Nonlinear, seismic response spectra of smart sliding isolated structures with independently variable MR dampers and variable stiffness SAIVS system

被引:8
|
作者
Nagarajaiah, Satish [1 ]
Mao, Yuqing
Saharabudhe, Sanjay
机构
[1] Rice Univ, Dept Civil & Env Eng & Mech Eng & Mat Sci, Houston, TX 77005 USA
[2] Mentor Subsea Engn, Houston, TX 77079 USA
[3] J Ray McDermott Engn LLC, Houston, TX 77079 USA
关键词
semiactive structural control; sliding isolated structure; seismic response; variable MR dampers; variable stiffness device; nonlinear response spectra;
D O I
10.12989/sem.2006.24.3.375
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Under high velocity, pulse type near source earthquakes semi-active control systems are very effective in reducing seismic response base isolated structures. Semi-active control systems can be classified as: 1) independently variable stiffiess, 2) independently variable damping, and 3) combined variable stiffiess and damping systems. Several researchers have studied the effectiveness of independently varying damping systems for seismic response reduction of base isolated structures. In this study effectiveness of a combined system consisting of a semi-active independently variable stiffness (SAIVS) device and a magnetorheological (MR) damper in reducing seismic response of base isolated structures is analytically investigated. The SAIVS device can vary the stiffness, and hence the period, of the isolation system; whereas, the MR damper enhances the energy dissipation characteristics of the isolation system. Two separate control algorithms, i.e., a nonlinear tangential stiffiess moving average control algorithm for smooth switching of the SAWS device and a Lyapunov based control algorithm for damping variation of MR damper, are developed. Single and multi degree of freedom systems consisting of sliding base isolation system and both the SAWS device and MR damper are considered. Results are presented in the form of nonlinear response spectra, and effectiveness of combined variable stiffness and variable damping system in reducing seismic response of sliding base isolated structures is evaluated. It is shown that the combined variable stiffness and variable damping system leads to significant response reduction over cases with variable stiffness or variable damping systems acting independently, over a broad period range.
引用
收藏
页码:375 / 393
页数:19
相关论文
共 20 条
  • [1] Seismic response control of nonlinear base isolated structures using variable fluid dampers
    Wongprasert, N
    Symans, MD
    SMART STRUCTURES AND MATERIALS 2001: SMART SYSTEMS FOR BRIDGES, STRUCTURES, AND HIGHWAYS, 2001, 4330 : 333 - 344
  • [2] Seismic response of sliding isolated bridges with MR dampers
    Nagarajaiah, S
    Sahasrabudhe, S
    Iyer, R
    PROCEEDINGS OF THE 2000 AMERICAN CONTROL CONFERENCE, VOLS 1-6, 2000, : 4437 - 4441
  • [3] Seismic response control of smart sliding isolated buildings using variable stiffness systems: An experimental and numerical study
    Nagarajaiah, S
    Sahasrabudhe, S
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2006, 35 (02): : 177 - 197
  • [4] Seismic Protection of Structures Using Tuned Mass Dampers with Resettable Variable Stiffness
    Lin, Chi-Chang
    Soong, Tsu T.
    EMBODYING INTELLIGENCE IN STRUCTURES AND INTEGRATED SYSTEMS, 2013, 83 : 75 - +
  • [5] SEISMIC RESPONSE CONTROLLED STRUCTURE WITH ACTIVE VARIABLE STIFFNESS SYSTEM
    KOBORI, T
    TAKAHASHI, M
    NASU, T
    NIWA, N
    OGASAWARA, K
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 1993, 22 (11): : 925 - 941
  • [6] Seismic response controlled structure with active variable stiffness system
    Kobori, Takuji
    Takahashi, Motoichi
    Nasu, Tadashi
    Niwa, Naoki
    Ogasawara, Katsura
    Earthquake Engineering and Structural Dynamics, 1993, 22 (11) : 925 - 941
  • [7] Seismic Response of Structures with Variable Friction Pendulum System
    Panchal, V. R.
    Jangid, R. S.
    JOURNAL OF EARTHQUAKE ENGINEERING, 2009, 13 (02) : 193 - 216
  • [8] Seismic Response of Torsionally Coupled System with Semi-Active Variable Dampers
    Mevada, Snehal V.
    Jangid, R. S.
    JOURNAL OF EARTHQUAKE ENGINEERING, 2012, 16 (07) : 1043 - 1054
  • [9] Seismic Response of Adjacent Structures Connected with Semi-Active Variable Friction Dampers
    Patel, Chiragbhai Chandubhai
    Jangid, Radhey Shyam
    INTERNATIONAL JOURNAL OF ACOUSTICS AND VIBRATION, 2010, 15 (01): : 39 - 46
  • [10] Seismic Response of Base-Isolated Benchmark Building with Variable Sliding Isolators
    Sharma, Ajay
    Jangid, R. S.
    JOURNAL OF EARTHQUAKE ENGINEERING, 2010, 14 (07) : 1063 - 1091