摘要
The responses of readings by the TL dosimetry system MR200 TL developed in-house and used at JSI and the TOLEDO TL system used at RBI are compared. Ten measurements at different doses ranging from 0.01 mSv to 5 Sv were carried out. A set of 36 dosemeters with three pellets of CaF2:Mn were irradiated in radiation fields of Cs-137 and Co-60. Analysis of the measured results shows that at doses below 0.1 Sv, readers' outputs do not differ > 5% from each other. At doses > 1 Sv, the results obtained by the MR200 reader must be corrected with a known factor. Finally, the reproducibility of the results from the MR200 was tested.
引用
收藏
页码:300 / 305
页数:6
相关论文
共 50 条
  • [1] UV DOSIMETRY BY INTRINSIC TL OF CAF2 - DY
    BASSI, P
    BUSUOLI, G
    HEALTH PHYSICS, 1976, 31 (02): : 179 - 181
  • [2] USE OF INTRINSIC TL OF CAF2=DY FOR UV DOSIMETRY
    BASSI, P
    BUSUOLI, G
    RIMONDI, O
    HEALTH PHYSICS, 1977, 33 (03): : 274 - 275
  • [3] Dosimetry in mixed gamma-neutron radiation fields and energy compensation filters for CaF2:Tm TL detectors
    Becker, F.
    Nagels, S.
    Burgkhardt, B.
    Boettger, R.
    Aguilar, A. Lizon
    Hampel, G.
    Wortmann, B.
    RADIATION MEASUREMENTS, 2008, 43 (2-6) : 921 - 924
  • [4] Effect of heating rate on the responses of CaF2:Cu, CaF2:Tm, CaF2:Dy and CaF2:Mn
    Pradhan, AS
    SOLID STATE DOSIMETRY, PTS 1 AND 2, PROCEEDINGS, 2002, : 289 - 292
  • [5] Effect of heating rate on the responses of CaF2:Cu, CaF2:Tm, CaF2:Dy and CaF2:Mn
    Pradhan, AS
    RADIATION PROTECTION DOSIMETRY, 2002, 100 (1-4) : 289 - 292
  • [6] Evaluation of TL and OSL responses of CaF2:Tm for electron beam processing dosimetry
    Asfora, Viviane K.
    Antonio, Patricia L.
    Goncalves, Josemary A. C.
    Bueno, Carmen C.
    Barros, Vinicius S. M. de
    Oliveira, Charles N. P.
    Caldas, Linda V. E.
    Khoury, Helen J.
    RADIATION MEASUREMENTS, 2021, 140
  • [7] Study on TL and OSL characteristics of indigenously developed CaF2:Mn phosphor
    Bakshi, A. K.
    Dhabekar, Bhushan
    Rawat, N. S.
    Singh, S. G.
    Joshi, V. J.
    Kumar, Vijay
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2009, 267 (03): : 548 - 553
  • [8] NEUTRON DOSIMETRY WITH THERMOLUMINESCENT NATURAL CAF2
    WATANABE, S
    MUCCILLO, R
    HEALTH PHYSICS, 1970, 19 (02): : 330 - +
  • [9] Synthesis Of Optically Transparent Ceramic Of CaF2 Doped With Mn And Ce For Thermoluminescent Dosimetry
    Sen, Shashwati
    Singh, S. G.
    Patra, G. D.
    Shinde, S.
    Bhattacharya, S.
    Gadkari, S. C.
    SOLID STATE PHYSICS, PTS 1 AND 2, 2012, 1447 : 279 - 280
  • [10] MN2+ ENDOR IN CAF2
    ZARIPOV, MM
    KAIBIYAINEN, VK
    MEIKLYAR, VP
    FALIN, ML
    FIZIKA TVERDOGO TELA, 1975, 17 (06): : 1691 - 1695