Study of avalanche photodiodes for soft X-ray detection below 20 keV

被引:32
作者
Yatsu, Y. [1 ]
Kuramoto, Y.
Kataoka, J.
Kotoku, J.
Saito, T.
Ikagawa, T.
Sato, R.
Kawai, N.
Kishimoto, S.
Mori, K.
Kamae, T.
Ishikawa, Y.
Kawabata, N.
机构
[1] Tokyo Inst Technol, Tokyo 152, Japan
[2] Inst Mat Struct Sci, Photon Factory, Tsukuba, Ibaraki, Japan
[3] Clear Pulse Co, Tokyo, Japan
[4] Stanford Linear Accelerator Ctr, Menlo Pk, CA USA
[5] Hamamatsu Photon KK, Shizuoka, Japan
关键词
avalanche photodiode; X-ray detector;
D O I
10.1016/j.nima.2006.03.035
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The performance of the large area reach-through avalanche photodiode (APD), manufactured by Hamamatsu Photonics, K.K. as a high resolution X-ray detector is presented. The mentioned APD has an area of 3 mm 0, a fast time response for signal carrier collection and its thick depletion layer of 130 pm shows a potential to be used as an effective X-ray absorber below 20 keV. Having a capacitance of similar to 10 pF and a low dark current of 5 nA for a gain of 15, at room temperature, this APD had demonstrated one of the best energy resolutions within this kind of devices: 6.4% (FWHM) for 5.9 keV photons with a minimum detectable energy of 0.3 keV, measured at -20 degrees C. The experiments for the timing property were made in a synchrotron beam facility using an 8 keV X-ray beam; the reached count rate was above 108 counts/s, corresponding to a very short dead time of 4.5 ns/pulse. In order to test the radiation hardness of the APD, the device was irradiated at a Ring Cyclotron Facility with a 53.5 MeV proton beam. The total dose was of 11.3 krad and no fatal damage was found in the APD, although the dark current of the APD had shown an increase of one order of magnitude. Finally, the obtained results allow us to affirm that the reach-through APD has the potential to become an excellent X-ray detector, especially in the space mission application. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:134 / 143
页数:10
相关论文
共 30 条
  • [11] Application of large-area avalanche photodiodes to energy-dispersive x-ray fluorescence analysis
    Fernandes, LMP
    Lopes, JAM
    dos Santos, JMF
    Conde, CAN
    [J]. X-RAY SPECTROMETRY, 2001, 30 (03) : 164 - 169
  • [12] Study of large area Hamamatsu avalanche photodiode in a γ-ray scintillation detector
    Ikagawa, T
    Kataoka, J
    Yatsu, Y
    Saita, T
    Kuramoto, Y
    Kawai, N
    Kokubun, M
    Kamae, T
    Ishikawa, Y
    Kawabata, N
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 538 (1-3) : 640 - 650
  • [13] Performance of large-area avalanche photodiode for low-energy X-rays and γ-rays scintillation detection
    Ikagawa, T
    Kataoka, J
    Yatsu, Y
    Kawai, N
    Mori, K
    Kamae, T
    Tajima, H
    Mizuno, T
    Fukazawa, Y
    Ishikawa, Y
    Kawabata, N
    Inutsuka, T
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 515 (03) : 671 - 679
  • [14] Recent progress of avalanche photodiodes in high-resoution X-rays and γ-rays detection
    Kataoka, J
    Saito, T
    Kuramoto, Y
    Ikagawa, T
    Yatsu, Y
    Kotoku, J
    Arimoto, M
    Kawai, N
    Ishikawa, Y
    Kawabata, N
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 541 (1-2) : 398 - 404
  • [15] A fast detector using stacked avalanche photodiodes for x-ray diffraction experiments with synchrotron radiation
    Kishimoto, S
    Ishizawa, N
    Vaalsta, TP
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1998, 69 (02) : 384 - 391
  • [16] A cooled avalanche photodiode detector for X-ray magnetic diffraction experiments
    Kishimoto, S
    Adachi, H
    Ito, M
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 467 : 1171 - 1174
  • [17] Behavior of a fast counting system with an avalanche photodiode detector for synchrotron X-rays
    Kishimoto, S
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 397 (2-3) : 343 - 353
  • [18] KNOLL GF, 2000, RAD DETECTION MEASUR, V14
  • [19] Planar LAAPDs:: temperature dependence, performance, and application in low-energy X-ray spectroscopy
    Ludhova, L
    Amaro, FD
    Antognini, A
    Biraben, F
    Cardoso, JMR
    Conde, CAN
    Covita, DS
    Dax, A
    Dhawan, S
    Fernandes, LMP
    Hänsch, TW
    Hughes, VW
    Huot, O
    Indelicato, P
    Julien, L
    Knowles, PE
    Kottmann, F
    Lopes, JAM
    Liu, YW
    Monteiro, CMB
    Mulhauser, F
    Nez, F
    Pohl, R
    Rabinowitz, P
    dos Santos, JMF
    Schaller, LA
    Taqqu, D
    Veloso, JFCA
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 540 (01) : 169 - 179
  • [20] MATSUMOTO C, 1998, IEEE T NUCL SCI NS, V45, P3