Determination of compost respiration rates using pressure sensors

被引:0
作者
Sadaka, Samy S. [1 ]
Richard, Tom L.
Loecke, Terrance D.
Liebman, Matt
机构
[1] Iowa State Univ, Ctr Sustainable Environm Technol, Ames, IA 50011 USA
[2] Penn State Univ, Dept Agr & Biol Engn, University Pk, PA 16802 USA
[3] Michigan State Univ, Kellogg Biol Stn, Hickory Corners, MI 49060 USA
[4] Iowa State Univ, Agron Dept, Ames, IA USA
关键词
D O I
暂无
中图分类号
Q14 [生态学(生物生态学)];
学科分类号
071012 ; 0713 ;
摘要
Compost stability is one of the most important criteria used to evaluate compost quality. Several of the most popular methods to quantify stability are based on measurements of aerobic respiration of oxygen to carbon dioxide. This study compared two closed-vessel respiration techniques. In both methods, the evolved CO2 was absorbed by sodium hydroxide (NaOH), leading to a pressure drop in the container. The conventional technique measures absorbed CO2 by titrating the NaOH trap, limiting measurement frequency by the need to manually remove and replace the trap. The pressure sensor method (PSM) uses a datalogger to record pressure differences in the vessel, allowing several observations each hour. Samples of bedded swine manure compost (n=125) were analyzed using both the PSM and the titration method (TM) during 48 h incubation at 30 degrees C. Each compost sample was also analyzed for total solids, volatile solids (VS), pH and electrical conductivity. Respiration results obtained using the PSM were compared with those obtained using the TM, with each method run on split compost samples under the same environmental conditions. Respiration rates measured by PSM and TM were highly correlated (R-2 = 0.92). Respiration rates ranged from 3.64 to 10.77 mg CO2-C gVS(-1) d(-1), varying with feedstock and the extent of prior composting. Decreases in volatile solids and/or increases in composting time resulted in decreases in the respiration rate, but the effect of pH and electrical conductivity was not clear. For the PSM, detailed time series data also allowed semi continuous observation of important changes in the respiration rate throughout the course of incubation. PSM is a sensitive and reliable method to quantify compost respiration and stability.
引用
收藏
页码:124 / 131
页数:8
相关论文
共 50 条
  • [21] Determination of compost pH
    Liang, Y
    Leonard, JJ
    Feddes, JJR
    McGill, WB
    PROCEEDINGS OF THE INTERNATIONAL COMPOSTING SYMPOSIUM (ICS'99), VOLS 1 AND 2, 2000, : 304 - 321
  • [22] Advantages of using ceramics for pressure sensors
    Wesstrom, O
    Richardson, S
    SICON/01: ISA/IEEE SENSORS FOR INDUSTRY CONFERENCE, PROCEEDINGS, 2001, : 197 - 202
  • [23] DETERMINATION OF ATP FROM COMPOST USING THE FIREFLY BIOLUMINESCENCE TECHNIQUE
    LEHTOKARI, M
    NIKKOLA, P
    PAATERO, J
    EUROPEAN JOURNAL OF APPLIED MICROBIOLOGY AND BIOTECHNOLOGY, 1983, 17 (03): : 187 - 190
  • [24] Application of compost in spruce forests: effects on soil respiration, basal respiration and microbial biomass
    Borken, W
    Muhs, A
    Beese, F
    FOREST ECOLOGY AND MANAGEMENT, 2002, 159 (1-2) : 49 - 58
  • [25] Highly Sensitive Cone-structured Porous Pressure Sensors for Respiration Monitoring Applications
    Panahi, M.
    Masihi, S.
    Hanson, A. J.
    Maddipatla, D.
    Zhang, X.
    Palaniappan, V
    Narakathu, B. B.
    Bazuin, B. J.
    Atashbar, M. Z.
    2021 IEEE SENSORS, 2021,
  • [26] RESPIRATION AS INFLUENCED BY UREA HERBICIDES IN SOIL AMENDED WITH COMPOST
    CHOPRA, P
    MAGU, SP
    INTERNATIONAL JOURNAL OF TROPICAL AGRICULTURE, 1986, 4 (02): : 137 - 142
  • [27] Advances in wearable respiration sensors
    Shen, Sophia
    Zhou, Qian
    Chen, Guorui
    Fang, Yunsheng
    Kurilova, Oliver
    Liu, Zeyang
    Li, Song
    Chen, Jun
    MATERIALS TODAY, 2024, 72 : 140 - 162
  • [28] MONITORING RESPIRATION WITH ACCELERATION SENSORS
    Bratek, Piotr
    Dziurdzia, Piotr
    Brzozowski, Ireneusz
    Gelmuda, Wojciech
    Ostrowski, Jacek
    Kos, Andrzej
    ELECTRONICS WORLD, 2016, 122 (1962): : 30 - 34
  • [29] Development of Respiration Measurement Methods Using Wearable Gyroscope and Acceleration Sensors
    Ikarashi, Akira
    SENSORS AND MATERIALS, 2025, 37 (02) : 643 - 648
  • [30] Determination of regularities that influence the acoustic pressure and accuracy of inertial sensors
    Korobiichuk, Igor
    Mel'nick, Viktorij
    Shybetskyi, Vladyslav
    Nowicki, Michal
    Rzeplinska-Rykala, Katarzyna
    ULTRASONICS, 2024, 136