Charged particle detectors made of single-crystal diamond

被引:6
作者
Berdermann, E
Ciobanu, M
Connell, SH
da Costa, AMOD
Fernandez-Hernando, L
Oh, A
Sellschop, JPF
机构
[1] GSI, D-64291 Darmstadt, Germany
[2] Univ Witwatersrand, Schonland Res Inst Nucl Sci, Johannesburg, South Africa
[3] CERN, European Org Nucl Res, CH-1211 Geneva 23, Switzerland
来源
PHYSICA STATUS SOLIDI A-APPLIED RESEARCH | 2004年 / 201卷 / 11期
关键词
D O I
10.1002/pssa.200405170
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Very first test results obtained from an intrinsic single crystal CVD diamond detector are described and compared to those measured with polycrystalline CVD-diamond and HPHT Ib diamond sensors. The data are discussed in the context of the requirements of intermediate and high energy heavy-ion physics experiments. It is shown how the crystal structure and the chemical purity of diamond material affect the detector properties as well as vice versa how the detector response to impinging charged particles can be used to study the homogeneity of the mass density and the electrical properties of diamond. (C) 2004 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.