The ultimate soft-shell technique compartmentalizes the anterior chamber using the ultimate low-viscosity fluid-water (as balanced salt solution [BSS(R)] or trypan blue [Vision Blue(R)])-in combination with 1 of 2 commercially available viscoadaptive ophthalmic viscosurgical devices: Healon(R)5 (sodium hyaluronate 2.3%) or I-Visc(R) Phaco (sodium hyaluronate 2.5%). The use of this technique facilitates cataract surgery with viscoadaptive OVDs and viscoadaptive removal at the end of the procedure.