Optimization and Evaluation of Reference Region Variable Flip Angle (RR-VFA) B1+ and T1 Mapping in the Prostate at 3T

被引:9
作者
Rangwala, Novena A. [1 ]
Dregely, Isabel [1 ]
Wu, Holden H. [1 ]
Sung, Kyunghyun [1 ]
机构
[1] Univ Calif Los Angeles, Dept Radiol Sci, Los Angeles, CA 90024 USA
关键词
CONTRAST-ENHANCED MRI; HIGH-RESOLUTION T-1; RADIOFREQUENCY FIELD; 3.0; T; RELAXATION-TIMES; STEADY-STATE; CANCER; BREAST; INHOMOGENEITY; ACQUISITION;
D O I
10.1002/jmri.25410
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To optimize and evaluate the reference region variable flip angle (RR-VFA) technique for simultaneous B-1(+) and T-1 mapping of the prostate at 3 Tesla (T). Materials and Methods: The fat region surrounding the prostate was first identified using a fractional fat segmentation constant (t(F)) and a signal fat-fraction threshold (r(F)), and the relative flip angle (FA) was characterized using an effective fat T-1 (T-1f) within the fat region. Optimal values of t(F), r(F), and T-1f were chosen by comparing relative FA maps using RR-VFA (A(RR-VFA)) with a reference relative FA maps (A(REF)) in the surrounding fat and evaluating interpolation errors within the prostate. The optimized RR-VFA was evaluated in volunteers at 3T on a single scanner (n = 10) and across three scanners (n = 4). Results: t(F), r(F) and T-1f were optimized as 0.5, 90%, and 320 ms, respectively. Prostate A(RR-VFA) showed differences of 30% among volunteers on one scanner, with no significant differences between A(RR-VFA) and A(REF) (P = 0.41). Prostate T-1 after B-1(+) correction was 1998113 ms with significantly (P = 0.004) lower standard deviation than T-1 before B-1(+) correction. The average coefficient of variation of prostate T-1 across multiple scanners decreased from 15% to 5% after B-1(+) correction. Conclusion: The optimized RR-VFA can simultaneously measure B(1)(+)and T-1 in the prostate without the need for an additional scan and improve T-1 consistency within and across MRI scanners at 3T.
引用
收藏
页码:751 / 760
页数:10
相关论文
共 50 条
  • [21] Analysis of the Precision of Variable Flip Angle T1 Mapping with Emphasis on the Noise Propagated from RF Transmit Field Maps
    Lee, Yoojin
    Callaghan, Martina F.
    Nagy, Zoltan
    [J]. FRONTIERS IN NEUROSCIENCE, 2017, 11
  • [22] Dual flip-angle IR-FLASH with spin history mapping for B1+corrected T1 mapping: Application to T1 cardiovascular magnetic resonance multitasking
    Serry, Fardad Michael
    Ma, Sen
    Mao, Xianglun
    Han, Fei
    Xie, Yibin
    Han, Hui
    Li, Debiao
    Christodoulou, Anthony G.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2021, 86 (06) : 3182 - 3191
  • [23] Fat Fraction Bias Correction Using T1 Estimates and Flip Angle Mapping
    Yang, Issac Y.
    Cui, Yifan
    Wiens, Curtis N.
    Wade, Trevor P.
    Friesen-Waldner, Lanette J.
    McKenzie, Charles A.
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2014, 39 (01) : 217 - 223
  • [24] Motion-robust cardiac B1+ mapping at 3T using interleaved bloch-siegert shifts
    Weingartner, Sebastian
    Zimmer, Fabian
    Metzger, Gregory J.
    Ugurbil, Kamil
    Van de Moortele, Pierre-Francois
    Akcakaya, Mehmet
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2017, 78 (02) : 670 - 677
  • [25] Variable Flip Angle T1 Mapping in the Human Brain with Reduced T2 Sensitivity Using Fast Radiofrequency-Spoiled Gradient Echo Imaging
    Heule, Rahel
    Ganter, Carl
    Bieri, Oliver
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2016, 75 (04) : 1413 - 1422
  • [26] Feasibility of 3D MRI fingerprinting for rapid knee cartilage T1, T2, and T1ρ mapping at 0.55T: Comparison with 3T
    De Moura, Hector L.
    Monga, Anmol
    Zhang, Xiaoxia
    Zibetti, Marcelo V. W.
    Keerthivasan, Mahesh B.
    Regatte, Ravinder R.
    [J]. NMR IN BIOMEDICINE, 2024, 37 (12)
  • [27] Rapid and Robust Variable Flip Angle T1 Mapping Using Interleaved Two-Dimensional Multislice Spoiled Gradient Echo Imaging
    Heule, Rahel
    Bieri, Oliver
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2017, 77 (04) : 1606 - 1611
  • [28] Effects of T2* on accuracy and precision of dynamic T1 measurements using the single reference variable flip angle method: a simulation study
    Malmberg, Michael A.
    Odeen, Henrik
    Parker, Dennis L.
    [J]. MEDICAL PHYSICS, 2022, 49 (04) : 2396 - 2412
  • [29] Brain Metabolites B1-Corrected Proton T1 Mapping in the Rhesus Macaque at 3 T
    Liu, Songtao
    Fleysher, Roman
    Fleysher, Lazar
    Joo, Chan-Gyu
    Ratai, Eva-Maria
    Gonzalez, R. Gilberto
    Gonen, Oded
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2010, 63 (04) : 865 - 871
  • [30] B1 Mapping for Bias-Correction in Quantitative T1 Imaging of the Brain at 3T Using Standard Pulse Sequences
    Boudreau, Mathieu
    Tardif, Christine L.
    Stikov, Nikola
    Sled, John G.
    Lee, Wayne
    Pike, G. Bruce
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2017, 46 (06) : 1673 - 1682