berlin, Germany
[11] Chiba Univ, Grad Sch Med, Dept Med Educ, Chiba, Japan
[12] Charite Univ Med Berlin, Dept Neurol, Berlin, Germany
[13] Humboldt Univ, Berlin Sch Mind & Brain, Berlin, Germany
[14] Univ Calif Irvine, Dept Neurol, Irvine, CA 92717 USA
关键词
Magnetic resonance imaging; Cerebellar ataxia; Middle cerebellar peduncle; Multiple system atrophy; MYELIN CONTENT; DIAGNOSIS; MR; CRITERIA; PHENOTYPE; CORTEX; MSA;
D O I
10.1007/s00330-020-07521-1
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective We aimed to investigate the use of a myelin-sensitive MRI contrast, the standardized T1-weighted/T2-weighted (sT1w/T2w) ratio, for detecting early changes in the middle cerebellar peduncle (MCP) in cerebellar subtype multiple system atrophy (MSA-C) patients. Methods We included 28 MSA-C patients, including a subset of 17 MSA-C patients within 2 years of disease onset (early MSA-C), and 28 matched healthy controls. T1w and T2w scans were acquired using a 3-T MR system. The sT1w/T2w ratio in MCP was analyzed using SPM12 by utilizing a region-of-interest approach in normalized space. The diagnostic performance of the MCP sT1w/T2w ratio in discriminating MSA-C and the subgroup of early MSA-C from the matched controls was assessed. Correlation analyses were performed to evaluate the relationship between the MCP sT1w/T2w ratio and other clinical parameters including the International Cooperative Ataxia Scale (ICARS) score for quantifying cerebellar ataxia. Results Compared to controls, the sT1w/T2w ratio in the MCP was markedly lower in all (p < 0.001) MSA-C patients and 17 early (p < 0.001) MSA-C patients. The MCP sT1w/T2w ratio had high sensitivity (96%) and specificity (100%) to distinguish MSA-C from controls (area under the curve = 0.99), even for the early MSA-C group (area under the curve = 0.99; sensitivity = 94%, specificity = 100%). The MCP sT1w/T2w ratio correlated with the ICARS score in early MSA-C. Conclusions The sT1w/T2w ratio can detect MSA-C-related changes in the MCP, even in the early stages of the disorder, and could be a sensitive biomarker for MSA-C.
引用
收藏
页码:4277 / 4284
页数:8
相关论文
共 38 条
[1]   Test-Retest Reliability and Concurrent Validity of in Vivo Myelin Content Indices: Myelin Water Fraction and Calibrated T1w/T2w Image Ratio [J].
Arshad, Muzamil ;
Stanley, Jeffrey A. ;
Raz, Naftali .
HUMAN BRAIN MAPPING, 2017, 38 (04) :1780-1790
[2]  
Barkovich AJ, 2000, AM J NEURORADIOL, V21, P1099
[3]   Brain magnetic resonance imaging in multiple-system atrophy and Parkinson disease - A diagnostic algorithm [J].
Bhattacharya, K ;
Saadia, D ;
Eisenkraft, B ;
Yahr, M ;
Olanow, W ;
Drayer, B ;
Kaufmann, H .
ARCHIVES OF NEUROLOGY, 2002, 59 (05) :835-842
[4]   Progression of alpha-synuclein pathology in multiple system atrophy of the cerebellar type [J].
Brettschneider, J. ;
Irwin, D. J. ;
Boluda, S. ;
Byrne, M. D. ;
Fang, L. ;
Lee, E. B. ;
Robinson, J. L. ;
Suh, E. ;
Van Deerlin, V. M. ;
Toledo, J. B. ;
Grossman, M. ;
Hurtig, H. ;
Dengler, R. ;
Petri, S. ;
Lee, V. M. -Y. ;
Trojanowski, J. Q. .
NEUROPATHOLOGY AND APPLIED NEUROBIOLOGY, 2017, 43 (04) :315-329
[5]   Proposed Neuroimaging Criteria for the Diagnosis of Multiple System Atrophy [J].
Brooks, David J. ;
Seppi, Klaus .
MOVEMENT DISORDERS, 2009, 24 (07) :949-964
[6]   Clinical and magnetic resonance imaging characteristics of sporadic cerebellar ataxia [J].
Bürk, K ;
Bühring, U ;
Schulz, JB ;
Zühlke, C ;
Hellenbroich, Y ;
Dichgans, J .
ARCHIVES OF NEUROLOGY, 2005, 62 (06) :981-985
[7]   Standardization of T1w/T2w Ratio Improves Detection of Tissue Damage in Multiple Sclerosis [J].
Cooper, Graham ;
Finke, Carsten ;
Chien, Claudia ;
Brandt, Alexander U. ;
Asseyer, Susanna ;
Ruprecht, Klemens ;
Bellmann-Strobl, Judith ;
Paul, Friedemann ;
Scheel, Michael .
FRONTIERS IN NEUROLOGY, 2019, 10
[8]   Abnormalities of white and grey matter in early multiple system atrophy: comparison of parkinsonian and cerebellar variants [J].
Dash, Santosh Kumar ;
Stezin, Albert ;
Takalkar, Tejashree ;
George, Lija ;
Kamble, Nitish L. ;
Netravathi, M. ;
Yadav, Ravi ;
Kumar, Keshav J. ;
Ingalhalikar, Madhura ;
Saini, Jitender ;
Pal, Pramod Kumar .
EUROPEAN RADIOLOGY, 2019, 29 (02) :716-724
[9]   Magnetic resonance T1w/T2w ratio: A parsimonious marker for Parkinson disease [J].
Du, Guangwei ;
Lewis, Mechelle M. ;
Sica, Christopher ;
Kong, Lan ;
Huang, Xuemei .
ANNALS OF NEUROLOGY, 2019, 85 (01) :96-104
[10]   Estimation of the Youden index and its associated cutoff point [J].
Fluss, R ;
Faraggi, D ;
Reiser, B .
BIOMETRICAL JOURNAL, 2005, 47 (04) :458-472