Determination of compost respiration rates using pressure sensors

被引:0
作者
Sadaka, Samy S. [1 ]
Richard, Tom L.
Loecke, Terrance D.
Liebman, Matt
机构
[1] Iowa State Univ, Ctr Sustainable Environm Technol, Ames, IA 50011 USA
[2] Penn State Univ, Dept Agr & Biol Engn, University Pk, PA 16802 USA
[3] Michigan State Univ, Kellogg Biol Stn, Hickory Corners, MI 49060 USA
[4] Iowa State Univ, Agron Dept, Ames, IA USA
关键词
D O I
暂无
中图分类号
Q14 [生态学(生物生态学)];
学科分类号
071012 ; 0713 ;
摘要
Compost stability is one of the most important criteria used to evaluate compost quality. Several of the most popular methods to quantify stability are based on measurements of aerobic respiration of oxygen to carbon dioxide. This study compared two closed-vessel respiration techniques. In both methods, the evolved CO2 was absorbed by sodium hydroxide (NaOH), leading to a pressure drop in the container. The conventional technique measures absorbed CO2 by titrating the NaOH trap, limiting measurement frequency by the need to manually remove and replace the trap. The pressure sensor method (PSM) uses a datalogger to record pressure differences in the vessel, allowing several observations each hour. Samples of bedded swine manure compost (n=125) were analyzed using both the PSM and the titration method (TM) during 48 h incubation at 30 degrees C. Each compost sample was also analyzed for total solids, volatile solids (VS), pH and electrical conductivity. Respiration results obtained using the PSM were compared with those obtained using the TM, with each method run on split compost samples under the same environmental conditions. Respiration rates measured by PSM and TM were highly correlated (R-2 = 0.92). Respiration rates ranged from 3.64 to 10.77 mg CO2-C gVS(-1) d(-1), varying with feedstock and the extent of prior composting. Decreases in volatile solids and/or increases in composting time resulted in decreases in the respiration rate, but the effect of pH and electrical conductivity was not clear. For the PSM, detailed time series data also allowed semi continuous observation of important changes in the respiration rate throughout the course of incubation. PSM is a sensitive and reliable method to quantify compost respiration and stability.
引用
收藏
页码:124 / 131
页数:8
相关论文
共 50 条
[31]   Integration of MEMS Inertial and Pressure Sensors for Vertical Trajectory Determination [J].
Zihajehzadeh, Shaghayegh ;
Lee, Tien Jung ;
Lee, Jung Keun ;
Hoskinson, Reynald ;
Park, Edward J. .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2015, 64 (03) :804-814
[32]   SIMPLE POTENTIOMETRIC METHOD FOR THE RAPID-DETERMINATION OF RESPIRATION RATES OF SMALL AQUATIC ORGANISMS [J].
LAUGHLIN, RB ;
WOFFORD, HW ;
NEFF, JM .
AQUACULTURE, 1979, 16 (01) :77-82
[33]   DETERMINATION OF AERATION CAPACITY OF FERMENTERS WITH FAST RESPONDING OXYGEN PROBE AT HIGH RESPIRATION RATES [J].
LINEK, V .
COLLECTION OF CZECHOSLOVAK CHEMICAL COMMUNICATIONS, 1974, 39 (04) :1020-1024
[34]   REDUCTION OF MARINE SEDIMENT OXYGEN-UPTAKE - PRETREATMENT FOR THE DETERMINATION OF INFAUNAL RESPIRATION RATES [J].
GOLDE, HM ;
CROSBY, MP ;
LOVELL, CR ;
STANCYK, SE .
MARINE ECOLOGY PROGRESS SERIES, 1994, 111 (1-2) :203-207
[35]   Determination and quantification of microplastics in compost [J].
Iswahyudi, Iswahyudi ;
Widodo, Wahyu ;
Warkoyo, Warkoyo ;
Sutanto, Adi ;
Garfansa, Marchel Putra ;
Septia, Erfan Dani .
ENVIRONMENTAL QUALITY MANAGEMENT, 2024, 34 (01)
[36]   Fatigue Estimation Using Foot Pressure Sensors [J].
Tanaka, Isamu ;
Terada, Shuhei ;
Tsuchiya, Ryuichi ;
Hanawa, Dai ;
Oguchi, Kimio .
2013 36TH INTERNATIONAL CONFERENCE ON TELECOMMUNICATIONS AND SIGNAL PROCESSING (TSP), 2013, :600-602
[37]   A sensing chair using pressure distribution sensors [J].
Tan, HZ ;
Slivovsky, LA ;
Pentland, A .
IEEE-ASME TRANSACTIONS ON MECHATRONICS, 2001, 6 (03) :261-268
[38]   PRESSURE SENSORS DEVELOPED USING AUXETIC STRUCTURES [J].
Dang, Brandon ;
Lee, Dongchan ;
Wang, Huaxia ;
Yang, Chulho .
PROCEEDINGS OF ASME 2023 INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, IMECE2023, VOL 4, 2023,
[39]   Dynamic Pressure Calibration of Pressure Sensors Using Liquid Step Pressure Generator [J].
Wang, Shenghung ;
Han, Leelong ;
Tsung, Tsing Tshih .
MEASUREMENT TECHNOLOGY AND INTELLIGENT INSTRUMENTS IX, 2010, 437 :8-12
[40]   Blockage Diagnosis of Microreactors by Using Pressure Sensors [J].
Yamamoto, Risa ;
Noda, Masaru ;
Nishitani, Hirokazu .
KAGAKU KOGAKU RONBUNSHU, 2009, 35 (01) :170-176