Preference selection index approach for optimization of V down perforated baffled roughened rectangular channel

被引:33
作者
Chamoli, Sunil [1 ]
机构
[1] DIT Univ, Dept Mech Engn, Dehra Dun 248001, Uttar Pradesh, India
关键词
Nusselt number; Friction factor; Preference selection index; Ranking; SOLAR AIR HEATER; PERFORMANCE EVALUATION; FUZZY AHP; TOPSIS; RANKING; DESIGN; MODEL; DUCT;
D O I
10.1016/j.energy.2015.09.125
中图分类号
O414.1 [热力学];
学科分类号
摘要
The research work analyzed the impact of insertion of the V down perforated baffles in the performance of the channel flow. The test apparatus is created, and all experimentation completed in the test rig and the information gathered for Nusselt number and friction factor for distinctive arrangement of roughness parameters. The test results demonstrate the critical improvement in both the Nusselt number and friction factor of the roughened channel over the smooth conduit. The open area ratio has a significant effect on the performance parameters, and it was found that there is a significant decrement in the pressure drop with an increase in the open area ratio. Preference selection method implied on performance prediction of roughened channel with a distinctive arrangement of roughness parameters, configurations using different PDCs including Nusselt number ratio, friction factor ratio, thermo hydraulic performance factor, thermal efficiency, effective efficiency and exergetic efficiency, respectively. The results of PSI (Preference selection index) show that the optimal formulation among all the configurations is with an open area ratio (beta): 12%, relative roughness pitch (P/e): 2 and relative roughness height (e/H): 0.4. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1418 / 1425
页数:8
相关论文
共 26 条