Capillary ultrahigh-pressure liquid chromatography-mass spectrometry for fast and high resolution metabolomics separations

被引:16
|
作者
Sorensen, Matthew J. [1 ]
Kennedy, Robert T. [1 ,2 ]
机构
[1] Univ Michigan, Dept Chem, Ann Arbor, MI 48109 USA
[2] Univ Michigan, Dept Pharmacol, Ann Arbor, MI 48109 USA
基金
美国国家科学基金会;
关键词
ultrahigh-pressure liquid chromatography; mass spectrometry; metabolomics; peak capacity; sub-2 micron particles; PEAK-CAPACITY; SLURRY CONCENTRATION; HIGH-EFFICIENCY; MICRODIALYSIS SAMPLES; RPLC SEPARATIONS; SLIP-FLOW; UPLC-MS; PARTICLES; COLUMNS; PERFORMANCE;
D O I
10.1016/j.chroma.2020.461706
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
LC-MS is an important tool for metabolomics due its high sensitivity and broad metabolite coverage. The goal of improving resolution and decreasing analysis time in HPLC has led to the use of 5 - 15 cm long columns packed with 1.7 - 1.9 mu m particles requiring pressures of 8 - 12 kpsi. We report on the potential for capillary LC-MS based metabolomics utilizing porous C18 particles down to 1.1 mu m diameter and columns up to 50 cm long with an operating pressure of 35 kpsi. Our experiments show that it is possible to pack columns with 1.1 mu m porous particles to provide predicted improvements in separation time and efficiency. Using kinetic plots to guide the choice of column length and particle size, we packed 50 cm long columns with 1.7 mu m particles and 20 cm long columns with 1.1 mu m particles, which should produce equivalent performance in shorter times. Columns were tested by performing isocratic and gradient LC-MS analyses of small molecule metabolites and extracts from plasma. These columns provided approximately 100,000 theoretical plates for metabolite standards and peak capacities over 500 in 100 min for a complex plasma extract with robust interfacing to MS. To generate a given peak capacity, the 1.1 mu m particles in 20 cm columns required roughly 75% of the time as 1.7 mu m particles in 50 cm columns with both operated at 35 kpsi. The 1.1 mu m particle packed columns generated a given peak capacity nearly 3 times faster than 1.7 mu m particles in 15 cm columns operated at similar to 10 kpsi. This latter condition represents commercial state of the art for capillary LC. To consider practical benefits for metabolomics, the effect of different LC-MS variables on mass spectral feature detection was evaluated. Lower flow rates (down to 700 nL/min) and larger injection volumes (up to 1 mu L) increased the features detected with modest loss in separation performance. The results demonstrate the potential for fast and high resolution separations for metabolomics using 1.1 mu m particles operated at 35 kpsi for capillary LC-MS. (C) 2020 Elsevier B.V. All rights reserved.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Determination of coumestrol in lucerne by ultra-high pressure liquid chromatography-mass spectrometry
    Taujenis, Lukas
    Padarauskas, Audrius
    Ceseviciene, Jurgita
    Lemeziene, Nijole
    Butkute, Bronislava
    CHEMIJA, 2016, 27 (01): : 60 - 64
  • [32] Ultrahigh-Pressure Liquid Chromatography-Quadrupole-Time-of-Flight Mass Spectrometry-Based Metabolomics Reveal the Mechanism of Methyl Jasmonate in Delaying the Deterioration of Agaricus bisporus
    Yang, Wenjian
    Wu, Yuanyue
    Hu, Qiuhui
    Mariga, Alfred Mugambi
    Pei, Fei
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2019, 67 (32) : 8773 - 8782
  • [33] Plasma metabolomics analysis of the effects of drinking soda water on hyperglycemia mice using ultrahigh-pressure liquid chromatography-quadrupole-time of flight-mass spectrometry
    Han, Dan
    Shi, Litian
    Pan, Hongzhi
    BIOMEDICAL CHROMATOGRAPHY, 2021, 35 (04)
  • [34] Optimization of pretreatment methods for cerebrospinal fluid metabolomics based on ultrahigh performance liquid chromatography/mass spectrometry
    Song, Zhiqiang
    Wang, Mian
    Zhu, Zhenyu
    Tang, Gusheng
    Liu, Yue
    Chai, Yifeng
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2021, 197
  • [35] Derivatization for liquid chromatography-mass spectrometry
    Qi, Bao-Ling
    Liu, Ping
    Wang, Qiu-Yi
    Cai, Wen-Jing
    Yuan, Bi-Feng
    Feng, Yu-Qi
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2014, 59 : 121 - 132
  • [36] Application of Ultra Performance Liquid Chromatography-Mass Spectrometry to Profiling Rat and Dog Bile
    Plumb, Robert S.
    Rainville, Paul D.
    Potts, Warren B., III
    Johnson, Kelly A.
    Gika, Eleni
    Wilson, Ian D.
    JOURNAL OF PROTEOME RESEARCH, 2009, 8 (05) : 2495 - 2500
  • [37] Characterization of Ikaria Heather Honey by Untargeted Ultrahigh-Performance Liquid Chromatography-High Resolution Mass Spectrometry Metabolomics and Melissopalynological Analysis
    Kasiotis, Konstantinos M.
    Baira, Eirini
    Iosifidou, Styliani
    Bergele, Kyriaki
    Manea-Karga, Electra
    Theologidis, Ioannis
    Barmpouni, Theodora
    Tsipi, Despina
    Machera, Kyriaki
    FRONTIERS IN CHEMISTRY, 2022, 10
  • [38] Characterization and Comparison of Wine Lees by Liquid Chromatography-Mass Spectrometry in High-Resolution Mode
    Delgado de la Torre, M. P.
    Priego-Capote, F.
    Luque de Castro, M. D.
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2015, 63 (04) : 1116 - 1125
  • [39] Ultrahigh-Pressure Liquid Chromatography, Part III: Potential Issues
    Dong, Michael W.
    LC GC NORTH AMERICA, 2017, 35 (11) : 818 - 823
  • [40] Ultrahigh-Pressure Liquid Chromatography, Part 3: Potential Issues
    Gong, Michael W.
    LC GC EUROPE, 2017, 30 (10) : 563 - 569