Improving the Performance of a 1-MW Induction Machine by Optimally Shifting From a Three-Phase to a Six-Phase Machine Design by Rearranging the Coil Connections

被引:35
作者
Paredes, Jesus [1 ,2 ]
Prieto, Borja [1 ,2 ]
Satrustegui, Marco [1 ,2 ]
Elosegui, Ibon [1 ,2 ]
Gonzalez, Patxi [3 ]
机构
[1] CEIT, Transport & Energy Div, Donostia San Sebastian 20009, Guipuzcoa, Spain
[2] Univ Navarra, Sch Engn Sch, Donostia San Sebastian 20009, Guipuzcoa, Spain
[3] Obeki Innobe Res Ctr, Ibarra 20400, Spain
基金
瑞典研究理事会;
关键词
Fault tolerance; induction machine; multiphase systems; six-phase machine; stator winding configuration; winding optimization; PERMANENT-MAGNET MACHINES; POSTFAULT OPERATION; WINDING CONNECTION; TORQUE RIPPLES; 5-PHASE; MOTOR; SINGLE; TESTS;
D O I
10.1109/TIE.2020.2969099
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
It is well known that multiphase machines exhibit the better performance (efficiency, torque density, fault tolerance, etc.) than three-phase machines. From the manufacturing point of view, it is interesting to have the possibility of improving a machine design by just conducting minor changes in the production process. In this regard, six-phase machines emerge as the natural choice to improve a design without modifying the active parts. This article presents an optimal procedure to shift from a three-phase to a six-phase induction motor design by just rearranging the coil connections. By starting from a three-phase winding design, different six-phase winding arrangements are analyzed. A methodology to define all the possible six-phase winding arrangements is presented. Discard criteria based on balanced radial forces and impedances are defined. Afterward, selected winding candidates are compared in terms of analytical calculations and later on, based on finite element (FE) simulations for a 690 V, 1-MW induction machine design. Different possible configurations are evaluated in terms of stator Joule losses, torque ripple, power factor, and electromagnetic efficiency both under healthy and faulted inverter conditions. Finally, a six-phase machine prototype is tested in order to verify the improvement in machine characteristics, thus validating the proposed method.
引用
收藏
页码:1035 / 1045
页数:11
相关论文
共 52 条
[1]  
Abdel-Khalik A. S., 2016, P 22 INT C EL MACH, V52, P285
[2]   Application of Standard Three-Phase Stator Frames in Prime Phase Order Multiphase Machine Construction [J].
Abdel-Khalik, Ayman S. ;
Massoud, Ahmed M. ;
Ahmed, Shehab .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2019, 66 (04) :2506-2517
[3]   Effect of Stator Winding Connection of Five-Phase Induction Machines on Torque Ripples Under Open Line Condition [J].
Abdel-Khalik, Ayman S. ;
Ahmed, Shehab ;
Elserougi, Ahmed A. ;
Massoud, Ahmed M. .
IEEE-ASME TRANSACTIONS ON MECHATRONICS, 2015, 20 (02) :580-593
[4]   Postfault Operation of a Nine-Phase Six-Terminal Induction Machine Under Single Open-Line Fault [J].
Abdel-Khalik, Ayman Samy ;
Hamad, Mostafa S. ;
Massoud, Ahmed M. ;
Ahmed, Shehab .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2018, 65 (02) :1084-1096
[5]   Low Space Harmonics Cancelation in Double-Layer Fractional Slot Winding Using Dual Multiphase Winding [J].
Abdel-Khalik, Ayman Samy ;
Ahmed, Shehab ;
Massoud, Ahmed M. .
IEEE TRANSACTIONS ON MAGNETICS, 2015, 51 (05)
[6]  
Alberti L, 2012, IEEE ENER CONV, P166, DOI 10.1109/ECCE.2012.6342827
[7]   Experimental Tests of Dual Three-Phase Induction Motor Under Faulty Operating Condition [J].
Alberti, Luigi ;
Bianchi, Nicola .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2012, 59 (05) :2041-2048
[8]  
[Anonymous], 2011, Electrical Power Systems and Computers, P793
[9]  
ANSYS, ANSYS MAXWELL 2019 R
[10]   Induction motor performance as a function of phase number [J].
Apsley, J. M. ;
Williamson, S. ;
Smith, A. C. ;
Barnes, M. .
IEE PROCEEDINGS-ELECTRIC POWER APPLICATIONS, 2006, 153 (06) :898-904