A simplified echocardiographic technique for detecting continuous-flow left ventricular assist device malfunction due to pump thrombosis

被引:30
作者
Estep, Jerry D. [1 ]
Vivo, Rey P. [1 ,2 ]
Cordero-Reyes, Andrea M. [1 ]
Bhimaraj, Arvind [1 ]
Trachtenberg, Barry H. [1 ]
Torre-Amione, Guillermo [1 ,3 ]
Chang, Su Min [1 ]
Elias, Barbara [1 ]
Bruckner, Brian A. [1 ]
Suarez, Erik E. [1 ]
Loebe, Matthias [1 ]
机构
[1] Houston Methodist DeBakey Heart & Vasc Ctr, Houston, TX USA
[2] Univ Calif Los Angeles, Ahmanson Cardiomyopathy Ctr, Mech & Circulatory Support & Heart Transplantat P, Los Angeles, CA USA
[3] Catedra Cardiol & Med Vasc Tecnol Monterrey, Monterrey, Nuevo Leon, Mexico
关键词
heart failure; left ventricular assist device; thrombosis; echocardiography; cardiomyopathy; AMERICAN-SOCIETY; INTERNATIONAL SOCIETY; EUROPEAN-ASSOCIATION; STANDARDS COMMITTEE; HEART-FAILURE; TASK-FORCE; RECOMMENDATIONS; GUIDELINES; DIAGNOSIS; QUANTIFICATION;
D O I
10.1016/j.healun.2014.01.865
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND: Malfunction of a continuous-flow left ventricular assist device (CF-LVAD) due to device thrombosis is a potentially life-threatening event that currently presents a diagnostic challenge. We aimed to propose a practical echocardiographic assessment to diagnose LVAD malfunction secondary to pump thrombosis. METHODS: Among 52 patients implanted with a CF-LVAD from a single center who underwent echocardiographic pump speed-change testing, 12 had suspected pump thrombosis as determined by clinical, laboratory, and/or device parameters. Comprehensive echocardiographic evaluation was performed at baseline pump speed and at each 1,000-rpm interval from the low setting of 8,000 rpm to the high setting of 11,000 rpm in 11 of these patients. RESULTS: Receiver operating characteristic curves and stepwise logistic regression analyses showed that the best diagnostic parameters included changes in the LV end-diastolic diameter (<0.6 cm), aortic valve opening time (<80 msec), and deceleration time of mitral inflow (<70 msec) from lowest to highest pump speed. One parameter was predictive of pump malfunction, with 100% sensitivity and 89% specificity, whereas 2 of 3 parameters increased the sensitivity to 100% and specificity to 95%. CONCLUSIONS: The 3 echocardiographic variables of measured changes in LV end-diastolic diameter, aortic valve opening time, and deceleration time of mitral inflow between the lowest (8,000 rpm) and highest pump speed settings (11,000 rpm) during echo-guided pump speed-change testing appear highly accurate in diagnosing device malfunction in the setting of pump thrombosis among patients supported with CF-LVAD. Further investigation is warranted to create and validate a prediction score. (C) 2014 International Society for Heart and Lung Transplantation. All rights reserved.
引用
收藏
页码:575 / 586
页数:12
相关论文
共 30 条
  • [1] Eptifibatide for the Treatment of HeartMate II Left Ventricular Assist Device Thrombosis
    Al-Quthami, Adeeb H.
    Jumean, Marwan
    Kociol, Robb
    Duc Thinh Pham
    Kiernan, Michael
    DeNofrio, David
    Kapur, Navin K.
    [J]. CIRCULATION-HEART FAILURE, 2012, 5 (04) : E68 - E70
  • [2] Thrombosis and failure of a Heart Mate II Device in the absence of alarms
    Bashir, Jamil
    Cheung, Anson
    Kaan, AnneMarie
    Kearns, Mark
    Ibey, Andrew
    Ignaszewski, Andrew
    [J]. JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2011, 30 (10) : 1197 - 1199
  • [3] Early thrombus in a HeartMate II left ventricular assist device: A potential cause of hemolysis and diagnostic dilemma
    Bhamidipati, Castigliano M.
    Ailawadi, Gorav
    Bergin, James
    Kern, John A.
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2010, 140 (01) : E7 - E8
  • [4] Chang SM, 2012, CIRCULATION, V126
  • [5] Imaging for Ventricular Function and Myocardial Recovery on Nonpulsatile Ventricular Assist Devices
    Estep, Jerry D.
    Chang, Su Min
    Bhimaraj, Arvind
    Torre-Amione, Guillermo
    Zoghbi, William A.
    Nagueh, Sherif F.
    [J]. CIRCULATION, 2012, 125 (18) : 2265 - 2277
  • [6] The Role of Echocardiography and Other Imaging Modalities in Patients With Left Ventricular Assist Devices
    Estep, Jerry D.
    Stainback, Raymond F.
    Little, Stephen H.
    Torre, Guillermo
    Zoghbi, William A.
    [J]. JACC-CARDIOVASCULAR IMAGING, 2010, 3 (10) : 1049 - 1064
  • [7] The 2013 International Society for Heart and Lung Transplantation Guidelines for mechanical circulatory support: Executive summary
    Feldman, David
    Pamboukian, Salpy V.
    Teuteberg, Jeffrey J.
    Birks, Emma
    Lietz, Katherine
    Moore, Stephanie A.
    Morgan, Jeffrey A.
    Arabia, Francisco
    Bauman, Mary E.
    Buchholz, Hoger W.
    Deng, Mario
    Dickstein, Marc L.
    El-Banayosy, Aly
    Elliot, Tonya
    Goldstein, Daniel. J.
    Grady, Kathleen L.
    Jones, Kylie
    Hryniewicz, Katarzyna
    John, Ranjit
    Kaan, Annemarie
    Kusne, Shimon
    Loebe, Matthias
    Massicotte, M. Patricia
    Moazami, Nader
    Mohacsi, Paul
    Mooney, Martha
    Nelson, Thomas
    Pagani, Francis
    Perry, William
    Potapov, Evgenij V.
    Rame, Eduardo
    Russell, Stuart D.
    Sorensen, Erik N.
    Sun, Benjamin
    Strueber, Martin
    Mangi, Abeel A.
    Petty, Michael G.
    Rogers, Joseph
    [J]. JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2013, 32 (02) : 157 - 187
  • [8] Algorithm for the diagnosis and management of suspected pump thrombus
    Goldstein, Daniel J.
    John, Ranjit
    Salerno, Christopher
    Silvestry, Scott
    Moazami, Nader
    Horstmanshof, Douglas
    Adamson, Robert
    Boyle, Andrew
    Zucker, Mark
    Rogers, Joseph
    Russell, Stuart
    Long, James
    Pagani, Francis
    Jorde, Ulrich
    [J]. JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2013, 32 (07) : 667 - 670
  • [9] Readmissions After Implantation of Axial Flow Left Ventricular Assist Device
    Hasin, Tal
    Marmor, Yariv
    Kremers, Walter
    Topilsky, Yan
    Severson, Cathy J.
    Schirger, John A.
    Boilson, Barry A.
    Clavell, Alfredo L.
    Rodeheffer, Richard J.
    Frantz, Robert P.
    Edwards, Brooks S.
    Pereira, Naveen L.
    Stulak, John M.
    Joyce, Lyle
    Daly, Richard
    Park, Soon J.
    Kushwaha, Sudhir S.
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2013, 61 (02) : 153 - 163
  • [10] 2009 Focused Update Incorporated Into the ACC/AHA 2005 Guidelines for the Diagnosis and Management of Heart Failure in Adults A Report of the American College of Cardiology Foundation/American Heart Association Task Force on Practice Guidelines
    Hunt, Sharon Ann
    Abraham, William T.
    Chin, Marshall H.
    Feldman, Arthur M.
    Francis, Gary S.
    Ganiats, Theodore G.
    Konstam, Marvin A.
    Mancini, Donna M.
    Michl, Keith
    Oates, John A.
    Rahko, Peter S.
    Silver, Marc A.
    Stevenson, Lynne Warner
    Yancy, Clyde W.
    Jessup, Mariell
    Casey, Donald E.
    [J]. CIRCULATION, 2009, 119 (14) : E391 - E479