The effect of surface treatments of nickel-titanium files on wear and cutting efficiency

被引:62
作者
Rapisarda, E
Bonaccorso, A
Tripi, TR
Fragalk, I
Condorelli, GG
机构
[1] Univ Catania, Cattedra Odontoiatria Conservatr, Corso Laurea Odontoiatria & Protesi Dent, I-95128 Catania, Italy
[2] Univ Catania, Dipartimento Sci Chim, I-95125 Catania, Italy
来源
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS | 2000年 / 89卷 / 03期
关键词
D O I
10.1016/S1079-2104(00)70103-X
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives. This study was designed to verify whether nitridation treatment of the cutting surfaces resulted in surface or subsurface changes that produced an increase in the resistance to wear in nickel titanium (NiTi) endodontic files. Study design. Some experimental samples were exposed to ionic implantation by using 150 keV of nitrogen ions and doses of 1 x 10(17) ions per cm(2). Other samples were exposed to thermal nitridation processes performed for 480 minutes at 500 degrees C temperature. Control samples were not exposed to any process. The chemical composition of the surface layers of each sample was determined by means of x-ray photoelectron spectroscopy. The cutting efficiency was tested on an endotraining bloc. Results. The experimental instruments showed in-depth distributions of chemical composition that were different from those seen in the control group; thermal-nitridated instruments demonstrated a surface ratio of nickel to titanium of 0.5. Implanted samples had a higher N/Ti ratio (1.2); this ratio may be due to the presence of a layer of titanium nitride. Samples in the experimental groups showed an increase in cutting ability as compared with the controls. Conclusions. Thermal nitridation and nitrogen-ionic implantation treatment of nickel-titanium files produced a higher wear resistance and an increased cutting capacity.
引用
收藏
页码:363 / 368
页数:6
相关论文
共 16 条
[1]  
BRANDING HJ, 1992, NUCL INSTRUMENTS MET, V66, P230
[2]  
BRIGGS D, 1995, PRACTICAL SURFACE AN, V1
[3]  
CANTATORE G, 1996, DENT CADMOS, V2, P11
[4]  
Gambarini G, 1998, GIORNALE ITALIANO EN, V1, P17
[5]   Comparison of nickel-titanium and stainless steel hand-file instrumentation using computed tomography [J].
Gambill, JM ;
Alder, M ;
delRio, CE .
JOURNAL OF ENDODONTICS, 1996, 22 (07) :369-375
[6]   A COMPARISON OF ROOT-CANAL PREPARATIONS USING NI-TI HAND, NI-TI ENGINE-DRIVEN, AND K-FLEX ENDODONTIC INSTRUMENTS [J].
GLOSSON, CR ;
HALLER, RH ;
DOVE, SB ;
DELRIO, CE .
JOURNAL OF ENDODONTICS, 1995, 21 (03) :146-151
[7]   Enhanced surface hardness by boron implantation in nitinol alloy [J].
Lee, DH ;
Park, B ;
Saxena, A ;
Serene, TP .
JOURNAL OF ENDODONTICS, 1996, 22 (10) :543-546
[8]  
MALAGNINO VA, 1994, GIORNALE ITALIANO EN, V6, P10
[9]   Effect of sterilization on the cutting efficiency of rotary nickel-titanium endodontic files [J].
Rapisarda, E ;
Bonaccorso, A ;
Tripi, TR ;
Condorelli, GG .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1999, 88 (03) :343-347
[10]  
RAPISARDA E, 1998, GIORNALE ITALIANO EN, V3, P144