Derivation of isoeffect dose rate for low-dose-rate brachytherapy and external beam irradiation

被引:2
|
作者
Giap, HB [1 ]
Massullo, V [1 ]
机构
[1] Scripps Clin & Res Fdn, La Jolla, CA 92037 USA
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 1999年 / 45卷 / 05期
关键词
linear-quadratic model; biological equivalent dose; dose rate effect;
D O I
10.1016/S0360-3016(99)00331-4
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: The combination of external beam irradiation and brachytherapy has been used effectively in the management of many malignancies. Brachytherapy dose is typically prescribed to an isodose rate line, from which the implant duration is derived. In this study, the linear-quadratic model is used to derive the brachytherapy dose rate at which biological effectiveness is equivalent to that of external beam irradiation. Methods and Materials: Relative effectiveness per unit dose (RE) for brachytherapy was based on Dale's formalism, Isoeffect dose rate, defined as the brachytherapy dose rate at which the biological effectiveness is equivalent to that of external beam irradiation, was derived, Results: The functional dependencies of brachytherapy RE on dose rate, alpha/beta ratio, and implant duration were investigated. The isoeffect dose rate depends only on the dose per fraction, sublethal damage repair (SLDR) constant, and the implant duration. The isoeffect dose rate does not depend on alpha/beta ratio. For sufficiently long implant duration >10-15 hours, the value for isoeffect dose rate approaches a constant value around 40 to 50 cGy/hr. Conclusion: The isoeffect dose rate may be useful in treatment planning and optimization for low-dose-rate (LDR) brachytherapy, especially when brachytherapy is used in combination with external beam irradiation. (C) 1999 Elsevier Science Inc.
引用
收藏
页码:1355 / 1358
页数:4
相关论文
共 50 条
  • [1] Low-dose-rate brachytherapy is superior to high-dose-rate brachytherapy for bladder cancer
    Pos, FJ
    Horenblas, S
    Lebesque, J
    Moonen, L
    Schneider, C
    Sminia, P
    Bartelink, H
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 59 (03): : 696 - 705
  • [2] Compensation for changes in dose-rate in radical low-dose-rate brachytherapy: a radiobiological analysis of a randomised clinical trial
    Roberts, SA
    Hendry, JH
    Swindell, R
    Wilkinson, JM
    Hunter, RD
    RADIOTHERAPY AND ONCOLOGY, 2004, 70 (01) : 63 - 74
  • [3] Dose-rate effects in external beam radiotherapy redux
    Ling, C. Clifton
    Gerweck, Leo E.
    Zaider, Marco
    Yorke, Ellen
    RADIOTHERAPY AND ONCOLOGY, 2010, 95 (03) : 261 - 268
  • [4] Radiobiological equivalent of low/high dose rate brachytherapy and evaluation of tumor and normal responses to the dose
    Manimaran S.
    Radiation Medicine, 2007, 25 (5): : 229 - 235
  • [5] CONDITIONS FOR THE EQUIVALENCE OF CONTINUOUS TO PULSED LOW-DOSE RATE BRACHYTHERAPY
    BRENNER, DJ
    HALL, EJ
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1991, 20 (01): : 181 - 190
  • [6] Biological equivalence of low dose rate to multifractionated high dose rate irradiations: Investigations in mouse lip mucosa
    Stuben, G
    vanderKogel, AJ
    vanderSchueren, E
    RADIOTHERAPY AND ONCOLOGY, 1997, 42 (02) : 189 - 196
  • [7] PULSED BRACHYTHERAPY - THE CONDITIONS FOR NO SIGNIFICANT LOSS OF THERAPEUTIC RATIO COMPARED WITH TRADITIONAL LOW-DOSE RATE BRACHYTHERAPY
    FOWLER, J
    MOUNT, M
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1992, 23 (03): : 661 - 669
  • [8] Dose rate effects of gamma irradiation on silicone foam
    Liu, Bo
    Huang, Wei
    Ao, Yin-Yong
    Wang, Pu-Cheng
    An, You
    Chen, Hong-Bing
    POLYMER DEGRADATION AND STABILITY, 2018, 147 : 97 - 102
  • [9] Cellular responses and gene expression profiles of colonic Lgr5+ stem cells after low-dose/low-dose-rate radiation exposure
    Otsuka, Kensuke
    Suzuki, Keiji
    Fujimichi, Yuki
    Tomita, Masanori
    Iwasaki, Toshiyasu
    JOURNAL OF RADIATION RESEARCH, 2018, 59 : ii18 - ii22
  • [10] Pulsed brachytherapy: A formalism to account for the variation in dose rate of the stepping source
    Narayana, V
    Orton, CG
    MEDICAL PHYSICS, 1999, 26 (02) : 161 - 165