Pixel Bleeding Correction in Laser Scanning Luminescence Imaging Demonstrated Using Optically Stimulated Luminescence

被引:13
|
作者
Yukihara, Eduardo G. [1 ]
Ahmed, Md Foiez [1 ]
机构
[1] Oklahoma State Univ, Dept Phys, Stillwater, OK 74078 USA
关键词
Dosimetry; fluorescence; image reconstruction; optically stimulated luminescence; pixel bleeding; radiation imaging; reconstruction algorithms; COMPUTED RADIOGRAPHY; RADIATION-THERAPY; F-CENTER; DOSIMETRY; AL2O3; PERFORMANCE; KCLEU2+; SYSTEMS;
D O I
10.1109/TMI.2015.2442755
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
This paper describes and investigates the performance of an algorithm to correct for "pixel bleeding" caused by slow luminescence centers in laser scanning imaging (e.g., X-ray imaging using photostimulable phosphors and 2D dosimetry using optically stimulated luminescence). The algorithm is based on a deconvolution procedure that takes into account the lifetime of the slow luminescence center and is further constrained by the detection of fast and slow luminescence centers and combining rows scanned in opposite directions. The algorithm was tested using simulated data and demonstrated experimentally by applying it to image reconstruction of two types of Al2O3 X-ray detector films (Al2O3:C and Al2O3:C, Mg), whose use in 2D dosimetry in conjunction with laser-scanning readout has so far been prevented by slow luminescence centers (F-centers, 35 ms lifetime). We show that the algorithm allows the readout of Al2O3 film detectors 300-500 times faster than generally allowed considering the lifetime of the main luminescence centers. By relaxing the stringent requirements on the detector's luminescence lifetime, the algorithm opens the possibility of using new materials in 2D dosimetry as well as other laser scanning applications, such as X-ray imaging using storage phosphors and scanning confocal microscopy, although the effect of the noise introduced must be investigated for each specific application.
引用
收藏
页码:2506 / 2517
页数:12
相关论文
共 50 条
  • [1] Optically stimulated luminescence dosimetry
    McKeever, SWS
    ENVIRONMENTAL MONITORING AND REMEDIATION TECHNOLOGIES, 1999, 3534 : 531 - 541
  • [2] Optically stimulated luminescence of alexandrite
    Nunes M.C.S.
    Trindade N.M.
    Yoshimura E.M.
    Chithambo M.L.
    Optical Materials: X, 2024, 22
  • [3] A methodology for on-board CBCT imaging dose using optically stimulated luminescence detectors
    Mail, Noor
    Yusuf, Muhammad
    Alothmany, Nazeeh
    Kinsara, A. Abdulrahman
    Abdulkhaliq, Fahad
    Ghamdi, Suliman M.
    Saoudi, Abdelhamid
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2016, 17 (05): : 482 - 499
  • [4] Optically stimulated luminescence of cowrie shells
    Ogundare, F. O.
    Chithambo, M. L.
    Akintunde, B. O.
    APPLIED RADIATION AND ISOTOPES, 2021, 167
  • [5] Beryllium oxide as optically stimulated luminescence dosimeter
    Sommer, M.
    Jahn, A.
    Henniger, J.
    RADIATION MEASUREMENTS, 2008, 43 (2-6) : 353 - 356
  • [6] BeO optically stimulated luminescence dosimetry using automated research readers
    Yukihara, E. G.
    Andrade, A. B.
    Eller, S.
    RADIATION MEASUREMENTS, 2016, 94 : 27 - 34
  • [7] Luminescence properties of BeO optically stimulated luminescence (OSL) detectors
    Yukihara, Eduardo G.
    RADIATION MEASUREMENTS, 2011, 46 (6-7) : 580 - 587
  • [8] Optically stimulated luminescence of Durolon polycarbonate
    Silva, A. O.
    Kunzel, R.
    Yoshimura, E. M.
    Pires, K. C. C.
    Trindade, N. M.
    JOURNAL OF LUMINESCENCE, 2024, 271
  • [9] Peculiarities of optically stimulated luminescence in halite
    Biernacka, M.
    Majgier, R.
    Maternicki, K.
    Liang, M.
    Mandowski, A.
    RADIATION MEASUREMENTS, 2016, 90 : 247 - 251
  • [10] On some fundamental features of optically stimulated luminescence measurements
    Chruscinska, A.
    RADIATION MEASUREMENTS, 2010, 45 (09) : 991 - 999