An Integrated Lumped Parameter-CFD approach for off-design ejector performance evaluation

被引:91
作者
Besagni, Giorgio [1 ]
Mereu, Riccardo [1 ]
Chiesa, Paolo [1 ]
Inzoli, Fabio [1 ]
机构
[1] Politecn Milan, Dept Energy, I-20156 Milan, Italy
关键词
Ejector modeling; Ejector efficiencies; Convergent nozzle; Computational Fluid Dynamics; Turbulence models; Modeling; COMPUTATIONAL FLUID-DYNAMICS; THERMO-COMPRESSOR DESIGN; JET REFRIGERATION SYSTEM; NUMERICAL ASSESSMENT; TURBULENCE MODELS; CONSTANT AREA; FLOW; CYCLE; OPTIMIZATION; VALIDATION;
D O I
10.1016/j.enconman.2015.08.029
中图分类号
O414.1 [热力学];
学科分类号
摘要
This paper presents an Integrated Lumped Parameter Model-Computational Fluid-Dynamics approach for off-design ejector performance evaluation. The purpose of this approach is to evaluate the entrainment ratio, for a fixed geometry, in both on-design and off-design operating conditions. The proposed model is based on a Lumped Parameter Model (LPM) with variable ejector component efficiencies provided by CFD simulations. The CFD results are used for developing maps for ejector component efficiencies in a broad range of operating conditions. The ejector component efficiency maps couple the CFD and the LPM techniques for building an Integrated LPM-CFD approach. The proposed approach is demonstrated for a convergent nozzle ejector and the paper is structured in four parts. At first, the CFD approach is validated by global and local data and seven Reynolds Averaged Navier Stokes (RANS) turbulence models are compared: the k-omega SST showed good performance and was selected for the rest of the analysis. At second, a Lumped Parameter Model (LPM) for subsonic ejector is developed and the ejector component efficiencies have been defined. At third, the CFD approach is used to investigate the flow field, to analyze its influence on ejector component efficiencies and to propose efficiency correlations and maps linking ejector component efficiencies and local flow quantities. In the last part, the efficiency maps are embedded into the lumped parameter model, thus creating the Integrated LPM-CFD (ILPM-CFD) model. The ILPM-CFD model is validated over experimental and CFD data and is compared with LPM Constant Efficiency models showing better performance and a wider range of applicability. The average deviation between the ILPM-CFD results and the experimental and CFD data is less than 0.75%, whereas constant efficiency models showed a deviation up to 30%. The ILPM-CFD model is able to vary the value of the ejector component efficiencies depending on the operating condition, being able to evaluate both the on-design and off-design performance of the ejector. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:697 / 715
页数:19
相关论文
共 80 条
[1]   Temperature corrected turbulence model for high temperature jet flow [J].
Abdol-Hamid, KS ;
Pao, SP ;
Massey, SJ ;
Elmiligui, A .
JOURNAL OF FLUIDS ENGINEERING-TRANSACTIONS OF THE ASME, 2004, 126 (05) :844-850
[2]   A verification study of steam-ejector refrigeration model [J].
Alexis, GK ;
Rogdakis, ED .
APPLIED THERMAL ENGINEERING, 2003, 23 (01) :29-36
[3]   Modelling and simulation of steam jet ejectors [J].
Aly, NH ;
Karameldin, A ;
Shamloul, MM .
DESALINATION, 1999, 123 (01) :1-8
[4]  
[Anonymous], 2011, WORLD ACAD SCI ENG T
[5]  
Ansys FLUENT 13, 2010, ANS FLULENT 13 THEOR
[6]   A CFD-based investigation of the energy performance of two-phase R744 ejectors to recover the expansion work in refrigeration systems: An irreversibility analysis [J].
Banasiak, Krzysztof ;
Palacz, Michal ;
Hafner, Armin ;
Bulinski, Zbigniew ;
Smolka, Jacek ;
Nowak, Andrzej J. ;
Fic, Adam .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2014, 40 :328-337
[7]   Numerical assessment of ejector operation for refrigeration applications based on CFD [J].
Bartosiewicz, Y ;
Aidoun, Z ;
Mercadier, Y .
APPLIED THERMAL ENGINEERING, 2006, 26 (5-6) :604-612
[8]  
Bartosiewicz Y., 2003, P INT CFD EXP, V26, P71
[9]  
Besagni G, 2015, INT J REFRIG
[10]  
Besagni G, 2014, ASME 2014 12 BIENN C